Biodegradation-affected fatigue behavior of extrusion-based additively manufactured porous iron–manganese scaffolds
Source abstract
Abstract
Additively manufactured (AM) biodegradable porous iron-manganese (FeMn) alloys have recently been developed as promising bone-substituting biomaterials. However, their corrosion fatigue behavior has not yet been studied. Here, we present the first study on the corrosion fatigue behavior of an extrusion-based AM porous Fe35Mn alloy under cyclic loading in air and in the revised simulated body fluid (r-SBF), including the fatigue crack morphology and distribution in the porous structure. We hypothesized that the fatigue behavior of the architected AM Fe35Mn alloy would be strongly affected by the simultaneous biodegradation process. We defined the endurance limit as the maximum stress at which the scaffolds could undergo 3 million loading cycles without failure. The endurance limit of the scaffolds was determined to be 90% of their yield strength in air, but only 60% in r-SBF. No notable crack formation in the specimens tested in air was observed even after loading up to 90% of their yield strength. As for the specimens tested in r-SBF, however, cracks formed in the specimens subjected to loads exceeding 60% of their yield strength appeared to initiate on the periphery and propagate toward the internal struts. Altogether, the results show that the extrusion-based AM porous Fe35Mn alloy is capable of tolerating up to 60% of its yield strength for up to 3 million cycles, which corresponds to 1.5 years of use of load-bearing implants subjected to repetitive gait cycles. The fatigue performance of the alloy thus further enhances its potential for trabecular bone substitution subjected to cyclic compressive loading. Fatigue behavior of extrusion-based AM porous Fe35Mn alloy scaffolds in air and revised simulated body fluid was studied. The Fe35Mn alloy scaffolds endured 90% of their yield strength for up to 3×106 loading cycles in air. Moreover, the scaffolds tolerated 3×106 loading cycles at 60% of their yield strength in revised simulated body fluid. The Fe35Mn alloy scaffolds exhibited a capacity of withstanding 1.5-year physiological loading when used as bone implants.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Additive Manufacturing and 3D Printing Technologies · Bone Tissue Engineering Materials · Aluminum Alloys Composites Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (53)
Show source-provided references
1. Challenges in the use of Fe-based materials for bone scaffolds applications: perspective from in vivo biocorrosion
2. Biodegradable metallic bone implants10.1039/C8QM00507A ↗
3. Extrusion-based 3D printed biodegradable porous iron
4. Additively manufactured iron-manganese for biodegradable porous load-bearing bone scaffold applications10.1016/j.actbio.2019.12.018 ↗
5. Extrusion-based 3D printing of ex situ-alloyed highly biodegradable MRI-friendly porous iron-manganese scaffolds10.1016/j.actbio.2021.07.042 ↗
6. Selective laser melted Fe-Mn bone scaffold: Microstructure, corrosion behavior and cell response
7. In vitro and 48 weeks in vivo performances of 3D printed porous Fe-30Mn biodegradable scaffolds10.1016/j.actbio.2020.12.028 ↗
8. Biodegradable Fe-based alloys for use in osteosynthesis: Outcome of an in vivo study after 52 weeks10.1016/j.actbio.2014.04.007 ↗
9. In vitro and in vivo degradation evaluation of novel iron-bioceramic composites for bone implant applications10.1016/j.msec.2013.12.022 ↗
10. Extrusion-based 3D printing of biodegradable, osteogenic, paramagnetic, and porous FeMn-akermanite bone substitutes10.1016/j.actbio.2023.03.033 ↗
11. Additively manufactured biodegradable porous metals10.1016/j.actbio.2020.08.018 ↗
12. Relationship between unit cell type and porosity and the fatigue behavior of selective laser melted meta-biomaterials10.1016/j.jmbbm.2014.12.015 ↗
13. Fatigue performance of additively manufactured meta-biomaterials: the effects of topology and material type10.1016/j.actbio.2017.11.014 ↗
14. Additive manufacturing of biomaterials - design principles and their implementation10.3390/ma15155457 ↗
15. Corrosion fatigue behavior of additively manufactured biodegradable porous iron10.1016/j.corsci.2019.05.003 ↗
16. Biodegradation-affected fatigue behavior of additively manufactured porous magnesium
17. Corrosion fatigue behavior of additively manufactured biodegradable porous zinc10.1016/j.actbio.2020.02.001 ↗
