Optimum sensitivities of D-type optical fiber sensor at a specific incident angle
Source abstract
Abstract
The optimum incident angle for a 4 mm long and 4 μm core thickness D-type optical fiber sensor in the intensity measurements is near at 89°. The sensitivity is higher than 40 (1/RIU) and its resolution is better than 2.5×10-5 RIU. This sensor is used to detect the refractive index or gas or liquid concentration in real-time, and it has some merits such as small, simple and inexpensive and provides an in vivo test.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Fiber Optic Sensors · Photonic and Optical Devices · Semiconductor Lasers and Optical Devices
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. U. Kunz, A. Katerkamp, R. Renneberg, F. Spener, K. Cammann, Sens. Actuators B 32, 149 (1996)10.1016/0925-4005(96)80124-9 ↗
2. A. Abdelghani, C. Veillas, J.M. Chovelon, N. Jaffrezic-Renault, H. Gagnaire, Synth. Met. 90, 193 (1997)10.1016/S0379-6779(98)80006-4 ↗
3. R. Slavik, J. Homola, E. Brynda, Biosens. Bioelectron. 17, 591 (2002)10.1016/S0956-5663(02)00013-1 ↗
4. M. Mitsushio, S. Higashi, M. Higo, Sens. Actuators A 111, 252 (2004)10.1016/j.sna.2003.11.029 ↗
5. E. Brynda, J. Homola, M. Houska, P. Pfeifer, J. Škvor, Sens. Actuators B 54, 132 (1999)10.1016/S0925-4005(98)00331-1 ↗
6. R. Slavik, J. Homola, J. Čtyroký, Sens. Actuators B 51, 311 (1998)10.1016/S0925-4005(98)00205-6 ↗
7. R. Slavik, J. Homola, J. Čtyroký, Sens. Actuators B 54, 74 (1999)10.1016/S0925-4005(98)00314-1 ↗
8. R. Slavik, J. Homola, J. Čtyroký, E. Brynda, Sens. Actuators B 74, 106 (2001)10.1016/S0925-4005(00)00718-8 ↗
9. M. Piliarik, J. Homola, Z. Maníková, J. Čtyroký, Sens. Actuators B 90, 236 (2003)10.1016/S0925-4005(03)00034-0 ↗
10. D. Monzón-Hernández, J. Villatoro, D. Talavera, D. Luna-Moreno, Appl. Opt. 43, 1216 (2004)10.1364/AO.43.001216 ↗
11. R.C. Jorgenson, Sens. Actuators B 73, 236 (2001)10.1016/S0925-4005(00)00690-0 ↗
12. E. Fontana, IEEE 50, 82 (2002)10.1109/22.981251 ↗
13. W.B. Lin, N. Jaffrezic-Renault, A. Gagnaire, H. Gagnaire, Sens. Actuators 84, 198 (2000)10.1016/S0924-4247(00)00345-9 ↗
14. M. Iga, A. Seki, K. Watanabe, Sens. Actuators B 101, 368 (2004)10.1016/j.snb.2004.04.007 ↗
15. K. Kurihara, H. Ohkawa, Y. Iwasaki, O. Niwa, T. Tobita, K. Suzuki, Anal. Chim. Acta 523, 165 (2004)10.1016/j.aca.2004.07.045 ↗
16. S.F. Wang M.H. Chiu, R.S. Chang, Opt. Eng. Lett. 44, 030502-1 (2005)
17. M.H. Chiu, S.F. Wang, R.S. Chang, Opt. Lett. 30, 233 (2005)10.1364/OL.30.000233 ↗
18. B.D. Gupta, A.K. Sharma, Sens. Actuators B 107, 40 (2005)10.1016/j.snb.2004.08.030 ↗
19. J. Villatoro, A. García-Valenzuela, Appl. Opt. 38, 4837 (1999)10.1364/AO.38.004837 ↗
20. J. Homola, Sens. Actuators B 41, 207 (1997)10.1016/S0925-4005(97)80297-3 ↗
21. R. Naraoka, K. Kajikawa, Sens. Actuators B 107, 952 (2005)10.1016/j.snb.2004.12.044 ↗
22. K.H. Chen, C.C. Hsu, D.C. Su, Opt. Commun. 209, 167 (2002)10.1016/S0030-4018(02)01641-3 ↗