Development of Robot-Assisted Untact Swab Sampling System for Upper Respiratory Disease
Source abstract
Abstract
We propose a new telerobotic system for untact swab sampling to prevent the infection of medical staff during upper respiratory sample collection. The system consists of a slave robot and two master devices. The slave robot is designed to move a swab in 6 degrees of freedom within the facial area and to insert and remove the swab under remote control by an operator at the master site based on magnified imaging of the patient’s facial area. The insertion and removal of the swab into and from the nostril are implemented by means of a swab insertion unit; as the counterpart to this unit, the master system also includes a swab insertion device to control the swab insertion unit remotely. A force sensor installed on the swab holder enables monitoring of the force generated when the swab touches the target. In experiments, a virtual specimen was installed on the posterior nasopharynx wall of a life-size head phantom model. The nasopharyngeal swab samplings of the phantom model were successfully performed thanks to the force monitoring capability of the proposed telerobotic system, showing that this system is suitable for remote upper respiratory sample collection.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Soft Robotics and Applications · COVID-19 diagnosis using AI · Dental Research and COVID-19
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Medical Assistant Robot Lab., Korea Institute of Machinery and Materials, Daegu 42994, Korea
Dept. of Neurology, Dongguk University Ilsan Hospital, Goyang 10326, Korea
Funding
National Research Council of Science & Technology · Korea Institute of Machinery and Materials
References (23)
Show source-provided references
1. A review of medical robotics for minimally invasive soft tissue surgery10.1243/09544119JEIM591 ↗
2. 30 Years of Robotic Surgery10.1007/s00268-016-3543-9 ↗
3. Review of emerging surgical robotic technology10.1007/s00464-018-6079-2 ↗
4. Xiang, Y., Shen, H., Xie, L., and Wang, H. (2019, January 14–18). Master-Slave Guidewire and Catheter Robotic System for Cardiovascular Intervention. Proceedings of the 28th IEEE International Conference on Robot and Human Interactive Communication (RO-MAN), New Delhi, India.10.1109/RO-MAN46459.2019.8956423 ↗
5. Guo, J., Qi, L., Guo, S., Meng, C., and Zhan, Q. (2019, January 4–7). Study on Tracking Stability for a Master-Slave Vascular Interventional Robotic System. Proceedings of the 2019 IEEE International Conference on Mechatronics and Automation (ICMA), Tianjin, China.10.1109/ICMA.2019.8816593 ↗
6. Ju, H., Zhang, J., An, G., Pei, X., and Xing, G. (2008, January 21–24). A robot-assisted system for minimally invasive spine surgery of percutaneous vertebroplasty based on CT images. Proceedings of the 2008 IEEE Conference on Robotics, Automation and Mechatronics, Chengdu, China.10.1109/RAMECH.2008.4681395 ↗
7. Teleoperated Echograph and Probe Transducer for Remote Ultrasound Investigation on Isolated Patients (Study of 100 Cases)10.1089/tmj.2015.0186 ↗
8. Arbeille, P., Zuj, K., Saccomandi, A., Andre, E., De La Porte, C., and Georgescu, M. (2016). Tele-Operated Echography and Remote Guidance for Performing Tele-Echography on Geographically Isolated Patients. J. Clin. Med., 5.10.3390/jcm5060058 ↗
9. The TERESA project: From space research to ground tele-echography10.1108/01439910310457742 ↗
10. World Health Organization (2020, June 06). Q&A on Coronaviruses. Available online: https://www.who.int/news-room/q-a-detail/q-a-coronaviruses.
11. Loibner, M., Hagauer, S., Schwantzer, G., Berghold, A., and Zatloukal, K. (2019). Limiting factors for wearing personal protective equipment (PPE) in a health care environment evaluated in a randomised study. PLoS ONE, 14.10.1371/journal.pone.0210775 ↗
12. (2020, September 05). Centers for Disease Control and Prevention Clinical Questions about COVID-19: Questions and Answers, Available online: https://www.cdc.gov/coronavirus/2019-ncov/hcp/faq.html.
13. (2020, September 08). Centers for Disease Control and Prevention Interim Guidelines for Collecting, Handling, and Testing Clinical Specimens from Persons for Coronavirus Disease 2019 (COVID-19), Available online: https://www.cdc.gov/coronavirus/2019-ncov/lab/guidelines-clinical-specimens.html.
14. Clinical application of an intelligent oropharyngeal swab robot: Implication for the COVID-19 pandemic10.1183/13993003.01912-2020 ↗
15. Merlet, J.P. (2006). Parallel Robots, Springer. [2nd ed.]. Solid Mechanics and Its Applications.
16. Park, F.C. (2015). Parallel Robots. Encycl. Syst. Control, 1031–1036.10.1007/978-1-4471-5058-9_174 ↗
17. How to Obtain a Nasopharyngeal Swab Specimen10.1056/NEJMvcm2010260 ↗
18. Fischer, P., Daniel, R., and Siva, K.V. (1990, January 13–18). Specification and design of input devices for teleoperation. Proceedings of the IEEE International Conference on Robotics and Automation, Cincinnati, OH, USA.
19. Medical telerobotic systems: Current status and future trends10.1186/s12938-016-0217-7 ↗
20. Photo-realistic scene prediction of partially unknown environments for the compensation of time delays in telepresence applications
21. Hauser, K., and Shaw, R. (2020, June 04). How Medical Robots Will Help Treat Patients in Future Outbreaks. IEEE Spectrum 2020. Available online: https://spectrum.ieee.org/automaton/robotics/medical-robots/medical-robots-future-outbreak-response.
22. Kim, C., Ahmed, J.A., Eidex, R.B., Nyoka, R., Waiboci, L.W., Erdman, D., Tepo, A., Mahamud, A.S., Kabura, W., and Nguhi, M. (2011). Comparison of Nasopharyngeal and Oropharyngeal swabs for the diagnosis of eight respiratory viruses by real-time reverse transcription-PCR assays. PLoS ONE, 6.10.1371/journal.pone.0021610 ↗
23. Added value of an oropharyngeal swab in detection of viruses in children hospitalized with lower respiratory tract infection10.1128/JCM.02605-10 ↗