journal article·2009-07

Osteoconductivity of hydrophilic microstructured titanium implants with phosphate ion chemistry

Jin-Woo Park, Je-Hee Jang, Chong Soo Lee, Takao Hanawa

Acta Biomaterialia· Volume 5· Issue 6
Publisher page

Abstract

This study investigated the surface characteristics and bone response of titanium implants produced by hydrothermal treatment using H(3)PO(4), and compared them with those of implants produced by commercial surface treatment methods - machining, acid etching, grit blasting, grit blasting/acid etching or spark anodization. The surface characteristics were evaluated by scanning electron microscopy, thin-film X-ray diffractometry, X-ray photoelectron spectroscopy, contact angle measurement and stylus profilometry. The osteoconductivity of experimental implants was evaluated by removal torque testing and histomorphometric analysis after 6 weeks of implantation in rabbit tibiae. Hydrothermal treatment with H(3)PO(4) and subsequent heat treatment produced a crystalline phosphate ion-incorporated oxide (titanium oxide phosphate hydrate, Ti(2)O(PO(4))(2)(H(2)O)(2); TiP) surface approximately 5microm in thickness, which had needle-like surface microstructures and superior wettability compared with the control surfaces. Significant increases in removal torque forces and bone-to-implant contact values were observed for TiP implants compared with those of the control implants (p<0.001). After thorough cleaning of the implants removed during the removal torque testing, a considerable quantity of attached bone was observed on the surfaces of the TiP implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws
2. Applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: a prospective multicenter study on 558 fixtures
3. The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis10.1902/jop.1991.62.1.2 ↗
4. A multi-center study comparing dual acid-etched and machined-surfaced implants in various bone qualities10.1902/jop.2001.72.10.1384 ↗
5. Enhanced bone apposition to a chemically modified SLA titanium surface10.1177/154405910408300704 ↗
6. The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: early results from clinical trials on ITI SLA implants10.1034/j.1600-0501.2002.130204.x ↗
7. Implantation of hydrophilic and hydrophobic titanium discs in rat tibia: cellular reactions on the surfaces during the first 3 weeks in bone10.1016/j.biomaterials.2003.12.006 ↗
8. Effects of calcium ion incorporation on bone healing of Ti6Al4V alloy implants in rabbit tibiae10.1016/j.biomaterials.2007.04.007 ↗
9. Differentiation of preosteoblasts is affected by implant surface microtopographies10.1002/jbm.a.30016 ↗
10. High surface energy enhances cell response to titanium substrate microstructure10.1002/jbm.a.30320 ↗
11. The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant10.1016/S0142-9612(03)00261-8 ↗
12. The bone response of oxidized bioactive and non-bioactive titanium implants10.1016/j.biomaterials.2005.04.058 ↗
13. Effects of calcium ion incorporation on osteoblast gene expression in MC3T3-E1 cells cultured on microstructured titanium surfaces10.1002/jbm.a.31618 ↗
14. Effects of a novel calcium titanate coating on the osseointegration of blasted endosseous implants in rabbit tibiae10.1111/j.1600-0501.2006.01323.x ↗
15. Effect of phosphorus-ion implantation on the corrosion resistance and biocompatibility of titanium10.1016/S0142-9612(02)00020-0 ↗
16. Effect of dual ion implantation of calcium and phosphorus on the properties of titanium10.1016/j.biomaterials.2004.08.015 ↗
17. The role of surface functional groups in calcium phosphate nucleation on titanium foil: a self-assembled monolayer technique10.1016/S0142-9612(02)00050-9 ↗
18. Park JW. Method of fabricating implant with improved surface properties and implant fabricated by the same method. KR Patent No. 100775537, 2007.
