Design and Biomechanical Verification of Additive Manufactured Composite Spinal Cage Composed of Porous Titanium Cover and PEEK Body
Source abstract
Abstract
Incidents of lumbar degenerative diseases, such as spinal stenosis and degenerative spondylolisthesis, are increasing due to the aging population, and as a result, posterior lumbar interbody fusion (PLIF) is widely used. However, the interbody fusion cage used in the fusion surgery has been reported to cause subsidence in the fusion cage of the titanium material and bone nonunion in the case of the polyetheretherketone (PEEK) material cage. Therefore, we aim to reduce the possibility of subsidence of the spinal fusion cage through its elastic modulus difference with the cortical bone of the vertebral body. For the vertebral end plate, which is related to the fusion rate, we also aim to design a new composite vertebral cage, which integrates a cover of porous structure using the additive manufacturing method of titanium alloy to fabricate a prototype, and to biomechanically verify the prototype. The method was as follows. In order to find a similar pore size of human cancellous bone, the pore size was adjusted and the results were measured with SEM. The pore size of each surface was measured individually and the mean value was calculated. Next, an animal experiment was conducted to confirm the degree of fusion of each structural type, and prototypes of various structures were fabricated. The degree of fusion was confirmed by a push down test. A prototype of the fusion cage composed of titanium and PEEK material was fabricated, and the possibility of subsidence by existence of porous structure was confirmed by using the lumbar spine finite element model. Then, the prototype was compared with the composite fusion cage developed by ASTM F2077 and ASTM F2267 methods, and with the commercial PEEK and titanium cages. As a result, the correlation between bone fusion and the porous structure, as well as size of the spine fusion cage composing the composite for porous structure and elasticity, was confirmed. Type 3 structures showed the best performance in bone fusion and the pore size of 1.2 mm was most suitable. In addition, the likelihood of subsidence of a cage with a porous structure was considered to be lower than that of a cage with a solid structure. When the new composite cage combined with two composites was compared with commercial products to verify, the performance was better than that of the existing PEEK material. The subsidence result was superior to the titanium product and showed similar results to PEEK products. In conclusion, the performance value was superior to the existing PEEK material, and the subsidence result was superior to the titanium product and was similar to the PEEK product, and thus, performance-wise, it is concluded that the PEEK product can be completely replaced with the new product.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Spine and Intervertebral Disc Pathology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Korea National University of Transportation, Chungju-si 27469, Korea
Department of Biomedical Engineering, College of Biomedical Science & Engineering, Inje University, Gyeongnam 50834, Korea
References (24)
Show source-provided references
1. The correlation between cage subsidence, bone mineral density, and clinical results in posterior lumbar interbody fusion10.1097/BSD.0000000000000315 ↗
2. Comparison of one-level posterior lumbar interbody fusion performed with a minimally invasive approach or a traditional open approach10.1097/01.brs.0000256473.49791.f4 ↗
3. Posterior Lumbar Interbody Fusion and Plates10.1097/00003086-198802000-00013 ↗
4. A polyaryletherketone biomaterial for use in medical implant applications
5. Cabraja, M., Oezdemir, S., Koeppen, D., and Kroppenstedt, S. (2012). Anterior cervical discectomy and fusion: comparison of titanium and polyetheretherketone cages. BMC Musculoskelet. Disord., 13.10.1186/1471-2474-13-172 ↗
6. Fabrication of porous titanium scaffolds with high compressive strength using camphene-based freeze casting10.1016/j.matlet.2009.03.056 ↗
7. Investigation of hydroxyapatite coated polyether ether ketone composites by gas plasma sprays10.1016/j.surfcoat.2009.02.115 ↗
8. Stress Analysis of the Lumbar Disc-Body Unit in Compression A Three-Dimensional Nonlinear Finite Element Study10.1097/00007632-198403000-00003 ↗
9. The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties10.1016/j.biomaterials.2009.12.030 ↗
10. Development and perspective of biomaterials for spinal fusion
11. Biomedical applications of titanium and its alloys10.1007/s11837-008-0031-1 ↗
12. In vitro and in vivo biocompatibility of Ti-6Al-4V titanium alloy and UHMWPE polymer for total hip replacement10.7603/s40730-016-0014-8 ↗
13. In Situ Contact Analysis of the Prosthesis Components of Prodisc-L in Lumbar Spine Following Total Disc Replacement10.1097/BRS.0b013e3181ae23d1 ↗
14. ASTM F2077-18 (2018). Test Methods for Intervertebral Body Fusion Devices, ASTM International.
15. ASTM F2267-04 (2018). Standard Test Method for Measuring Load Induced Subsidence of Intervertebral Body Fusion Device Under Static Axial Compression, ASTM International.
16. Porous titanium-coated polyetheretherketone implants exhibit an improved bone–implant interface: an in vitro and in vivo biochemical, biomechanical, and histological study10.2147/MDER.S180482 ↗
17. Finite element analysis of cage subsidence in cervical interbody fusion
18. Elastic modulus and stress analysis of porous titanium parts fabricated by selective laser melting
19. Hybrid multidirectional test method to evaluate spinal adjacent-level effects10.1016/j.clinbiomech.2006.08.006 ↗
20. Determination of trunk muscle forces for flexion and extension by using a validated finite element model of the lumbar spine and measured in vivo data10.1016/j.jbiomech.2005.02.019 ↗
21. White, A., and Panjabi, M.M. (1990). Clinical Biomechanics of the Spine, JB Lippincott Co.. [2nd ed.].
22. Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis10.1007/s00586-002-0505-8 ↗
23. Hench, L.L., and Wilson, J. (1993). An Introduction to Bioceramics., World Scientific.10.1142/2028 ↗
24. Intervertebral Disc Degeneration Can Lead to “Stress-Shielding” of the Anterior Vertebral Body10.1097/01.BRS.0000119401.23006.D2 ↗