Diffusion of phenolic compounds through two high-density polyethylene geomembranes after 17 years under different exposure conditions
Source abstract
Abstract
This paper presents the results of an experimental study of diffusion of 2,4,6-trichlorophenol, 2,3,5,6-tetrachlorophenol, and pentachlorophenol through two 17-year-old high-density polyethylene geomembranes (HDPE GMs): the first was stored indoors away from direct sunlight whereas the second was exposed for the entire time in a south-facing corner of a pond. Both unexposed and exposed specimens, although under different exposure conditions, experienced ageing. Partition coefficients ranged from 30 to 190, increasing with the number of chlorine atoms in the contaminant. Diffusion coefficients for the unexposed geomembrane ranged from 9 × 10−14 to 2.4 × 10−13 m2/s and from 9 × 10−14 to 2.8 × 10−13 m2/s for the exposed geomembrane. These values were compared with those reported in the literature for diffusion of the same phenolic compounds through a virgin HDPE geomembrane from a different manufacturer: the exposure did not noticeably affect the partition coefficients or diffusion coefficients. This result was linked to the temporal evolution of the unexposed geomembrane. Furthermore, in spite of their 17-year ageing, both geomembrane specimens still had diffusive characteristics that were consistent with a virgin geomembrane obtained from a different manufacturer.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Landfill Environmental Impact Studies · Electrokinetic Soil Remediation Techniques · Recycled Aggregate Concrete Performance
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Hydrosystems and Bioprocesses Research Unit, Irstea, Antony, France, Telephone: +33 140966039; Telefax: +33 140966270;
Arcadis, Marseille, France, Telephone: +33 658723647;
Département Matériaux, IFSTTAR, Champs-sur-Marne, France, Telephone: +33 181668414; Telefax: +33 181668514;
Hydrosystems and Bioprocesses Research Unit, Irstea, Antony, France, Telephone: +33 140966061; Telefax: +33 140966270;
References (68)
Show source-provided references
1. AFNOR · 2005
2. 10.1007/s00128000012010.1007/s001280000120 ↗
3. Baldauf S. · 2012 · 5 · 57
4. 10.1016/S0269-7491(99)00173-610.1016/S0269-7491(99)00173-6 ↗
5. 10.1016/S0048-9697(97)00272-610.1016/S0048-9697(97)00272-6 ↗
6. 10.1016/j.watres.2004.07.00610.1016/j.watres.2004.07.006 ↗
7. 10.1016/S0045-6535(00)00458-610.1016/S0045-6535(00)00458-6 ↗
8. Brandsch J. · 1999 · 27
9. 10.1016/S0883-2927(00)00082-210.1016/S0883-2927(00)00082-2 ↗
10. 10.1080/1080-70029190584610.1080/1080-700291905846 ↗
11. 10.1061/9780784413272.19210.1061/9780784413272.192 ↗
12. Gron C. · Water, Air, and Soil Pollution · 1999 · 120 · 331
13. 10.1016/0043-1354(83)90239-710.1016/0043-1354(83)90239-7 ↗
14. 10.1016/S0924-2244(02)00031-610.1016/S0924-2244(02)00031-6 ↗
15. Hiroshi A. · 2002 · 728
16. Hoekstra H. D. · Polymer Degradation and Stability · 1995 · 81 · 367
17. Islam M. Z. · 2008 · 459
18. 10.1061/(ASCE)GT.1943-5606.000005610.1061/(ASCE)GT.1943-5606.0000056 ↗
