journal article·2018-02-12Open access

Effective Biopotential Signal Acquisition: Comparison of Different Shielded Drive Technologies

Yanbing Jiang, Oluwarotimi Samuel, Xueyu Liu, Xin Wang, Paul Idowu, Peng Li, Fei Chen, Mingxing Zhu, Yanjuan Geng, Fengxia Wu, Shixiong Chen, Guanglin Li

Applied Sciences· Volume 8· Issue 2

Abstract

Biopotential signals are mainly characterized by low amplitude and thus often distorted by extraneous interferences, such as power line interference in the recording environment and movement artifacts during the acquisition process. With the presence of such large-amplitude interferences, subsequent processing and analysis of the acquired signals becomes quite a challenging task that has been reported by many previous studies. A number of software-based filtering techniques have been proposed, with most of them being able to minimize the interferences but at the expense of distorting the useful components of the target signal. Therefore, this study proposes a hardware-based method that utilizes a shielded drive circuit to eliminate extraneous interferences on biopotential signal recordings, while also preserving all useful components of the target signal. The performance of the proposed method was evaluated by comparing the results with conventional hardware and software filtering methods in three different biopotential signal recording experiments (electrocardiogram (ECG), electro-oculogram (EOG), and electromyography (EMG)) on an ADS1299EEG-FE platform. The results showed that the proposed method could effectively suppress power line interference as well as its harmonic components, and it could also significantly eliminate the influence of unwanted electrode lead jitter interference. Findings from this study suggest that the proposed method may provide potential insight into high quality acquisition of different biopotential signals to greatly ease subsequent processing in various biomedical applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Muscle activation and electromyography studies · EEG and Brain-Computer Interfaces · ECG Monitoring and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China

Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China

Institute of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing 400054, China

The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou 510630, China

Southern University of Science and Technology, Shenzhen 518055, China

Department of Anatomy, School of Medicine, Shandong University, Jinan 250100, China

Funding

Shenzhen High-level Overseas Talent Program · National Natural Science Foundation of China · the Shenzhen Basic Research Grant

References (47)

