Nasolacrimal stent with shape memory as an advanced alternative to silicone products
Source abstract
Abstract
Epiphora is the overflow of tears typically caused by obstruction or occlusion of the nasolacrimal duct. More attention is required to address this global health issue owing to the increase in air pollution. Implantation of a silicone stent is the preferred treatment for epiphora; however, introducing a silicone stent into a narrow duct with complex geometry is challenging as it requires guidance by a sharp metal needle. Additionally, silicone can cause adverse reactions such as biofilm formation and tear flow resistance due to its extreme hydrophobicity. To overcome these problems, in this study we developed a new type of biocompatible shape memory polymer (SMP) stent with elasticity capacity for self-expansion. First, SMPs in the form of x%poly(ε-caprolactone)-co-y%poly(glycidyl methacrylate) (x%PCL-y%PGMA) were synthesized via ring opening polymerization by varying the molar ratio of PCL (x%) and PGMA (y%). Second, the shape memory and mechanical properties were tuned by controlling the crosslinking degree and concentration of x%PCL-y%PGMA solution to produce a test type of SMP stent. Lastly, this 94%PCL-06%PGMA stent exhibited more standout critical functions in a series of in vitro and in vivo experiments such as a cell growth-supporting level of biocompatibility with nasal epithelial cells without significant inflammatory responses, better resistance to biofilm formation, and more efficient capacity to drain tear than the silicone control. Overall, 94%PCL-06%PGMA can be suggested as a superior alternative to the currently used materials for nasolacrimal stents. STATEMENT OF SIGNIFICANCE: Silicone intubation (stenting) has been widely used to treat nasolacrimal duct obstruction, however, it can cause adverse clinical effects such as bacterial infection; presents procedural challenges because of the curved nasolacrimal duct structure; and shows poor drainage efficiency stemming from the highly hydrophobic nature of silicone. In this work, we describe an innovative shape memory polymer (SMP) as a superior alternative to conventional silicone-based materials for nasolacrimal duct intubation. We demonstrate the clear advantages of the SMP over conventional silicone, including a much higher drainage capacity and superior resistance to bacterial infection.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Nasolacrimal Duct Obstruction Treatments · Ocular Surface and Contact Lens · Corneal Surgery and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (55)
Show source-provided references
1. Silicone biomaterials: history and chemistry
2. Review on rubbers in medicine: natural, silicone and polyurethane rubbers, plastics10.1179/1743289811Y.0000000063 ↗
3. Biodeterioration of medical-grade silicone rubber used for voice prostheses: a sem study10.1016/0142-9612(93)90149-V ↗
4. Biocompatibility of silicone implants10.1097/00000637-198307000-00006 ↗
5. Inhibition of escherichia coli and proteus mirabilis adhesion and biofilm formation on medical grade silicone surface10.1002/bit.23342 ↗
6. Influence of surface properties on the adhesion of staphylococcus epidermidis to acrylic and silicone10.1155/2009/718017 ↗
7. Microbial biofilms: their development and significance for medical device—related infections10.1177/00912709922008506 ↗
8. Biofilm formation: a clinically relevant microbiological process10.1086/322972 ↗
9. Surface modification of silicone for biomedical applications requiring long-term antibacterial, antifouling, and hemocompatible properties10.1021/la303438t ↗
10. Hydrophobic recovery of repeatedly plasma-treated silicone rubber. Part 1. storage in air10.1163/156856195X01030 ↗
11. Acquired nasolacrimal duct obstruction10.1016/j.otc.2006.07.002 ↗
12. Etiology, diagnosis, management and outcomes of epiphora referrals to an oculoplastic practice
13. Primary acquired nasolacrimal duct obstruction: a clinicopathologic report and biopsy technique10.1016/S0161-6420(86)33620-0 ↗
14. A new, wider-diameter crawford tube for stenting in the lacrimal drainage system10.1097/01.IOP.0000103008.01277.BE ↗
15. Nasolacrimal duct obstruction treated nonsurgically with use of plastic stents10.1148/radiology.190.2.8284412 ↗
16. Silicone intubation for obstruction of the nasolacrimal duct in children10.1016/0002-9394(82)90001-0 ↗
17. Lacrimal stents and intubation systems: an insight
18. Study of microbial growth on silicone tubes after transcanalicular laser-assisted dacryocystorhinostomy and correlation with patency
19. Comparison of surgical outcomes in primary endoscopic dacryocystorhinostomy with and without silicone intubation, annals of otology10.1177/000348940211100809 ↗
