Evaluation of the particle release of porous PMMA cements during curing
Source abstract
Abstract
Poly(methyl methacrylate) (PMMA) remains the most common bone substitute material used for vertebroplasty. A possible downside with this material is that the Young's modulus of the cement is significantly higher than that of osteoporotic vertebral cancellous bone. In consequence, an increased fracture risk has been demonstrated for the adjacent vertebral bodies after reinforcement. A solution could be to prepare porous bone cements with a lower bulk modulus as suggested by De Wijn (De Wijn JR. Poly(methyl methacrylate)-aqueous phase blends: in situ curing porous materials. J Biomed Mater Res 1976;10:625-35). The potential of such porous PMMA cements for application in vertebroplasty has been shown in the literature. The present study was performed to study the release of particles, e.g. powder particles such as barium sulfate or hydroxyapatite, from PMMA cements containing an aqueous phase. The aqueous phase was introduced to act as a pore-forming phase to soften the cement and is thought to be released when applied in vivo. Cement particle release is not suitable for the application as they may cause adverse reactions such as embolism. The purpose of the present study was to investigate the amount of the particles released in relation to various aqueous solutions and different preparation methods. As a result of the work presented here, a method was found to reduce the particle release by delayed admixing of the aqueous phase to the partially polymerized PMMA/MMA mixture. This method leads to a reduction in particle release of more than 50%, e.g. reduced from 1.3 to 0.6g particles per 4ml of cement. Despite these improvements, particle release could not be reduced to a suitable level comparable to regular vertebroplasty cement. Therefore, the practicability of the initially promising invention of porous PMMA, in order to make regular PMMA cement more compliant with cancellous bone remains an unsolved issue.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Spinal Fractures and Fixation Techniques · Pelvic and Acetabular Injuries · Spine and Intervertebral Disc Pathology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Percutaneous transpedicular vertebroplasty with PMMA: operative technique and early results. A prospective study for the treatment of osteoporotic compression fractures10.1007/s005860000182 ↗
2. Mathis JM, Deramond H, Belkoff SM. Percutaneous Vertebroplasty, 1st ed. New York, Berlin: Heidelberg; Springer Verlag; 2002.10.1007/978-1-4757-3694-6_1 ↗
3. Mechanical properties of adult vertebral cancellous bone: correlation with collagen intermolecular cross-links10.1359/jbmr.2002.17.9.1621 ↗
4. Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty10.1093/rheumatology/39.12.1410 ↗
5. The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis10.1097/01.BRS.0000061987.71624.17 ↗
6. Poly(methyl methacrylate)-aqueous phase blends: in situ curing porous materials10.1002/jbm.820100419 ↗
7. Boger A, Bisig A, Bohner M, Heini P, Schneider E. Variation of the mechanical properties of PMMA to suit osteoporotic cancellous bone. J Biomater Sci Polymer Edn, 2008;19(9):1125–42.10.1163/156856208785540154 ↗
8. Tissue engineering scaffolds using superstructures10.1016/0142-9612(96)85753-X ↗
9. Properties of an injectable low modulus PMMA bone cement for osteoporotic bone
10. Porous acrylic cement10.1002/jbm.820110306 ↗
11. Spengler H, Hermansson H, Engqvist H. Evaluation of the cohesiveness of injectable Ca-aluminate based materials in water and simulated body fluid during curing. Presented at GRIBOI. Berne, Switzerland: 2006.
12. Cardiovascular changes after pulmonary embolism from injecting calcium phosphate cement
13. Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants10.1097/00003086-199203000-00010 ↗
14. Compositional changes of a dicalcium phosphate dihydrate cement after implantation in sheep10.1016/S0142-9612(03)00234-5 ↗
15. Wheeler KD, Schenk B, Boger A, Heini P. Clinical investigation of PMMA cement viscosity during vertebroplasty. Presented at the Orthopaedic Research Society. San Diego, USA: 2007.