Personal Control of the Indoor Environment in Offices: Relations with Building Characteristics, Influence on Occupant Perception and Reported Symptoms Related to the Building—The Officair Project

Ioannis Sakellaris, Dikaia Saraga, Corinne Mandin, Yvonne de Kluizenaar, Serena Fossati, Andrea Spinazzè, Andrea Cattaneo, Tamas Szigeti, Victor Mihucz, Eduardo de Oliveira Fernandes, Krystallia Kalimeri, Paolo Carrer, John Bartzis

Applied Sciences· Volume 9· Issue 16

Abstract

Personal control over various indoor environment parameters, especially in the last decades, appear to have a significant role on occupants’ comfort, health and productivity. To reveal this complex relationship, 7441 occupants of 167 recently built or retrofitted office buildings in eight European countries participated in an online survey about personal/health/work data as well as physical/psycho-social information. The relationship between the types of control available over indoor environments and the perceived personal control of the occupants was examined, as well as the combined effect of the control parameters on the perceived comfort using multilevel statistical models. The results indicated that most of the occupants have no or low control on noise. Half of the occupants declared no or low control on ventilation and temperature conditions. Almost one-third of them remarked that they do not have satisfactory levels of control for lighting and shading from sun conditions. The presence of operable windows was shown to influence occupants’ control perception over temperature, ventilation, light and noise. General building characteristics, such as floor number and floor area, office type, etc., helped occupants associate freedom positively with control perception. Combined controlling parameters seem to have a strong relation with overall comfort, as well as with perception regarding amount of privacy, office layout and decoration satisfaction. The results also indicated that occupants with more personal control may have less building-related symptoms. Noise control parameter had the highest impact on the occupants’ overall comfort.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Noise Effects and Management · Building Energy and Comfort Optimization · Facilities and Workplace Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, University of Western Macedonia, Sialvera & Bakola Str., 50100 Kozani, Greece

Environmental Research Laboratory, INRASTES, National Center for Scientific Research “DEMOKRITOS”, Aghia Paraskevi Attikis, P.O. Box 60228, 15310 Athens, Greece

Université Paris Est, CSTB-Centre Scientifique et Technique du Bâtiment, 84 avenue Jean Jaurès, 77447 Marne-la-Vallée Cedex 2, France

The Netherlands Organization for Applied Scientific Research (TNO), P.O. Box 96800, 2509 JE The Hague, The Netherlands

ISGlobal, Institute for Global Health, 08036 Barcelona, Spain

Department of Science and High Technology, University of Insubria, Via Valleggio 11, 22100 Como, Italy

Cooperative Research Centre for Environmental Sciences, Eötvös Loránd University, Pázmány Péter sétány 1/A, H-1117 Budapest, Hungary

Institute of Science and Innovation in Mechanical Engineering and Industrial Management, Rua Dr. Roberto Frias s/n, 4200-465 Porto, Portugal

Department of Biomedical and Clinical Sciences-Hospital “L. Sacco”, University of Milan, via G.B. Grassi 74, 20157 Milano, Italy

Funding

FP7 Environment

References (51)

