Novel green roofing membrane system made with recycled leftover paint
Source abstract
Abstract
Leftover paint is considered as a hazardous material and is associated with costly disposal around the world. In this study, a novel green roofing membrane system having a primered composite overlay incorporating leftover paint was developed and experimentally evaluated. Its performance was compared with that of more conventional low-slope roofing systems. The experimental program included static puncture, dynamic impact, peeling, pull-off and exposure to fire testing. Two series of specimens were tested: unaged specimens cured at normal conditions and accelerated-aged specimens exposed to cold and arid conditions for different time periods. Results indicated that the primered composite overlay significantly improved the static puncture resistance, dynamic impact performance and fire resistance. The peeling and pull-off test results mainly depended on the method of installation for the single-ply membranes. The fully adhered system showed best performance. The exposure condition did not induce significant changes in measured properties by the end of the investigated period. It is demonstrated that beneficiating leftover paint in producing roofing systems can consume large volumes of this hazardous waste, yielding significant economic and environmental benefits and enhanced roofing membranes.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Urban Stormwater Management Solutions · Flame retardant materials and properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Professor, Department of Civil and Environmental Engineering, Western University, London, ON, Canada
Postdoctoral Fellow, Department of Civil and Environmental Engineering, Western University, London, ON, Canada
References (19)
Show source-provided references
1. Delgado A. H., Mukhopadhyaya P., Normandin N., Paroli R. M. Characteristics of Membranes and Insulations Used for Low-Slope Roofs, 2005, NRC Institute for Research in Construction, Ottawa, 1–14.
2. Mehta M., Scarborough W., Armpreiest D. Building Construction-Principles, Materials, and Systems. 2008, Pearson Prentice Hall, Ohio, 817–877.
3. Griffin C. W., Fricklas R. L. Manual of Low-Slope Roof Systems, 2006, 4th edn, McGraw-Hill Professional, New York: 598.
4. Garcia R. Consider Below the Membrane, 2008, Roofing Contractor, Troy, 46–49.
5. 10.1016/0142-9418(93)90025-K10.1016/0142-9418(93)90025-K ↗
6. Paroli R. M., Dutt O. M., Frégeau C. Properties and performance of roof coverings, 1997, NRC Institute for Research in Construction, Ottawa, 1–30.
7. Quiroz O. I. Recycling Waste Latex Paint in Overlays, Rigid Pavements, and Pervious Concrete (master thesis), 2011, University of Nevada, Las Vegas: 108.
8. Mohammed A. · ACI Materials Journal · 2008 · 105 · 367
9. Greiner T., Velva V., Phipps A. A background report for the national dialogue on paint product Stewardship, 2004, University of Massachusetts, Boston: 57.
10. ASTM D1349-09. Standard Practice for Rubber-Standard Temperatures for Testing, 2009, Vol. 09–01, American Society of Testing and Materials, West Conshohocken: 2.
11. ASTM D5602/D5602M-11. Standard Test Method for Static Puncture Resistance of Roofing Membrane Specimens, 2011, Vol. 04–04, American Society of Testing and Materials, West Conshohocken: 3.
12. ASTM D5635/D5635M-11. Standard Test Method for Dynamic Puncture Resistance of Roofing Membrane Specimens, 2011, Vol. 04–04, American Society of Testing and Materials, West Conshohocken: 5.
13. ASTM D1876-08. Standard Test Method for Peel Resistance of Adhesives (T-Peel Test), 2008, Vol. 15–06, American Society of Testing and Materials, West Conshohocken: 3.
14. Brian D. · 1995 · 49
15. Mines R. A. · 1998 · 287
16. 10.1016/S0020-7683(99)00277-210.1016/S0020-7683(99)00277-2 ↗
17. 10.1016/j.compstruct.2004.09.01910.1016/j.compstruct.2004.09.019 ↗
18. Akil H. The impact response of composite sandwich structure (PhD Thesis), 2002, University of Liverpool, Liverpool: 240.