19. 10.1080/1064338029081346210.1080/10643380290813462 ↗
20. 10.1016/S0304-3894(01)00365-X10.1016/S0304-3894(01)00365-X ↗
21. 10.1016/S0011-9164(04)90202-010.1016/S0011-9164(04)90202-0 ↗
22. 10.1016/S0021-9673(98)00075-210.1016/S0021-9673(98)00075-2 ↗
23. 10.1080/0306731090326730710.1080/03067310903267307 ↗
24. 10.1680/gein.2009.16.6.46810.1680/gein.2009.16.6.468 ↗
25. 10.1061/(ASCE)GT.1943-5606.000034510.1061/(ASCE)GT.1943-5606.0000345 ↗
26. 10.1680/gein.14.0000510.1680/gein.14.00005 ↗
27. Müller W. · 1998 · 1 · 239
28. 10.1016/j.colsurfa.2003.09.02610.1016/j.colsurfa.2003.09.026 ↗
29. 10.1016/j.geotexmem.2006.12.00210.1016/j.geotexmem.2006.12.002 ↗
30. 10.1016/j.chemosphere.2007.10.05510.1016/j.chemosphere.2007.10.055 ↗
31. Nininen M. · 1994 · 64
32. 10.1016/0269-7491(93)90047-R10.1016/0269-7491(93)90047-R ↗
33. 10.1016/j.cej.2005.02.03310.1016/j.cej.2005.02.033 ↗
34. 10.1016/j.jhazmat.2005.04.01610.1016/j.jhazmat.2005.04.016 ↗
35. 10.2175/WER.65.3.610.2175/WER.65.3.6 ↗
36. 10.1016/j.geotexmem.2011.09.00110.1016/j.geotexmem.2011.09.001 ↗
37. 10.2166/wst.2000.058510.2166/wst.2000.0585 ↗
38. Pons, C. (2012). Durabilité des Geomembranes en Polyethylene Haute Densité Utilisées dans les Installations de Stockage de Déchets Non Dangereux, PhD theis, Universtité Paris Est, Champs sur Marne, France.
39. 10.1177/0734242X940120010710.1177/0734242X9401200107 ↗
40. Ramamoorthy S. · 1997
41. 10.1021/es00130a01110.1021/es00130a011 ↗
42. 10.1016/S0021-9673(02)01098-110.1016/S0021-9673(02)01098-1 ↗
43. 10.1016/S0021-9673(02)01280-310.1016/S0021-9673(02)01280-3 ↗
44. 10.1016/j.clay.2006.11.00610.1016/j.clay.2006.11.006 ↗
45. Robinson H. D. · 2001 · 21
46. Rowe R. K. · 1997
47. 10.1680/gein.2.002110.1680/gein.2.0021 ↗
48. 10.1139/t03-01910.1139/t03-019 ↗
49. 10.1016/S0266-1144(01)00013-910.1016/S0266-1144(01)00013-9 ↗
50. 10.1061/(ASCE)1090-0241(2005)131:6(694)10.1061/(ASCE)1090-0241(2005)131:6(694) ↗
51. 10.2134/jeq1984.00472425001300030005x10.2134/jeq1984.00472425001300030005x ↗
52. 10.1007/BF0047835110.1007/BF00478351 ↗
53. 10.1016/S0043-1354(01)00452-310.1016/S0043-1354(01)00452-3 ↗
54. 10.1007/s00128991001710.1007/s001289910017 ↗
55. 10.1016/j.scitotenv.2004.07.00210.1016/j.scitotenv.2004.07.002 ↗
56. 10.1016/S0045-6535(97)10133-310.1016/S0045-6535(97)10133-3 ↗
57. 10.1016/S0956-053X(01)00071-X10.1016/S0956-053X(01)00071-X ↗
58. 10.1061/41165(397)11510.1061/41165(397)115 ↗
59. Touze-Foltz N. · Journal of Geotechnical Engineering, South East Asia Geotechnical Engineering Society · 2012 · 43 · 19
60. Touze-Foltz N. · Inernational Journal of Geosynthetics and Ground Engineering · 2015 · 43 · 1
61. Van Praagh M. · 2011
62. 10.1016/S0304-3894(97)00062-910.1016/S0304-3894(97)00062-9 ↗
63. 10.1007/BFb005102910.1007/BFb0051029 ↗
64. 10.2965/jswe.22.4010.2965/jswe.22.40 ↗
65. 10.1016/S0045-6535(00)00079-510.1016/S0045-6535(00)00079-5 ↗
66. 10.1016/S0021-9673(97)00078-210.1016/S0021-9673(97)00078-2 ↗
67. 10.1177/0734242X990170030410.1177/0734242X9901700304 ↗
68. 10.1007/BF0291019410.1007/BF02910194 ↗