19. A quantitative comparison of machined commercially pure titanium and titanium–aluminum–vanadium implants in rabbit bone
20. Synthesis and X-ray powder structures of three novel titanium phosphate compounds10.1006/jssc.1997.7470 ↗
21. Effects of topography and composition of titanium surface oxides on osteoblast responses10.1016/j.biomaterials.2003.11.011 ↗
22. Effects of implant microtopography on osteoblast cell attachment10.1097/01.ID.0000058309.77613.87 ↗
23. Bone cell attachment to dental implants of different surface characteristics
24. Bone–implant contact and bone quality: evaluation of expected and actual bone contact on machined and osseotite implant surfaces
25. Mechanisms of endosseous integration
26. Biological properties of acid etched titanium surface. Effect of sandblasting on bone anchorage10.1002/jbm.b.20003 ↗
27. Bone response to alteration of surface topography and surface composition of sandblasted and acid etched (SLA) implants10.1034/j.1600-0501.2002.130504.x ↗
28. Hydrogen absorption behavior of beta titanium alloy in acid fluoride solutions10.1016/j.biomaterials.2003.09.006 ↗
29. Hydrogen desorption from sand-blasted and acid-etched titanium surfaces after glow-discharge treatment10.1002/1097-4636(200101)54:1<20::AID-JBM3>3.0.CO;2-Z ↗
30. The stress corrosion cracking and hydrogen embrittlement of titanium in methanol–hydrochloric acid solutions10.1016/0010-938X(93)90102-M ↗
31. Wennerberg A, Albrektsson T, Lausmaa J. Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25- and 75-microns-sized particles of Al2O3. J Biomed Mater Res 1996;30:251–260.10.1002/(SICI)1097-4636(199602)30:2<251::AID-JBM16>3.0.CO;2-P ↗
32. A histomorphometric evaluation of screw-shaped implants each prepared with two surface roughnesses10.1034/j.1600-0501.1998.090102.x ↗
33. A torque removal study on the primary stability of orthodontic titanium screw mini-implants in the cortical bone of dog femurs10.1016/j.ijom.2008.04.007 ↗
34. Microdamage in cortical bone due to the overtightening of orthodontic microscrews10.1007/s00056-008-0742-5 ↗
35. Hydroxyapatite binds more serum proteins, purified integrins, and osteoblast precursor cells than titanium or steel10.1002/1097-4636(200111)57:2<258::AID-JBM1166>3.0.CO;2-R ↗
36. Formation of focal adhesions by osteoblasts adhering to different substrata10.1006/excr.1994.1257 ↗
37. Enhancing surface free energy and hydrophilicity thorough chemical modification of microstructured titanium implant surfaces10.1002/jbm.a.30518 ↗
38. Anode glow discharge plasma treatment of titanium plates facilitates adsorption of extracellular matrix proteins to the plates10.1177/154405910508400717 ↗
39. Glow discharge plasma treatment to titanium plates enhances adhesion of osteoblast-like cells to the plates through the integrin-mediated mechanism
40. Anode glow discharge plasma treatment enhances calcium phosphate adsorption onto titanium plates10.1177/154405910208101209 ↗
41. Surface modification and cell–materials interactions with anodized Ti10.1016/j.actbio.2006.12.003 ↗
42. From microroughness to resorbable bioactive coatings. Bio-implant interface
43. Qualitative and quantitative observations of bone tissue reactions to anodised implants10.1016/S0142-9612(01)00307-6 ↗
44. Calcium phosphate naturally formed on titanium in electrolyte solution10.1016/0142-9612(91)90028-9 ↗
45. Preparation of bioactive titanium metal via anodic oxidation treatment10.1016/S0142-9612(03)00626-4 ↗
46. Bonding of chemically treated titanium implants to bone10.1002/(SICI)1097-4636(199711)37:2<267::AID-JBM17>3.0.CO;2-B ↗
47. Influence of anodic oxidation on the bioactivity and corrosion resistance of phosphorus–ion implanted titanium10.1016/S0042-207X(02)00628-0 ↗
48. Characterization of titanium surfaces with calcium and phosphate and osteoblast adhesion10.1016/j.biomaterials.2003.10.044 ↗