Show source-provided references
1. Pu, X., Wan, L., Sheng, Y., Chiang, P., Qin, Y., and Hong, Z. (2012, January 21–23). A Wireless 8-Channel ECG Biopotential Acquisition System for Dry Electrodes. Proceedings of the 2012 IEEE International Symposium on Radio-Frequency Integration Technology (RFIT), Singapore.10.1109/RFIT.2012.6401640 ↗
2. Burns, A., Doheny, E.P., Greene, B.R., Foran, T., Leahy, D., O’Donovan, K., and Mcgrath, M.J. (September, January 31). Shimmer: An Extensible Platform for Physiological Signal Capture. Proceedings of the 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, Buenos Aires, Argentina.10.1109/IEMBS.2010.5627535 ↗
3. Pradhan, A., Nayak, S.K., Pande, K., Ray, S.S., Pal, K., Champaty, B., Anis, A., and Tibarewala, D.N. (2016, January 16–18). Acquisition and Classification of Emg Using a Dual-Channel Emg Biopotential Amplifier for Controlling Assistive Devices. Proceedings of the 2016 IEEE Annual India Conference (INDICON), Bangalore, India.10.1109/INDICON.2016.7839015 ↗
4. Adli, Y.Y., Nakamura, T., and Kitaoka, K. (2000, January 1–4). Automatic Interference Controller Device for Eliminating the Power-Line Interference in Biopotential Signals. Proceedings of the 17th IEEE Instrumentation and Measurement Technology Conference, Baltimore, MD, USA.
5. Towards Efficient Decoding of Multiple Classes of Motor Imagery Limb Movements Based on Eeg Spectral and Time Domain Descriptors10.1007/s10916-017-0843-z ↗
6. Developments in ECG Acquisition, Preprocessing, Parameter Measurement, and Recording10.1109/51.664031 ↗
7. Resolving the Adverse Impact of Mobility on Myoelectric Pattern Recognition in Upper-Limb Multifunctional Prostheses10.1016/j.compbiomed.2017.09.013 ↗
8. Pattern Recognition of Electromyography Signals Based on Novel Time Domain Features for Amputees’ Limb Motion Classification
9. A Fully Automated Correction Method of Eog Artifacts in EEG Recordings10.1016/j.clinph.2006.09.003 ↗
10. Ferdi, Y. (2010, January 21–23). Improved Lowpass Differentiator for Physiological Signal Processing. Proceedings of the International Symposium on Communication Systems Networks and Digital Signal Processing, Newcastle upon Tyne, UK.10.1109/CSNDSP16145.2010.5580319 ↗
11. Removal of Power-Line Interference from the ECG: A Review of the Subtraction Procedure10.1186/1475-925X-4-50 ↗
12. The Research of Removing Baseline Wander for ECG
13. Filtering the Surface EMG Signal: Movement Artifact and Baseline Noise Contamination10.1016/j.jbiomech.2010.01.027 ↗
14. EMG and EOG Artifacts in Brain Computer Interface Systems: A Survey10.1016/j.clinph.2006.10.019 ↗
15. Computerized Processing of EEG-EOG-EMG Artifacts for Multi-Centric Studies in Eeg Oscillations and Event-Related Potentials10.1016/S0167-8760(02)00153-8 ↗
16. Magri, J., Grech, I., Casha, O., Gatt, E., and Micallef, J. (2016, January 11–14). Design of Cmos Front-End Circuitry for the Acquisition of Biopotential Signals. Proceedings of the 2016 IEEE International Conference on Electronics, Circuits and Systems, Monte Carlo, Monaco.10.1109/ICECS.2016.7841157 ↗
17. Removing Harmonic Power Line Interference from Biopotential Signals in Low Cost Acquisition Systems10.1016/j.compbiomed.2009.03.004 ↗
18. Mneimneh, M.A., Yaz, E.E., Johnson, M.T., and Povinelli, R.J. (2006, January 17–20). An Adaptive Kalman Filter for Removing Baseline Wandering in ECG Signals. Proceedings of the Computers in Cardiology, Valencia, Spain.
19. Chimene, M.F., and Pallas-Areny, R. (1999, January 24–26). A Comprehensive Model for Power-Line Interference in Biopotential Measurements. Proceedings of the 16th IEEE Instrumentation and Measurement Technology Conference, Venice, Italy.
20. Zhang, J., Wang, L., Yu, L., Yang, Y., Zhang, Y., and Li, B. (2009, January 3–6). A Low-Offset Analogue Front-End IC for Multi-Channel Physiological Signal Acquisition. Proceedings of the 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Minneapolis, MN, USA.
21. A Transconductance Driven-Right-Leg Circuit10.1109/10.804574 ↗
