journal article·2020-09-28Open access

Investigation on the Formation Mechanism of Crack Indications and the Influences of Related Parameters in Magnetic Particle Inspection

Long Li, Yun Yang, Xiang Cai, Yihua Kang

Applied Sciences· Volume 10· Issue 19

Abstract

The recent rapid development of industrial cameras and machine learning has brought new vitality to the very traditional flaw detection method, namely, magnetic particle inspection (MPI). To fully develop automatic fluorescent MPI technology, two main issues need to be solved urgently—the lack of theoretical analysis on the formation of the crack indications, and quantitative characterization methods to determine the crack indications. Here, we carry out a theoretical analysis and an experimental approach to address these issues. Theoretical models of the acting force of the leakage magnetic field were established. Subsequently, the impacts of different magnetic field strengths (1000–9000 A/m) and magnetic particle concentrations (0.5–30 mL/L) on the adsorption critical distance were analyzed. The models were solved by numerical calculations in MATLAB. In addition, a single variable control experiment was conducted to study the effects of crack images. In order to determine the quality of the crack image, three characteristic parameters were investigated, such as indication gray scale, background gray scale, and contrast ratio, were provided. The theoretical magnetic particle concentration range provided a guidance value for automated fluorescent MPI. Experimental results revealed that the optimal magnetic particle concentration was 3–4 mL/L, and, under this condition, the contrast between the crack indications and the background of crack images was obvious.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Destructive Testing Techniques · Characterization and Applications of Magnetic Nanoparticles · Surface Roughness and Optical Measurements

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Key Lab of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China

College of Mechanical Engineering, Donghua University, Shanghai 201620, China

Funding

National Natural Science Foundation of China · Fundamental Research Funds for the Central Universities

References (30)

Show source-provided references
1. Application of Magnetic Particle Inspection in Boiler Inspection
2. Application of structural integrity assessment procedure on an axle pin of a wind turbine10.1111/ffe.12654 ↗
3. Crack detection algorithm for fluorescent magnetic particle inspection based on shape and texture features
4. Automated Magnetic Field Evaluation for Magnetic Particle Inspection by Impulse10.1007/s10921-019-0615-4 ↗
5. Automated magnetic particle testing
6. Measurement of magnetic particle amount and evaluation magnetic flux leakage density for quantitative evaluation in magnetic particle testing
7. Defect detection of magnetic particle indication image based on fractal dimension
8. Neural network-based inverse analysis for defect identification with laser ultrasonics10.1080/09349840109409688 ↗
9. Nishimine, T., Tsuyama, O., Tanaka, T., and Fujiwara, H. (1995). Automatic magnetic particle testing system for square billets. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting, Proceedings of the IAS’95, Orlando, FL, USA, 8–12 October 1995, IEEE.10.1109/IAS.1995.530493 ↗
10. Fully automatic magnetic-particle inspection system for square billets10.1016/S1474-6670(17)48210-3 ↗
11. Development of Automatic Fluorescent Magnetic Particle Testing of Square Steel Billets by Image Processing Technology
12. Three-dimensional real-timein vivomagnetic particle imaging10.1088/0031-9155/54/5/L01 ↗
13. Magnetization response spectroscopy of superparamagnetic nanoparticles for magnetic particle imaging10.1088/0022-3727/42/20/205007 ↗
14. Evaluation of a separate-receive coil by magnetic particle imaging of a solid phantom10.1016/j.jmmm.2018.09.114 ↗
15. Pulsed Excitation in Magnetic Particle Imaging10.1109/TMI.2019.2898202 ↗
16. Model-based reconstruction for magnetic particle imaging10.1109/TMI.2009.2021612 ↗
17. Non-destructive testing—Current capabilities and future directions
18. Liu, B., Liu, Z., Luo, N., He, L., and Ren, J. (2020). Research on Features of Pipeline Crack Signal Based on Weak Magnetic Method. Sensors, 20.10.3390/s20030810 ↗
19. Role of non-destructive evaluation in time-dependent reliability analysis10.1016/S0167-4730(98)00021-6 ↗
20. Theoretical analyses of MFL signal affected by discontinuity orientation and sensor-scanning direction
21. Yan, M., and Peng, X. (2006). Fundamentals of Magnetism and Magnetic Materials, Zhejiang University Press.
22. Progresses and Applications of Basset Force
23. Applications of non-destructive testing techniques for post-process control of additively manufactured parts10.1080/17452759.2017.1357319 ↗
24. A review of non-destructive testing methods of composite materials10.1016/j.prostr.2016.02.008 ↗
25. Evaluation of PEG-coated iron oxide nanoparticles as blood pool tracers for preclinical magnetic particle imaging10.1039/C6NR08468K ↗
26. Starmans, L.W.E., Moonen, R.P.M., Aussems-Custers, E., Daemen, M.J.A.P., and Strijkers, G.J. (2015). Evaluation of iron oxide nanoparticle micelles for magnetic particle imaging (MPI) of thrombosis. PLoS ONE, 10.10.1371/journal.pone.0119257 ↗
27. Microwave and millimeter wave nondestructive testing and evaluation-Overview and recent advances10.1109/MIM.2007.364985 ↗
28. Magnetic Resonance Imaging Evaluation of Remodeling by Cardiac Elastomeric Tissue Scaffold Biomaterials in a Rat Model of Myocardial Infarction10.1089/ten.tea.2010.0213 ↗
29. Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging10.1118/1.3554646 ↗
30. Determination of the magnetic particle distribution in tumour tissue by means of x-ray tomography10.1088/0953-8984/18/38/S25 ↗