20. Management of strictures of the lacrimal canaliculi with polyethylene tubes10.1001/archopht.1950.00910020203002 ↗
21. Malleable rods for immediate repair of the traumatically severed lacrimal canaliculus
22. Intubation of the lacrimal passages10.1016/0002-9394(68)91031-3 ↗
23. Does the timing of silicone tube removal following external dacryocystorhinostomy affect patients' symptoms?10.1080/01676830802674342 ↗
24. Microbiology and biofilm trends of silicone lacrimal implants: comparing infected versus routinely removed stents10.1097/IOP.0000000000000590 ↗
25. Thermodynamics of fusion of poly-β-propiolactone and poly-ϵ-caprolactone. comparative analysis of the melting of aliphatic polylactone and polyester chains10.1016/0014-3057(72)90109-7 ↗
26. Pendant allyl crosslinking as a tunable shape memory actuator for vascular applications10.1016/j.actbio.2015.06.004 ↗
27. Reduced time as a unified parameter determining fixity and free recovery of shape memory polymers10.1038/ncomms4066 ↗
28. Hydrophilic surface modification of poly(methyl methacrylate)-based ocular prostheses using poly(ethylene glycol) grafting10.1016/j.colsurfb.2017.07.017 ↗
29. Adherence of coagulase-negative staphylococci to plastic tissue culture plates: a quantitative model for the adherence of staphylococci to medical devices10.1128/jcm.22.6.996-1006.1985 ↗
30. Initiation of biofilm formation in pseudomonas fluorescens WCS365 proceeds via multiple, convergent signalling pathways: a genetic analysis10.1046/j.1365-2958.1998.00797.x ↗
31. Dacryocystography of normal and pathological lacrimal passages10.1136/bjo.53.3.174 ↗
32. MR dacryocystography in the evaluation of patients with obstructive epiphora treated by means of interventional radiologic procedures10.3174/ajnr.A2889 ↗
33. Simulation and experimental observation of contact conditions between stents and artery models10.1016/j.medengphy.2006.04.003 ↗
34. Development of a shape-memory tube to prevent vascular stenosis10.1002/adma.201904476 ↗
35. The effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis10.1016/j.biomaterials.2004.01.066 ↗
36. Reprint of: pendant allyl crosslinking as a tunable shape memory actuator for vascular applications10.1016/j.actbio.2016.03.021 ↗
37. Simultaneous dacryocystography and dacryoscintigraphy using spect/ct in the diagnosis of nasolacrimal duct obstruction10.1097/RLU.0b013e31824d2751 ↗
38. Nano-and sub-micron porous polyelectrolyte multilayer assemblies: biomimetic surfaces for human corneal epithelial cells10.1016/j.biomaterials.2009.03.020 ↗
39. A polycationic antimicrobial and biocompatible hydrogel with microbe membrane suctioning ability10.1038/nmat2915 ↗
40. Clinical significance of microbial growth on the surfaces of silicone tubes removed from dacryocystorhinostomy patients10.1016/j.ajo.2011.06.030 ↗
41. The microbiological spectrum and antibiotic sensitivity profile of extubated silicone stents following dacryocystorhinostomy10.3109/01676830.2013.815231 ↗
42. New insights into the pathophysiology of primary acquired dacryostenosis10.1016/S0161-6420(01)00946-0 ↗
43. Chronic dacryocystitis: its causation and treatment10.1001/archopht.1941.00870140015001 ↗
44. Scanning electron microscopic features of extubated monoka stents10.1097/IOP.0000000000000610 ↗
45. Scanning electron microscopic features of nasolacrimal silastic stents retained for prolong durations following dacryocystorhinostomy10.1097/IOP.0000000000000395 ↗
46. Electron microscopic features of intraluminal portion of nasolacrimal silastic stents following dacryocystorhinostomy: is there a need for stents without a lumen?10.1097/IOP.0000000000000482 ↗
47. Indications, complications and results with silicone stents10.1016/S0161-6420(79)35374-X ↗
48. Predictors of silicone tube intubation success in patients with lacrimal drainage system stenosis10.3341/kjo.2016.30.3.157 ↗
49. The outcome of silicone intubation and tube removal in external dacryocystorhinostomy patients with distal canalicular obstruction10.5301/ejo.5000128 ↗
50. Biofilm quantification on nasolacrimal silastic stents after dacryocystorhinostomy10.1097/IOP.0000000000000361 ↗
51. Double silicone intubation as treatment for persistent congenital nasolacrimal duct obstruction10.1097/01.IOP.0000103004.71978.0C ↗
52. Nonsurgical placement of a nasolacrimal polyurethane stent: long-term effectiveness10.1148/radiology.200.3.8756928 ↗
53. Evaluation of polyurethane nasolacrimal duct stents: in vivo studies in new zealand rabbits10.1007/s00270-005-0232-8 ↗
54. Nasolacrimal polyurethane stent placement for epiphora: technical long-term results10.1016/S1051-0443(07)61406-7 ↗
55. Clinical efficacy of the polyurethane stent without fluoroscopic guidance in the treatment of nasolacrimal duct obstruction10.1016/S0161-6420(00)00225-6 ↗