journal article·2019-07-06Open access

Self-Gated Respiratory Motion Rejection for Optoacoustic Tomography

Avihai Ron, Neda Davoudi, Xosé Luís Deán-Ben, Daniel Razansky

Applied Sciences· Volume 9· Issue 13

Abstract

Respiratory motion in living organisms is known to result in image blurring and loss of resolution, chiefly due to the lengthy acquisition times of the corresponding image acquisition methods. Optoacoustic tomography can effectively eliminate in vivo motion artifacts due to its inherent capacity for collecting image data from the entire imaged region following a single nanoseconds-duration laser pulse. However, multi-frame image analysis is often essential in applications relying on spectroscopic data acquisition or for scanning-based systems. Thereby, efficient methods to correct for image distortions due to motion are imperative. Herein, we demonstrate that efficient motion rejection in optoacoustic tomography can readily be accomplished by frame clustering during image acquisition, thus averting excessive data acquisition and post-processing. The algorithm’s efficiency for two- and three-dimensional imaging was validated with experimental whole-body mouse data acquired by spiral volumetric optoacoustic tomography (SVOT) and full-ring cross-sectional imaging scanners.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photoacoustic and Ultrasonic Imaging · Optical Imaging and Spectroscopy Techniques · Optical Coherence Tomography Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute for Biological and Medical Imaging, Helmholtz Center Munich, 85764 Neuherberg, Germany

Faculty of Medicine, Technical University of Munich, 81765 Munich, Germany

Institute for Biomedical Engineering and Department of Information Technology and Electrical Engineering, ETH Zurich, 8093 Zurich, Switzerland

Department of Informatics, Technical University of Munich, 85748 Garching, Germany

Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, 8057 Zurich, Switzerland

References (41)

Show source-provided references
1. Effect of respiratory gating on quantifying PET images of lung cancer
2. Effects of respiration-averaged computed tomography on positron emission tomography/computed tomography quantification and its potential impact on gross tumor volume delineation10.1016/j.ijrobp.2008.02.064 ↗
3. II The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging10.1088/0031-9155/54/24/007 ↗
4. Free-breathing cardiac MR imaging: Study of implications of respiratory motion—Initial results10.1148/radiol.2203010132 ↗
5. Comparison between prospective and retrospective triggering for mouse cardiac MRI10.1002/nbm.1110 ↗
6. Motion artifacts in MRI: A complex problem with many partial solutions10.1002/jmri.24850 ↗
7. PET/CT imaging artifacts
8. Nehmeh, S.A., and Erdi, Y.E. (2008). Respiratory Motion in Positron Emission Tomography/Computed Tomography: A Review, Elsevier.10.1053/j.semnuclmed.2008.01.002 ↗
9. Prospective motion correction in brain imaging: A review10.1002/mrm.24314 ↗
10. Respiratory motion models: A review10.1016/j.media.2012.09.005 ↗
11. Advanced optoacoustic methods for multiscale imaging of in vivo dynamics10.1039/C6CS00765A ↗
12. Characterization of Cardiac Dynamics in an Acute Myocardial Infarction Model by Four-Dimensional Optoacoustic and Magnetic Resonance Imaging10.7150/thno.20616 ↗
13. Rapid volumetric optoacoustic imaging of neural dynamics across the mouse brain10.1038/s41551-019-0372-9 ↗
14. Ron, A., and Deán-Ben, X.L. (2019). Volumetric optoacoustic imaging unveils high-resolution patterns of acute and cyclic hypoxia in a murine model of breast cancer. Cancer Res.10.1158/0008-5472.CAN-18-3769 ↗
15. Optoacoustic imaging at kilohertz volumetric frame rates10.1364/OPTICA.5.000857 ↗
16. Performance of a multispectral optoacoustic tomography (MSOT) system equipped with 2D vs. 3D handheld probes for potential clinical translation10.1016/j.pacs.2015.12.001 ↗
17. Optoacoustic micro-tomography at 100 volumes per second10.1038/s41598-017-06554-9 ↗
18. Ron, A., and Deán-Ben, X.L. (2018). Characterization of Brown Adipose Tissue in a Diabetic Mouse Model with Spiral Volumetric Optoacoustic Tomography. Mol. Imaging Biol.10.1007/s11307-018-1291-y ↗
19. Advances in real-time multispectral optoacoustic imaging and its applications10.1038/nphoton.2015.29 ↗
20. Light fluence normalization in turbid tissues via temporally unmixed multispectral optoacoustic tomography10.1364/OL.40.004691 ↗
21. Multiscale photoacoustic tomography using reversibly switchable bacterial phytochrome as a near-infrared photochromic probe10.1038/nmeth.3656 ↗
22. Video-rate functional photoacoustic microscopy at depths10.1117/1.JBO.17.10.106007 ↗
23. Motion clustering for deblurring multispectral optoacoustic tomography images of the mouse heart10.1117/1.JBO.17.1.016009 ↗
24. Retrospective respiration-gated whole-body photoacoustic computed tomography of mice10.1117/1.JBO.19.1.016003 ↗
25. Correlation between volumetric oxygenation responses and electrophysiology identifies deep thalamocortical activity during epileptic seizures10.1117/1.NPh.4.1.011007 ↗
26. Visualization of tumor-related blood vessels in human breast by photoacoustic imaging system with a hemispherical detector array10.1038/srep41970 ↗
27. Motion correction in optoacoustic mesoscopy10.1038/s41598-017-11277-y ↗
28. Motion estimation and correction in photoacoustic tomographic reconstruction10.1137/16M1082901 ↗
29. Functional optoacoustic imaging of moving objects using microsecond-delay acquisition of multispectral three-dimensional tomographic data10.1038/srep05878 ↗
30. Photoacoustic pump-probe tomography of fluorophores in vivo using interleaved image acquisition for motion suppression10.1038/srep40496 ↗
31. In vivo whole-body optoacoustic scanner with real-time volumetric imaging capacity10.1364/OPTICA.3.001153 ↗
32. Spiral volumetric optoacoustic tomography visualizes multi-scale dynamics in mice
33. Transmission–reflection optoacoustic ultrasound (TROPUS) computed tomography of small animals10.1038/s41377-019-0130-5 ↗
34. Universal back-projection algorithm for photoacoustic computed tomography10.1103/PhysRevE.71.016706 ↗
35. Ozbek, A., and Deán-Ben, X. (2013). Realtime Parallel Back-Projection Algorithm for Three-Dimensional Optoacoustic Imaging Devices, Optical Society of America.10.1117/12.2033376 ↗
36. Accounting for speed of sound variations in volumetric hand-held optoacoustic imaging10.1007/s12200-017-0739-z ↗
37. A universal image quality index10.1109/97.995823 ↗
38. Mice anesthesia, analgesia, and care, Part II: Anesthetic considerations in preclinical imaging studies10.1093/ilar.53.1.70 ↗
39. Cine-MRI assessment of cardiac function in mice anesthetized with ketamine/xylazine and isoflurane10.1007/s10334-004-0086-0 ↗
40. Multi-Spectral Optoacoustic Tomography (MSOT) of human breast cancer10.1158/1078-0432.CCR-16-3200 ↗
41. Non-invasive Measurement of Brown Fat Metabolism Based on Optoacoustic Imaging of Hemoglobin Gradients10.1016/j.cmet.2018.02.002 ↗