journal article·2020-02-21Open access

Classification of Photoplethysmographic Signal Quality with Fuzzy Neural Network for Improvement of Stroke Volume Measurement

Shing-Hong Liu, Jia-Jung Wang, Wenxi Chen, Kuo-Li Pan, Chun-Hung Su

Applied Sciences· Volume 10· Issue 4

Abstract

Photoplethysmography (PPG) has been extensively employed to acquire some physiological parameters such as heart rate, oxygen saturation, and blood pressure. However, PPG signals are frequently corrupted by motion artifacts and baseline wandering, especially for the reflective PPG sensor. Several different algorithms have been studied for determining the signal quality of PPG by the characteristic parameters of its waveform and the rule-based methods. The levels of signal quality usually were defined by the manual operations. Thus, whether the good PPG waveforms are enough to increase the accuracy of the measurement is still a subjective issue. The aim of this study is to use a fuzzy neural network to determine the signal quality indexes (SQI) of PPG pulses measured by the impedance cardiography. To test the algorithm performance, the beat-to-beat stroke volumes (SV) were measured with our device and the medis® CS 2000, synchronously. A total of 1466 pulses from 10 subjects were used to validate our algorithm in which the SQIs of 1007 pulses were high, those of 71 pulses were in the middle, and those of 388 pulses were low. The total error of SV measurement was −18 ± 22.0 mL. The performances of the classification were that the sensitivity and specificity for the 1007 pulses with the high SQIs were 0.81 and 0.90, and the error of SV measurement was 6.4 ± 12.8 mL. The sensitivity and specificity for the 388 pulses with the low SQIs were 0.84 and 0.93, while the error of SV measurement was 30.4 ± 3.6 mL. The results show that the proposed algorithm could be helpful in choosing good-quality PPG pulses to increase the accuracy of SV measurement in the impedance plethysmography.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy · Heart Rate Variability and Autonomic Control

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Computer Science and Information Engineering, Chaoyang University of Technology, Taichung City 41349, Taiwan

Department of Biomedical Engineering, I-Shou University, Kaohsiung City 82445, Taiwan

Biomedical Information Engineering Laboratory, The University of Aizu, Aizu-Wakamatsu City, Fukushima 965-8580, Japan

Division of Cardiology, Chiayi Chang Gung Memorial Hospital, Chiayi City 61363, Taiwan

Department of Traditional Chinese Medicine, College of Medicine, Chang Gung University, Taoyuan City 33305, Taiwan

Institute of Medicine, School of Medicine, Chung-Shan Medical University, Taichung 402, Taiwan

Department of Internal Medicine, Chung-Shan Medical University Hospital, Taichung 402, Taiwan

Funding

Ministry of Science and Technology in Taiwan

References (22)

Show source-provided references
1. Wearable sensors for remote health monitoring10.3390/s17010130 ↗
2. Assessment of pulse transit time to indicate cardiovascular changes during obstetric spinal anesthesia10.1093/bja/aei266 ↗
3. Photoplethysmography: Beyond the calculation of arterial oxygen saturation and heart rate10.1213/01.ane.0000269512.82836.c9 ↗
4. Liu, S.-H., Wang, J.-J., Su, C.-H., and Cheng, D.-C. (2018). Improvement of left ventricular ejection time measurement in the impedance cardiography combined with the reflection photoplethysmography. Sensors, 18.10.3390/s18093036 ↗
5. Onboard tagging for real-time quality assessment of photoplethysmograms acquired by a wireless reflectance pulse oximeter10.1109/TBCAS.2011.2157822 ↗
6. Motion artifact reduction in photoplethysmography using independent component analysis10.1109/TBME.2005.869784 ↗
7. Arterial waveforms measured at the wrist as indicators of diabetic endothelial dysfunction in the elderly10.1109/TIM.2011.2159416 ↗
8. Comparison of wavelet transformation and adaptive filtering in restoring artefact-induced time-related measurement10.1016/j.bspc.2006.01.001 ↗
9. Adaptive reduction of motion artifact from photoplethysmographic recordings using a variable step-size LMS filter10.1109/ICSENS.2002.1037314 ↗
10. Photoplethysmograph signal reconstruction based on a novel hybrid motion artifact detection–reduction approach part I: Motion and noise artifact detection10.1007/s10439-014-1080-y ↗
11. Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes10.1088/0967-3334/21/3/303 ↗
12. Photoplethysmography and its application in clinical physiological measurement10.1088/0967-3334/28/3/R01 ↗
13. Photoplethysmograph signal reconstruction based on a novel motion artifact detection-reduction approach part II: Motion and noise artifact removal10.1007/s10439-014-1080-y ↗
14. Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation10.1088/0967-3334/33/10/1617 ↗
15. Heart rate extraction from photoplethysmogram on fuzzy Logic discriminator10.1016/j.engappai.2010.02.008 ↗
16. An algorithm for real-time pulse waveform segmentation and artifact detection in photoplethysmograms10.1109/JBHI.2016.2518202 ↗
17. Development and evaluation of an impedance cardiograph system
18. A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale10.1097/00003246-198610000-00017 ↗
19. An on-line self-constructing neural fuzzy inference network and its application10.1109/91.660805 ↗
20. Arrhythmia identification with two-lead electrocardiograms using artificial neural networks and support vector machines for a portable ECG monitor system10.3390/s130100813 ↗
21. Kebede, T.M., Djaneye-Boundjou, O., Narayanan, B.N., Ralescu, A., and Kapp, D. (2017). Classification of malware programs using autoencoders based deep learning architecture and its application to the Microsoft malware classification challenge (big 2015) dataset. Proc. IEEE National Aerosp. Electr. Conf., 70–75.10.1109/NAECON.2017.8268747 ↗
22. Optimized feature selection-based clustering approach for computer-aided detection of lung nodules in different modalities10.1007/s10044-017-0653-4 ↗