18. Corrosion fatigue behavior and anti-fatigue mechanisms of an additively manufactured biodegradable zinc-magnesium gyroid scaffold10.1016/j.actbio.2022.09.047 ↗
19. Preparation and assessment of revised simulated body fluids10.1002/jbm.a.10482 ↗
20. Effects of scaffold architecture on cranial bone healing10.1016/j.ijom.2013.05.008 ↗
21. Scaffold curvature-mediated novel biomineralization process originates a continuous soft tissue-to-bone interface10.1016/j.actbio.2017.07.029 ↗
22. Iron-manganese: new class of metallic degradable biomaterials prepared by powder metallurgy10.1179/174329008X284868 ↗
23. BoneJ2 - refactoring established research software
24. Fatigue and quasi-static mechanical behavior of bio-degradable porous biomaterials based on magnesium alloys10.1002/jbm.a.36380 ↗
25. Yield strain behavior of trabecular bone10.1016/S0021-9290(98)00057-8 ↗
26. Dependence of yield strain of human trabecular bone on anatomic site10.1016/S0021-9290(01)00011-2 ↗
27. Defects in additive manufactured metals and their effect on fatigue performance: a state-of-the-art review10.1016/j.pmatsci.2020.100724 ↗
28. Effects of porosity on the mechanical properties of additively manufactured components: a critical review10.1088/2053-1591/abcc5d ↗
29. Fatigue behaviour of titanium scaffolds with hierarchical porosity produced by material extrusion additive manufacturing10.1016/j.matdes.2022.111453 ↗
30. Fatigue performance of auxetic meta-biomaterials10.1016/j.actbio.2021.03.015 ↗
31. Measurement and estimation of osteocyte mechanical strain10.1016/j.bone.2013.01.037 ↗
32. Bone tissue regeneration: the role of scaffold geometry10.1039/C4BM00291A ↗
33. How does scaffold porosity conduct bone tissue regeneration?10.1002/adem.202100463 ↗
34. Porous scaffolds for bone regeneration10.1016/j.jsamd.2020.01.007 ↗
35. I. Buj-Corral, A. Domínguez-Fernández, A. Gómez-Gejo, Effect of printing parameters on dimensional error and surface roughness obtained in direct ink writing (DIW) processes, Materials (Basel). 13 (2020) 2157. https://doi.org/10.3390/ma13092157.10.3390/ma13092157 ↗
36. Fatigue of additively manufactured 316L stainless steel: the influence of porosity and surface roughness10.1111/ffe.13077 ↗
37. Surface roughness effect of SLM and EBM Ti-6Al-4V on multiaxial high cycle fatigue10.1016/j.tafmec.2020.102581 ↗
38. The influence of additive manufacturing processing parameters on surface roughness and fatigue life10.1016/j.ijfatigue.2019.03.025 ↗
39. Surface nanoporosity has a greater influence on osteogenic and bacterial cell adhesion than crystallinity and wettability10.1016/j.apsusc.2018.03.150 ↗
40. The effects of combined micron-/submicron-scale surface roughness and nanoscale features on cell proliferation and differentiation10.1016/j.biomaterials.2011.01.029 ↗
41. Surface antibacterial properties enhanced through engineered textures and surface roughness: a review10.1016/j.colsurfb.2023.113584 ↗
42. Additively manufactured biodegradable porous iron10.1016/j.actbio.2018.07.011 ↗
43. Porous Ti6Al4V alloys with enhanced normalized fatigue strength for biomedical applications10.1016/j.msec.2015.11.074 ↗
44. A fatigue life analysis of small fragment screws10.1097/00005131-200109000-00006 ↗
45. Mechanical strength, fatigue life, and failure analysis of two prototypes and five conventional tibial locking screws10.1097/00005131-200211000-00004 ↗
46. Compressive fatigue behavior of human vertebral trabecular bone10.1016/j.jbiomech.2005.04.033 ↗
47. Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity10.1054/arth.2002.32699 ↗
48. The influence of osteoporosis in femoral fracture healing time10.1016/j.injury.2008.10.035 ↗
49. How does tissue regeneration influence the mechanical behavior of additively manufactured porous biomaterials?10.1016/j.jmbbm.2016.10.003 ↗
50. Compressive and fatigue behavior of beta-type titanium porous structures fabricated by electron beam melting10.1016/j.actamat.2016.12.052 ↗
51. Compression fatigue behavior of Ti-6Al-4V mesh arrays fabricated by electron beam melting10.1016/j.actamat.2011.10.051 ↗
52. Compression–compression fatigue behaviour of gyroid-type triply periodic minimal surface porous structures fabricated by selective laser melting10.1016/j.actamat.2019.09.042 ↗
53. Chemical and electrochemical conditions within stress corrosion and corrosion fatigue cracks10.1038/s41529-017-0015-0 ↗