Vibration Control of a Power Transmission Tower with Pounding Tuned Mass Damper under Multi-Component Seismic Excitations
Source abstract
Abstract
In this paper, the two-dimensional vibration controls of a power transmission tower with a pounding tuned mass damper (PTMD) under multi-component seismic excitations are analyzed. A three-dimensional finite element model of a practical power transmission tower is established in ABAQUS (Dassasult Simulia Company, Providence, RI, USA). The TMD (tuned mass damper) and PTMD are simulated by the finite element method. The response of the transmission tower with TMD and PTMD are analyzed, respectively. To achieve optimal design, the influence of the mass ratio, ground motion intensity, gap, and incident angle of seismic ground motion are investigated, respectively. The results show that the PTMD is very effective in reducing the vibration of the transmission tower in the longitudinal and transverse directions. The reduction ratio increases with the increase of the mass ratio. The ground motion intensity and gap have no obvious influence on the reduction ratio. However, the incident angle has a significant influence on the reduction ratio.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Vibration and Dynamic Analysis · Vibration Control and Rheological Fluids · Fluid Dynamics and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Civil Engineering, Shandong University, Jinan 250061, Shandong Province, China
Transportation Equipment and Ocean Engineering College, Dalian Maritime University, Dalian 116026, Liaoning Province, China
Funding
Key Research and Development Plan of Shandong Province
References (21)
Show source-provided references
1. Hall, F.J. (1995). Northridge Earthquake of January 17, 1994: Reconnaissance Report, Earthquake Engineering Research Institute.
2. Damages to life-line systems caused by Hyogoken Nanbu, Japan, earthquake and their recovery
3. Investigation and Preliminary Analysis of Damages on the Power Grid in the Wenchuan Earthquake of M8.0
4. Investigation and Analysis of Electric Equipment Damage in Sichuan Power Grid Caused by Wenchuan Earthquake
5. Analysis on seismic disaster damage cases and their causes of electric power equipment in 5.12 Wenchuan earthquake
6. Seismic damage investigation and analysis of electric power system in Lushan Ms 7.0 earthquake
7. Kilroe, N. (2000, January 8–12). Aerial method to mitigate vibration on transmission towers. Proceedings of the 2000 IEEE ESMO—2000 IEEE 9th International Conference on Transmission and Distribution Construction, Operation and Live-Line Maintenance Proceedings, Montreal, QC, Canada.
8. Dynamic behavior and stability of transmission line towers under wind forces10.1016/S0167-6105(03)00052-7 ↗
9. Cyclic loading test of friction-type reinforcing members upgrading wind-resistant performance of transmission towers10.1016/j.engstruct.2007.03.022 ↗
10. Control of wind-induced response of transmission tower-line system by using magnetorheological dampers10.1142/S0219455409003235 ↗
11. Simulation of galloping and wind-induced vibration control10.1260/0957-4565.41.10.15 ↗
12. Study on seismic control of power transmission tower-line coupled system under multicomponent excitations
13. A fundamental study on impact dampers10.1016/0890-6955(94)90009-4 ↗
14. A combined tuned absorber and pendulum impact damper under random excitation10.1006/jsvi.1997.1666 ↗
15. Free vibration analysis of a resilient impact damper10.1016/S0020-7403(03)00116-4 ↗
16. Seismic control of power transmission tower using pounding TMD10.1061/(ASCE)EM.1943-7889.0000576 ↗
17. Parametric study of pounding tuned mass damper for subsea jumpers10.1088/0964-1726/25/1/015028 ↗
18. Vibration control of a pipeline structure using pounding tuned mass damper10.1061/(ASCE)EM.1943-7889.0001078 ↗
19. Robustness study of the pounding tuned mass damper for vibration control of subsea jumpers10.1088/0964-1726/24/9/095001 ↗
20. Vibration control of a traffic signal pole using a pounding tuned mass damper with viscoelastic materials (II): Experimental verification10.1177/1077546313488407 ↗
21. (2010). GB 50011-2010, Code for Seismic Design of Buildings.