journal article·2020-11-10Open access

Daylighting Performance of Light Shelf Photovoltaics (LSPV) for Office Buildings in Hot Desert-Like Regions

Abdelhakim Mesloub, Aritra Ghosh

Applied Sciences· Volume 10· Issue 22

Abstract

Visual comfort and energy consumption for lighting in large office buildings is an area of ongoing research, specifically focusing on the development of a daylight control technique (light shelf) combined with solar energy. This study aims to investigate the optimum performance of light shelf photovoltaics (LSPV) to improve daylight distribution and maximize energy savings for the hot desert-like climate of Saudi Arabia. A radiance simulation analysis was conducted in four phases to evaluate: appropriate height, reflector, internal curved light shelf (LS) angle, and the integrated photovoltaic (PV) with various coverages (25%, 50%, 75%, and entirely external LS). The results revealed that the optimum is achieved at a height of 1.3 m, the addition of a 30 cm reflector on the top of a window with an internal LS curved angle of 10° with 100% coverage (LSPV1, LSPV2). Such an arrangement reduces the energy consumption by more than 85%, eliminates uncomfortable glare, and provides uniform daylight except for during the winter season. Hence, the optimization of the LSPV system is considered to be an effective solution for sustainable buildings.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Building Energy and Comfort Optimization · Impact of Light on Environment and Health · Urban Heat Island Mitigation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Architectural Engineering, Ha’il University, Ha’il 2440, Saudi Arabia

College of Engineering, Mathematics and Physical Sciences, Renewable Energy, University of Exeter, Penryn, Cornwall TR10 9FE, UK

References (35)

Show source-provided references
1. (2020, November 05). Saudi Vision 2030, Available online: https://vision2030.gov.sa/en/node/6.
2. Energy-saving potential of daylighting in the Atria of Colleges in Najran University, Saudi Arabia10.11113/ijbes.v7.n1.421 ↗
3. Assessment of solar radiation resources in Saudi Arabia10.1016/j.solener.2015.06.031 ↗
4. Efficiency, S.E. (2018). Saudi Energy Efficiency Program, Governmental and Commercial Sector.
5. Dynamic internal light shelf for tropical daylighting in high-rise office buildings10.1016/j.buildenv.2016.06.030 ↗
6. Experimental analysis of the performance of light shelves in different geometrical configurations through the scale model approach10.15627/jd.2020.4 ↗
7. Kontadakis, A., Tsangrassoulis, A., Doulos, L., and Zerefos, S. (2018). A review of light shelf designs for daylit environments. Sustainability, 10.10.3390/su10010071 ↗
8. Mesloub, A., Albaqawy, G.A., and Kandar, M.Z. (2020). The OPTIMUM performance of Building Integrated Photovoltaic (BIPV) windows under a semi-arid climate in algerian office buildings. Sustainability, 12.10.3390/su12041654 ↗
9. Daylight control and performance in office buildings using a novel ceramic louvre system10.1016/j.buildenv.2019.01.030 ↗
10. Horizontal light pipe transporter for deep plan high-rise office daylighting in tropical climate10.1016/j.buildenv.2020.106645 ↗
11. Maximizing the lightshelf performance by interaction between lightshelf geometries and a curved ceiling10.1016/j.enconman.2009.09.037 ↗
12. Chieli, G., and Nelli, L.C. (2019). Photovoltaic and thermal solar concentrator integrated into a dynamic shading device. Sustainable Building for a Cleaner Environment, Springer.10.1007/978-3-319-94595-8_28 ↗
13. Performance evaluation of a light shelf with a solar module based on the solar module attachment area10.1016/j.buildenv.2019.106161 ↗
14. Active control of daylighting features in buildings10.1111/j.1467-8667.2010.00692.x ↗
15. Evaluating daylight performance of light shelves combined with external blinds in south-facing classrooms in Athens, Greece10.1016/j.enbuild.2016.01.009 ↗
16. A preliminary study on the performance of an awning system with a built-in light shelf10.1016/j.buildenv.2018.01.016 ↗
17. Power performance of photovoltaic-integrated lightshelf systems10.1177/1420326X14525062 ↗
18. Analysis of the impacts of light shelves on the useful daylight illuminance in office buildings in Toronto10.1016/j.egypro.2015.11.310 ↗
19. Moazzeni, M.H., and Ghiabaklou, Z. (2016). Investigating the influence of light shelf geometry parameters on daylight performance and visual comfort, a case study of educational space in Tehran, Iran. Buildings, 6.10.3390/buildings6030026 ↗
20. Energy-saving performance of light shelves under the application of user-awareness technology and light-dimming control10.1016/j.scs.2018.10.005 ↗
21. Development and performance evaluation of light shelves using width-adjustable reflectors10.1155/2018/2028065 ↗
22. Optimization of daylight performance based on controllable light-shelf parameters using genetic algorithms in the tropical climate of malaysia10.15627/jd.2020.10 ↗
23. Lee, H., and Seo, J. (2020). Performance evaluation of external light shelves by applying a prism sheet. Energies, 13.10.3390/en13184618 ↗
24. International standard organization(ISO) (2002). Lighting of Indoor Work Places, ISO.
25. DiLaura, D.L. (2020, November 09). Illuminating Engineering Societythe Lighting HandbookTenth Edition Reference and Application. Available online: http://ndl.ethernet.edu.et/handle/123456789/23109.
26. JISZ9110 (2010). Recommended Levels of Illumination, Japanese Industrial Standards Committee.
27. De Normalisation, C.E. (2002). EN 12464-1: Light and Lighting-Lighting of Work Places, Part 1: Indoor Work Places, Comité Européen de Normalisation.
28. Dynamic daylight simulations: Impact of weather file’s choice10.1016/j.solener.2015.05.002 ↗
29. Remund, J., Müller, S., Kunz, S., Huguenin-Landl, B., Studer, C., Klauser, D., Schilter, C., and Lehnherr, R. (2013). Meteonorm global meteorological database. Hanbook I/II, Meteotest.
30. The benefits of light shelves over the daylight illuminance in office buildings in Toronto10.1177/1420326X16673413 ↗
31. Joarder, M., Rahman, A., Ahmed, Z.N., Price, A., and Mourshed, M. (2009). A Simulation Assessment of the Height of Light Shelves to Enhance Daylighting Quality in Tropical Office Buildings under Overcast Sky Conditions in Dhaka, Bangladesh, International Building Performance Simulation Association.
32. Hu, J., Du, J., and Place, W. (2011, January 8–13). The assessment of advanced daylighting systems in multi-story office buildings using a dynamic method. Proceedings of the World Renewable Energy Congress-Sweden, Linköping, Sweden.10.3384/ecp110571867 ↗
33. Daylight factor (overcast sky) versus daylight availability (clear sky) in computer-based daylighting simulations
34. Optimum glazing configurations for visual performance in algerian classrooms under mediterranean climate10.15627/jd.2019.2 ↗
35. Lee, H., Seo, J., and Choi, C.H. (2019). Preliminary study on the performance evaluation of a light shelf based on reflector curvature. Energies, 12.10.3390/en12224295 ↗