Nonlinear Dynamic Response of a Precast Concrete Building to Sudden Column Removal
Source abstract
Abstract
Robustness of reinforced concrete (RC) structures is an ongoing challenging research topic in the engineering community. During an extreme event, the loss of vertical load-bearing elements can activate large-deformation resisting mechanisms such as membrane and catenary actions in beams and floor slabs of cast-in-situ RC buildings to resist gravity loads. However, few studies have been conducted for precast concrete (PC) buildings, especially focused on the capacity of such structures to withstand column loss scenarios, which mainly relies on connection strength. Additional resistance resource and alternate load paths could be reached via tying systems. In this paper, the progressive collapse resistance of a PC frame building is analyzed by means of nonlinear dynamic finite element analyses focusing on the fundamental roles played by beam-to-column connection strength and tying reinforcement. A simplified modelling approach is illustrated in order to investigate the response of such a structural typology to a number of sudden column-removal scenarios. The relative simplicity of the modelling technique is considered useful for engineering practice, providing new input for further research in this field.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Response to Dynamic Loads · High-Velocity Impact and Material Behavior · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Engineering and Architecture, University of Parma, 43124 Parma, Italy
European Centre for Training and Research in Earthquake Engineering, 27100 Pavia, Italy
Department of Structures for Engineering and Architecture, University of Naples Federico II, 80138 Naples, Italy
References (55)
Show source-provided references
1. Research and practice on progressive collapse and robustness of building structures in the 21st century10.1016/j.engstruct.2018.06.082 ↗
2. (2006). Eurocode 1—Actions on Structures: General Actions—Accidental Actions, European Committee for Standardization. CEN-EC1, EN 1991-1-7.
3. Load-Carrying Mechanism to Resist Progressive Collapse of RC Buildings10.1061/(ASCE)ST.1943-541X.0001046 ↗
4. Effects of rotational capacity and horizontal restraint on development of catenary action in 2-D RC frames10.1016/j.engstruct.2017.09.059 ↗
5. Structural Behavior of RC Beam-Column Subassemblages under a Middle Column Removal Scenario10.1061/(ASCE)ST.1943-541X.0000658 ↗
6. Pham, A.T., and Tan, K.H. (2019). Static and Dynamic Responses of Reinforced Concrete Structures under Sudden Column Removal Scenario Subjected to Distributed Loading. J. Struct. Eng., 145.10.1061/(ASCE)ST.1943-541X.0002214 ↗
7. Experimental Study of Reinforced Concrete Assemblies under a Column Removal Scenario10.14359/51686739 ↗
8. Experimental study on dynamic responses of reinforced concrete frames under sudden column removal applying concentrated loading10.1016/j.engstruct.2017.02.002 ↗
9. Structural Behavior of Reinforced Concrete Frames Subjected to Progressive Collapse10.14359/51689424 ↗
10. Diao, M., Li, Y., Guan, H., Lu, X., and Gilbert, B.P. (2020). Influence of horizontal restraints on the behaviour of vertical disproportionate collapse of RC moment frames. Eng. Fail. Anal., 109.10.1016/j.engfailanal.2019.104324 ↗
11. Experimental Response of Beam-Slab Substructures Subject to Penultimate-External Column Removal10.1061/(ASCE)ST.1943-541X.0001123 ↗
12. Experimental study of beam–slab substructures subjected to a penultimate-internal column loss10.1016/j.engstruct.2013.03.026 ↗
13. Experimental investigation of RC beam-slab substructures against progressive collapse subject to an edge-column-removal scenario10.1016/j.engstruct.2016.07.039 ↗
14. Experimental studies of 3D RC substructures under exterior and corner column removal scenarios10.1016/j.engstruct.2017.07.041 ↗
15. Structure behavior of reinforced concrete beam-slab assemblies subjected to perimeter middle column removal scenario10.1016/j.engstruct.2020.110336 ↗
16. Resilience of Flat Slab Structures in Different Phases of Progressive Collapse10.14359/51688619 ↗
17. Load Transfer and Collapse Resistance of RC Flat Plates under Interior Column Removal Scenario10.1061/(ASCE)ST.1943-541X.0002090 ↗
18. Progressive Collapse Performance of RC Flat Plate Frame Structures10.1061/(ASCE)ST.1943-541X.0000963 ↗
19. Ravasini, S., Scalvenzi, M., Parisi, F., Belletti, B., and Gasperi, A. (2020, January 14–16). Evaluation of structural robustness of precast RC structures. Proceedings of the Italian Concrete Days 2020, Napoli, Italy.
