journal article·2019-07-10Open access

A Comparative Study of the Fitness and Trueness of a Three-Unit Fixed Dental Prosthesis Fabricated Using Two Digital Workflows

Daehee Jang, Keunbada Son, Kyu-bok Lee

Applied Sciences· Volume 9· Issue 14

Abstract

The purpose of this study was to measure and correlate the fitness and trueness of a 3-unit fixed dental prosthesis (FDP) fabricated using two digital workflows. The 3-unit FDPs were fabricated using two digital workflows (N = 15). The digital workflows were divided into chairside (closed type) and in-lab (open type) groups. The scanning, computer-aided design (CAD), and computer-aided manufacturing (CAM) processes were conducted with 3shape E1 scanner, exocad CAD software, and DDS EZIS HM, respectively, in the in-lab group; and with CEREC omnicam intraoral scanner, CEREC CAD software, and CEREC MC XL, respectively, in the chairside group. The fitness of the fabricated 3-unit FDPs was evaluated by scanning the silicone replica of the cement space and analyzing the thickness of the silicone replica in the three-dimensional (3D) inspection software (Geomagic control X). The trueness of the milling unit was analyzed by 3D analysis of the CAD reference model, which is the design file of the 3-unit FDP, and the CAD test model, which is the scanned file of the 3-unit FDP. In the statistical analysis, comparison of the two groups was conducted by Mann–Whitney U test, and the correlation between the fitness and trueness was conducted by Pearson correlation test (α = 0.05). The marginal and internal fit were significantly lower in the in-lab group at all measurement positions (p < 0.001). The trueness of the milling unit was significantly higher in the in-lab group compared to the chairside group (p < 0.001). There was a positive correlation between the trueness and internal fit (correlation coefficient = 0.621) in the in-lab group (p = 0.013). The use of appropriate equipment in an in-lab (open type) digital workflow enables a better fabrication of 3-unit FDPs than a chairside (closed type) digital workflow, and poor trueness on the inner surface of the crown adversely affects the internal fit.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Prosthodontics, School of Dentistry, Kyungpook National University, 2177 Dalgubeol-daero, Jung-gu, Daegu 41940, Korea

Department of Dental Science, Graduate School, Kyungpook National University, 2177 Dalgubeol-daero, Jung-gu, Daegu 41940, Korea

Advanced Dental Device Development Institute, Kyungpook National University, 2177 Dalgubeol-daero, Jung-gu, Daegu 41940, Korea

Funding

The Ministry of Trade, Industry & Energy (MOTIE, Korea) · Korea Institute for Advancement of Technology (KIAT) · Institute for Information & Communications Technology Promotion (IITP)

References (35)