22. Power Line Interference Removal for High-Quality Continuous Biosignal Monitoring with Low-Power Wearable Devices10.1109/JSEN.2016.2536363 ↗
23. A Robust Adaptive Power Line Interference Canceler VLSI Architecture and Asic for Multichannel Biopotential Recording Applications
24. The Stability Analysis of a Biopotential Measurement System Equipped with Driven-Right-Leg and Shield-Driver Circuits10.1109/TIM.2013.2293811 ↗
25. Sudirman, R., Zakaria, N.A., Jamaluddin, M.N., Mohamed, M.R., and Khalid, K.N. (2009, January 25–29). Study of Electromagnetic Interference to ECG Using Faraday Shield. Proceedings of the Third Asia International Conference on Modelling & Simulation, Bali, Indonesia.10.1109/AMS.2009.58 ↗
26. Thin and Flexible Active Electrodes with Shield for Capacitive Electrocardiogram Measurement10.1007/s11517-010-0597-y ↗
27. Sullivan, T.J., Deiss, S.R., and Cauwenberghs, G. (2007, January 27–30). A Low-Noise, Non-Contact Eeg/Ecg Sensor. Proceedings of the Biomedical Circuits and Systems Conference, Montreal, QC, Canada.10.1109/BIOCAS.2007.4463332 ↗
28. Power Line Interference Rejection from Surface Electromyography Signal Using an Adaptive Algorithm10.1016/j.rbmret.2007.09.002 ↗
29. Jayant, H.K., Rana, K.P.S., Kumar, V., Nair, S.S., and Mishra, P. (2015, January 24–26). Efficient Iir Notch Filter Design Using Minimax Optimization for 50 Hz Noise Suppression in ECG. Proceedings of the 2015 International Conference on Signal Processing, Computing and Control (ISPCC), Waknaghat, India.10.1109/ISPCC.2015.7375043 ↗
30. Design of Digital Trap Filter for Reducing Power Line Interference in Semg
31. Two-Electrode Biopotential Measurements: Power Line Interference Analysis10.1109/TBME.2005.851488 ↗
32. A Method for Reduction of Power Line Interference in the ECG10.1016/j.medengphy.2004.08.014 ↗
33. Power-Line Interference Removal from ECG in Case of Power-Line Frequency Variations
34. A Comparison of Adaptive and Nonadaptive Filters for Reduction of Power Line Interference in the ECG10.1109/10.477707 ↗
35. Powerline Interference Reduction in ECG Using Combination of Ma Method and Iir Notch
36. A Novel Application of the S-Transform in Removing Powerline Interference from Biomedical Signals10.1088/0967-3334/30/1/002 ↗
37. Avendano-Valencia, L.D., Avendano, L.E., Ferrero, J.M., and Castellanos-Dominguez, G. (2007). Improvement of an Extended Kalman Filter Power Line Interference Suppressor for ECG Signals. 2007 Computers in Cardiology, IEEE.10.1109/CIC.2007.4745545 ↗
38. Reducing Power Line Interference in Digitised Electromyogram Recordings by Spectrum Interpolation10.1007/BF02350994 ↗
39. A Nonlinear Adaptive Method of Elimination of Power Line Interference in ECG Signals10.1109/TBME.2002.1001968 ↗
40. Weiting, Y., and Runjing, Z. (2007, January 16–18). An Improved Self-Adaptive Filter Based on Lms Algorithm for Filtering 50 Hz Interference in ECG Signals. Proceedings of the 2007 8th International Conference on Electronic Measurement and Instruments, Xi’an, China.10.1109/ICEMI.2007.4351057 ↗
41. A Fast, Robust Algorithm for Power Line Interference Cancellation in Neural Recording10.1088/1741-2560/11/2/026017 ↗
42. Isaksen, J., Leber, R., Schmid, R., Schmid, H.J., Generali, G., and Abächerli, R. (2016, January 20–25). The First-Order High-Pass Filter Influences the Automatic Measurements of the Electrocardiogram. Proceedings of the 2016 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Shanghai, China.10.1109/ICASSP.2016.7471782 ↗
43. Acharya, D., Rani, A., and Agarwal, S. (2015, January 2–4). EEG Data Acquisition Circuit System Based on ADS1299EEG-FE. Proceedings of the 2015 4th International Conference on Reliability, Infocom Technologies and Optimization (ICRITO), Noida, India.10.1109/ICRITO.2015.7359346 ↗
44. Arduino: A Low-Cost Multipurpose Lab Equipment10.3758/s13428-011-0163-z ↗
45. Stability and Accuracy of Active Shielding for Grounded Capacitive Sensors10.1088/0957-0233/17/11/004 ↗
46. Resistance to Ohm’s Law10.1119/1.1969620 ↗
47. Capacitive Driven-Right-Leg Circuit Design10.1504/IJBET.2015.068051 ↗