20. Behaviour of precast concrete beam–column sub-assemblages subject to column removal10.1016/j.engstruct.2015.03.027 ↗
21. Progressive Collapse Resistance of Precast Concrete Frames with Discontinuous Reinforcement in the Joint10.1061/(ASCE)ST.1943-541X.0001828 ↗
22. Static load test on progressive collapse resistance of fully assembled precast concrete frame structure10.1016/j.engstruct.2019.109719 ↗
23. Static and dynamic loading tests for precast concrete moment frames under progressive collapse10.1016/j.engstruct.2020.110612 ↗
24. Qian, K., Liang, S.-L., Xiong, X.-Y., Fu, F., and Fang, Q. (2020). Quasi-static and dynamic behavior of precast concrete frames with high performance dry connections subjected to loss of a penultimate column scenario. Eng. Struct., 205.10.1016/j.engstruct.2019.110115 ↗
25. Behavior of wet precast beam column connections under progressive collapse scenario: An experimental study10.1007/s40091-014-0072-3 ↗
26. Experimental and numerical studies of precast connection under progressive collapse scenario
27. Progressive collapse test of assembled monolithic concrete frame spatial substructures with different anchorage methods in the beam–column joint10.1177/1369433219900679 ↗
28. Wang, F., Yang, J., and Shah, S. (2020). Effect of Horizontal Restraints on Progressive Collapse Resistance of Precast Concrete Beam-Column Framed Substructures. KSCE J. Civ. Eng., 879–889.10.1007/s12205-020-1035-9 ↗
29. Experimental Investigation on Vulnerability of Precast RC Beam-column Joints to Progressive Collapse10.1007/s12205-018-1518-0 ↗
30. Investigation into Resilience of Precast Concrete Floors against Progressive Collapse10.14359/51710878 ↗
31. Performance of Precast Concrete Substructures with Dry Connections to Resist Progressive Collapse10.1061/(ASCE)CF.1943-5509.0001147 ↗
32. Qian, K., and Li, B. (2019). Strengthening and Retrofitting Precast Concrete Buildings to Mitigate Progressive Collapse Using Externally Bonded GFRP Strips. J. Compos. Constr., 23.10.1061/(ASCE)CC.1943-5614.0000943 ↗
33. Effect of floor joint design on catenary actions of precast floor slab system10.1016/j.engstruct.2017.09.017 ↗
34. (2012). Design of Precast Concrete Structures Against Accidental Actions, International Federation for Structural Concrete. fib Bulletin 63.
35. (2008). Structural Connections for Precast Concrete Buildings, International Federation for Structural Concrete. fib Bulletin 43.
36. Influence of seismic design criteria on blast resistance of RC framed buildings: A case study10.1016/j.engstruct.2012.05.046 ↗
37. A non-emulative moment connection for progressive collapse resistance in precast concrete building frames10.1016/j.engstruct.2018.10.027 ↗
38. Experimental study of a novel multi-hazard resistant prefabricated concrete frame structure10.1016/j.soildyn.2018.04.011 ↗
39. Seismic performance of precast reinforced concrete buildings with dowel pin connections10.1016/j.jobe.2016.06.013 ↗
40. Seismic Performance of Precast Industrial Facilities Following Major Earthquakes in the Italian Territory10.1061/(ASCE)CF.1943-5509.0000617 ↗
41. Performance of dowel beam-to-column connections for precast concrete systems under seismic loads: A review10.1016/j.conbuildmat.2019.117582 ↗
42. Extreme response of reinforced concrete buildings through fiber force-based finite element analysis10.1016/j.engstruct.2014.03.020 ↗
43. Performance limit states for progressive collapse analysis of reinforced concrete framed buildings10.1002/suco.201800039 ↗
44. (2009). Design of Buildings to Resist Progressive Collapse, Department of Defense Unified Facilities Criteria. UFC 4-023-03.
45. (2002). EN 1990 Eurocode 0: Basis of Structural Design, European Committee for Standardization.
46. Seismosoft (2020, December 31). Seismostruct—A Computer Program for Static and Dynamic Nonlinear Analysis of Framed Structures. Available online: https://seismosoft.com/.
47. Fibre beam-column model for non-linear analysis of R/C frames: Part I. Formulation10.1002/(SICI)1096-9845(199607)25:7<711::AID-EQE576>3.0.CO;2-9 ↗
48. Theoretical Stress-Strain Model for Confined Concrete10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
49. Compressive behaviour of concrete at high strain rates10.1007/BF02472016 ↗
50. Analysis of a semi-rigid connection for precast concrete10.1680/stbu.2009.163.1.41 ↗
51. Can precast concrete structures be designed as semi-rigid frames? Part 1—The experimental evidence
52. Can precast concrete structures be designed as semi-rigid frames? Part 2—Analytical equations & column effective length factors
53. (2004). EN 1998: Eurocode 8: Design of Structures for Earthquake Resistance—Part 1: General Rules, Seismic Actions and Rules for Buildings, European Committee for Standardization. CEN-EC8.
54. Belletti, B., Franceschini, L., and Ravasini, S. (2019, January 26–28). Tie force method for reinforced concrete structures. Proceedings of the International fib Symposium on Conceptual Design of Structures, Madrid, Spain.
55. Progressive collapse assessment of gravity-load designed European RC buildings under multi-column loss scenarios10.1016/j.engstruct.2019.110001 ↗