Show source-provided references
1. The Role of Environmental Control on Environmental Satisfaction, Communication, and Psychological Stress: Effects of Office Ergonomics Training10.1177/0013916503262543 ↗
2. Environmental Health Disparities: A Framework Integrating Psychosocial and Environmental Concepts10.1289/ehp.7074 ↗
3. Indoor air quality investigation of the school environment and estimated health risks: Two-season measurements in primary schools in Kozani, Greece10.1016/j.apr.2016.07.002 ↗
4. Effects of control over office workspace on perceptions of the work environment and work outcomes10.1016/j.jenvp.2005.08.001 ↗
5. Air quality and thermal comfort in office buildings: Results of a large indoor environmental quality survey
6. Occupant satisfaction in mixed-mode buildings10.1080/09613210902899785 ↗
7. Relating occupant perceived control and thermal comfort: Statistical analysis on the ASHRAE RP-884 database10.1080/10789669.2011.607882 ↗
8. Office worker response to an automated Venetian blind and electric lighting system: A pilot study10.1016/S0378-7788(98)00023-1 ↗
9. Can personal control over the physical environment ease distractions in office workplaces?10.1080/00140130903389019 ↗
10. The Impact of Personal Control over Office Workspace on Environmental Satisfaction and Performance
11. Study of indoor environmental quality and occupant overall comfort and productivity in LEED- and non-LEED–certified healthcare settings10.1177/1420326X16684007 ↗
12. Influences of perceived control on thermal comfort and energy use in buildings10.1016/j.enbuild.2017.10.044 ↗
13. Occupants’ Perceptions about Indoor Environment Comfort and Energy Related Values in Commercial and Residential Buildings10.1016/j.proenv.2016.04.055 ↗
14. Impact of indoor environmental quality on occupant well-being and comfort: A review of the literature10.1016/j.ijsbe.2016.03.006 ↗
15. Quantitative relationships between occupant satisfaction and satisfaction aspects of indoor environmental quality and building design10.1111/j.1600-0668.2011.00745.x ↗
16. Paciuk, M. (1989). The Role of Personal Control of the Environment in Thermal Comfort and Satisfaction at the Workplace, University of Wisconsin-Milwaukee.
17. Second-Level Post-Occupancy Evaluation Analysis10.1080/00994480.1990.10747961 ↗
18. Bordass, B., Bromley, K., and Leaman, A. (1993). User and Occupant Controls in Office Buildings, BRE.
19. Impact of psycho-social factors on perception of the indoor air environment studies in 12 office buildings10.1016/S0360-1323(98)00034-1 ↗
20. Health and Indoor Climate Complaints of 7043 office Workers in 61 Buildings in the Netherlands10.1111/j.1600-0668.1992.00001.x ↗
21. Central automatic control or distributed occupant control for better indoor environment quality in the future10.1016/j.buildenv.2009.03.011 ↗
22. Listening to the occupants: A Web-based indoor environmental quality survey10.1111/j.1600-0668.2004.00301.x ↗
23. Impact of available and perceived control on comfort and health in European offices10.1080/00038628.2012.744298 ↗
24. Personal control and environmental user satisfaction in office buildings: Results of case studies in the Netherlands10.1016/j.buildenv.2018.12.021 ↗
25. The underlying linkage between personal control and thermal comfort: Psychological or physical effects?10.1016/j.enbuild.2015.11.004 ↗
26. Thermal comfort and use of thermostats in Finnish homes and offices10.1016/j.buildenv.2008.09.002 ↗
27. Developing an Adaptive Model of Thermal Comfort and Preference
28. (2013). ASHRAE Standard 55 Thermal Environmental Conditions for Human Occupancy, ANSI/ASHRAE.
29. (2019, July 26). International Organization for Standardization ISO 7730:2005. Available online: http://www.iso.org/cms/render/live/en/sites/isoorg/contents/data/standard/03/91/39155.html.
30. Introduction to thermal comfort standards and to the proposed new version of EN ISO 773010.1016/S0378-7788(02)00004-X ↗
31. (2019, August 06). OFFICAIR Project. Available online: http://www.officair-project.eu/.
32. Ozone-initiated Terpene Reaction Products in Five European Offices: Replacement of a Floor Cleaning Agent10.1021/es504106j ↗
33. An integrated approach for the chemical characterization and oxidative potential assessment of indoor PM2.510.1016/j.microc.2014.10.006 ↗
34. Self-reported health and comfort in ‘modern’ office buildings: First results from the European OFFICAIR study10.1111/ina.12196 ↗
35. Office characteristics and dry eye complaints in European workers-The OFFICAIR study10.1016/j.buildenv.2016.03.013 ↗
36. Sakellaris, I., Saraga, D., Mandin, C., Roda, C., Fossati, S., de Kluizenaar, Y., Carrer, P., Dimitroulopoulou, S., Mihucz, V., and Szigeti, T. (2016). Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study. Int. J. Environ. Res. Public Health, 13.10.3390/ijerph13050444 ↗
37. Oxidative potential and chemical composition of PM2.5 in office buildings across Europe—The OFFICAIR study10.1016/j.envint.2016.04.015 ↗
38. VOCs and aldehydes source identification in European office buildings—The OFFICAIR study10.1016/j.buildenv.2017.01.009 ↗
39. Assessment of indoor air quality in office buildings across Europe—The OFFICAIR study10.1016/j.scitotenv.2016.10.238 ↗
40. Spatial and temporal variation of particulate matter characteristics within office buildings—The OFFICAIR study10.1016/j.scitotenv.2017.01.013 ↗
41. Questionnaire design for sick building syndrome: An empirical comparison of options10.1016/0160-4120(95)00104-2 ↗
42. Kruskal-Wallis test: BASIC computer program to perform nonparametric one-way analysis of variance and multiple comparisons on ranks of several independent samples10.1016/0169-2607(86)90081-7 ↗
43. Gelman, A., and Hill, J. (2007). Data Analysis Using Regression and Multilevel/Hierarchical Models, Cambridge University Press.10.32614/CRAN.package.arm ↗
44. Goldstein, H. (2011). Multilevel Statistical Models, John Wiley & Sons.10.1002/9780470973394 ↗
45. A guide to appropriate use of Correlation coefficient in medical research
46. (2013). IBM SPSS Statistics for Windows, IBM. Version 22.0.
47. Operable Windows, Personal Control, and Occupant Comfort
48. Thermal comfort: Use of controls in naturally ventilated buildings10.1016/S0378-7788(00)00087-6 ↗
49. Gou, Z., Zhang, J., and Shutter, L. (2018). The Role of Personal Control in Alleviating Negative Perceptions in the Open-Plan Workplace. Buildings, 8.10.3390/buildings8080110 ↗
50. User attitudes toward occupant controlled office lighting10.1191/1365782802lt048oa ↗
51. Perceived health and comfort in relation to energy use and building characteristics10.1080/09613210600822279 ↗