Show source-provided references
1. Feasibility of using an intraoral scanner for a complete-arch digital scan10.1016/j.prosdent.2018.07.014 ↗
2. Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses10.4047/jap.2019.11.2.138 ↗
3. Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards10.4047/jap.2018.10.5.335 ↗
4. Evaluation of the reproducibility of various abutments using a blue light model scanner10.4047/jap.2018.10.4.328 ↗
5. A comparison of the accuracy of intraoral scanners using an intraoral environment simulator10.4047/jap.2018.10.1.58 ↗
6. Arezoobakhsh, A., Shayegh, S.S., Ghomi, A.J., and Hakimaneh, S.M.R. (2019). Comparison of marginal and internal fit of 3-unit zirconia frameworks fabricated with CAD-CAM technology using direct and indirect digital scans. J. Prosthet. Dent.10.1016/j.prosdent.2018.10.023 ↗
7. Park, J.-M., Kim, R.J.-Y., and Lee, K.-W. (2019). Comparative reproducibility analysis of 6 intraoral scanners used on complex intracoronal preparations. J. Prosthet. Dent.10.1016/j.prosdent.2018.10.025 ↗
8. Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas10.4047/jap.2018.10.3.236 ↗
9. Alqarni, H., AlHelal, A., Kattadiyil, M.T., and Goodacre, C.J. (2019). Selective implant scan body modification to restore severely tilted adjacent implants: A completely digital workflow. J. Prosthet. Dent.10.1016/j.prosdent.2019.04.012 ↗
10. Mangano, F., Gandolfi, A., Luongo, G., and Logozzo, S. (2017). Intraoral scanners in dentistry: A review of the current literature. BMC Oral Health, 17.10.1186/s12903-017-0442-x ↗
11. Sadid-Zadeh, R., Katsavochristou, A., Squires, T., and Simon, M. (2019). Accuracy of marginal fit and axial wall contour for lithium disilicate crowns fabricated using three digital workflows. J. Prosthet. Dent.10.1016/j.prosdent.2018.11.003 ↗
12. Son, K., Lee, S., Kang, S.H., Park, J., Lee, K.-B., and Jeon, M. (2019). A Comparison Study of Marginal and Internal Fit Assessment Methods for Fixed Dental Prostheses. J. Clin. Med., 8.10.3390/jcm8060785 ↗
13. Son, K., Yu, B.Y., Yoon, T.H., and Lee, K.-B. (2019). Comparative Study of the Trueness of the Inner Surface of Crowns Fabricated from Three Types of Lithium Disilicate Blocks. Appl. Sci., 9.10.3390/app9091798 ↗
14. Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study10.4047/jap.2018.10.2.128 ↗
15. Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs10.4047/jap.2019.11.2.105 ↗
16. Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown10.4047/jap.2015.7.4.271 ↗
17. Evaluation of different approaches for using a laser scanner in digitization of dental impressions10.4047/jap.2014.6.1.22 ↗
18. Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems10.4047/jap.2016.8.6.439 ↗
19. Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique10.4047/jap.2018.10.5.354 ↗
20. Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study10.4047/jap.2017.9.4.252 ↗
21. Trueness analysis of zirconia crowns fabricated with 3-dimensional printing10.1016/j.prosdent.2018.04.012 ↗
22. In vivo wear determination of novel CAD/CAM ceramic crowns by using 3D alignment10.4047/jap.2019.11.2.120 ↗
23. In-vitro performance and fracture strength of thin monolithic zirconia crowns10.4047/jap.2018.10.2.79 ↗
24. In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses10.4047/jap.2017.9.4.244 ↗
25. Lo Russo, L., Caradonna, G., Biancardino, M., De Lillo, A., Troiano, G., and Guida, L. (2019). Digital versus conventional workflow for the fabrication of multiunit fixed prostheses: A systematic review and meta-analysis of vertical marginal fit in controlled in vitro studies. J. Prosthet. Dent.10.1016/j.prosdent.2018.12.001 ↗
26. The fit of cobalt–chromium three-unit fixed dental prostheses fabricated with four different techniques: A comparative in vitro study10.1016/j.dental.2010.11.015 ↗
27. In Vitro Comparison of Marginal and Internal Fit of Press-on-Metal Ceramic (PoM) Restorations with Zirconium-Supported and Conventional Metal Ceramic Fixed Partial Dentures Before and After Veneering10.1111/jopr.12229 ↗
28. Comparison of marginal and internal fit of press-on-metal and conventional ceramic systems for three-and four-unit implant-supported partial fixed dental prostheses: An in vitro study10.1016/j.prosdent.2015.01.002 ↗
29. Vertical microgap and passivity of fit of three-unit implant-supported frameworks fabricated using different techniques
30. Comparative analysis on reproducibility among 5 intraoral scanners: Sectional analysis according to restoration type and preparation outline form10.4047/jap.2016.8.5.354 ↗
31. Trueness of milled prostheses according to number of ball-end mill burs10.1016/j.prosdent.2015.10.014 ↗
32. Trueness of four different milling procedures used in dental CAD/CAM systems10.1007/s00784-016-1916-y ↗
33. Evaluation of dimensional accuracy of dental bridges manufactured with conventional casting technique and CAD/CAM system with Ceramill Sintron blocks using CMM10.15171/joddd.2018.041 ↗
34. A three-dimensional evaluation of a laser scanner and a touch-probe scanner10.1016/j.prosdent.2006.01.003 ↗
35. Dimitrova, M. (2017). A 3D Evaluation of the Repeatability of Accuracy in Optical and Contact Scanners, Cardiff Metropolitan University.