Demonstration of Subretinal Injection Using Common-Path Swept Source OCT Guided Microinjector
Source abstract
Abstract
In this paper, we present the development of a handheld common-path swept source optical coherence tomography (CP-SSOCT) guided microinjector system and demonstrated its utility by precisely injecting fluorescein dye in the subretinal layer of ex vivo bovine eyes. The system enables precise subretinal injection with micron-level injection depth control. This was achieved by using a high-resolution CP-SSOCT distal sensor and signal processing using a graphics-processing unit (GPU), which made a real-time smart motion control algorithm possible. The microinjector performance was first evaluated using a gelatin phantom in terms of its ability for dynamic depth targeting and injection depth. This is followed by using an ex vivo bovine eye model to perform multiple consecutive subretinal injections of fluorescein dye. The results validated the OCT guided injector’s ability to precisely guide and lock in the needle tip to the target depth during injection. The ex vivo evaluation tests demonstrate that an OCT-guided injector can consistently guide the injecting needle to the desired depth and is able to maintain the position with 9.38 μm average root mean square error during the injections.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Retinal and Macular Surgery · Optical Coherence Tomography Applications · Retinal Diseases and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
Funding
National Institutes of Health
References (29)
Show source-provided references
1. A comprehensive review of retinal gene therapy10.1038/mt.2012.280 ↗
2. Human retinal gene therapy for Leber congenital amaurosis shows advancing retinal degeneration despite enduring visual improvement
3. Biological gene delivery vehicles: Beyond viral vectors10.1038/mt.2009.41 ↗
4. Singh, S.P.N., and Riviere, C.N. (2002, January 21). Physiological tremor amplitude during retinal microsurgery. Proceedings of the IEEE 28th Annual Northeast Bioengineering Conference, Philadelphia, PA, USA.10.1109/NEBC.2002.999520 ↗
5. Wang, W., Liu, X., Gelinas, D., Ciruna, B., and Sun, Y. (2007). A fully automated robotic system for microinjection of zebrafish embryos. PLoS ONE, 2.10.1371/journal.pone.0000862 ↗
6. Cooperative robot assistance for retinal microsurgery
7. Minimally invasive epicardial injections using a novel semiautonomous robotic device
8. Becker, B.C., Yang, S., MacLachlan, R.A., and Riviere, C.N. (2012, January 24–27). Towards vision-based control of a handheld micromanipulator for retinal cannulation in an eyeball phantom. Proceedings of the 4th IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), Rome, Italy.10.1109/BioRob.2012.6290813 ↗
9. Force-sensing microneedle for assisted retinal vein cannulation
10. Integration of a spectral domain optical coherence tomography system into a surgical microscope for intraoperative imaging10.1167/iovs.10-6720 ↗
11. Unprocessed real-time imaging of vitreoretinal surgical maneuvers using a microscope-integrated spectral-domain optical coherence tomography system10.1007/s00417-012-2052-2 ↗
12. Preclinical evaluation and intraoperative human retinal imaging with a highresolution microscope-integrated spectral domain optical coherence tomography device10.1097/IAE.0b013e3182831293 ↗
13. Miniature real-time intraoperative forward-imaging optical coherence tomography probe10.1364/BOE.4.001342 ↗
14. Evaluation of microsurgical tasks with OCT-guided and/or robot-assisted ophthalmic forceps10.1364/BOE.6.000457 ↗
15. Common-path interferometer for frequency-domain optical coherence tomography10.1364/AO.42.006953 ↗
16. All-Fiber Common-Path Optical Coherence Tomography: Sensitivity Optimization and System Analysis10.1109/JSTQE.2005.857380 ↗
17. Graphics processing unit accelerated non-uniform fast Fourier transform for ultrahigh-speed, real-time Fourier-domain OCT10.1364/OE.18.023472 ↗
18. A surface topology and motion compensation system for microsurgery guidance and intervention based on common-path optical coherence tomography10.1109/TBME.2009.2024077 ↗
19. Common-path low-coherence interferometry fiber-optic sensor guided microincision10.1117/1.3622492 ↗
20. Motion compensated fiber-optic confocal microscope based on a common-path optical coherence tomography distance sensor10.1117/1.3610980 ↗
21. Motion-compensated hand-held common-path Fourier-domain optical coherence tomography probe for image-guided intervention10.1364/BOE.3.003105 ↗
22. Active tremor cancellation by a “smart” handheld vitreoretinal microsurgical tool using swept source optical coherence tomography10.1364/OE.20.023414 ↗
23. Fiber-optic OCT sensor guided “SMART” micro-forceps for microsurgery10.1364/BOE.4.001045 ↗
24. Accurate real-time depth control for CP-SSOCT distal sensor based handheld microsurgery tools10.1364/BOE.6.001942 ↗
25. Mahvash, M., and Dupont, P.E. (2009, January 12–17). Fast needle insertion to minimize tissue deformation and damage. Proceedings of the IEEE International Conference on Robotics and Automation, Kobe, Japan.10.1109/ROBOT.2009.5152617 ↗
26. Mecahnics of dynamic needle insertion into a biological material10.1109/TBME.2009.2036856 ↗
27. The interpretation of optical coherence tomography images of the retina
28. Thickness profiles of reintal layers by optical coherence tomography image segmentation10.1016/j.ajo.2008.06.010 ↗
29. Automated detection of retinal layer structures on optical coherence tomography images10.1364/OPEX.13.010200 ↗