Computational Fluid Dynamic Accuracy in Mimicking Changes in Blood Hemodynamics in Patients with Acute Type IIIb Aortic Dissection Treated with TEVAR
Source abstract
Abstract
Background: We aimed to verify the accuracy of the Computational Fluid Dynamics (CFD) algorithm for blood flow reconstruction for type IIIb aortic dissection (TBAD) before and after thoracic endovascular aortic repair (TEVAR). Methods: We made 3D models of the aorta and its branches using pre- and post-operative CT data from five patients treated for TBAD. The CFD technique was used to quantify the displacement forces acting on the aortic wall in the areas of endograft, mass flow rate/velocity and wall shear stress (WSS). Calculated results were verified with ultrasonography (USG-Doppler) data. Results: CFD results indicated that the TEVAR procedure caused a 7-fold improvement in overall blood flow through the aorta (p = 0.0001), which is in line with USG-Doppler data. A comparison of CFD results and USG-Doppler data indicated no significant change in blood flow through the analysed arteries. CFD also showed a significant increase in flow rate for thoracic trunk and renal arteries, which was in accordance with USG-Doppler data (accuracy 90% and 99.9%). Moreover, we observed a significant decrease in WSS values within the whole aorta after TEVAR compared to pre-TEVAR (1.34 ± 0.20 Pa vs. 3.80 ± 0.59 Pa, respectively, p = 0.0001). This decrease was shown by a significant reduction in WSS and WSS contours in the thoracic aorta (from 3.10 ± 0.27 Pa to 1.34 ± 0.11Pa, p = 0.043) and renal arteries (from 4.40 ± 0.25 Pa to 1.50 ± 0.22 Pa p = 0.043). Conclusions: Post-operative remodelling of the aorta after TEVAR for TBAD improved hemodynamic patterns reflected by flow, velocity and WSS with an accuracy of 99%.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Aortic Disease and Treatment Approaches · Aortic aneurysm repair treatments · Cardiac Valve Diseases and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Process and Environmental Engineering, Lodz University of Technology, Wolczanska 213, 90-924 Lodz, Poland
Department of Surgery, Division of Vascular Surgery, Medical University of Vienna, Spitalgasse 23, 1090 Wien, Austria
Department of Medical Biotechnology, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, Gronostajowa 7, 30-387 Krakow, Poland
References (39)
Show source-provided references
1. Thoracic aortic aneurysm and dissection: Increasing prevalence and improved outcomes reported in a nationwide population-based study of more than 14,000 cases from 1987 to 200210.1161/CIRCULATIONAHA.106.630400 ↗
2. The International Registry of Acute Aortic Dissection (IRAD): New insights into an old disease10.1001/jama.283.7.897 ↗
3. Aortic dissection with the entrance tear in the descending thoracic aorta. Analysis of 40 necropsy patients10.1097/00000658-199104000-00011 ↗
4. Clinical profiles and outcomes of acute type B aortic dissection in the current era: Lessons from the International Registry of Aortic Dissection (IRAD)10.1161/01.cir.0000087386.07204.09 ↗
5. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement10.1056/NEJM199905203402003 ↗
6. Endovascular stent-graft placement for the treatment of acute aortic dissection10.1056/NEJM199905203402004 ↗
7. Hemodynamics and the vascular endothelial cytoskeleton10.1083/jcb.105.1.291 ↗
8. On the potentialities of 3D-1D coupled models in hemodynamics simulations10.1016/j.jbiomech.2009.01.034 ↗
9. Polanczyk, A., Podgorski, M., Wozniak, T., Stefanczyk, L., and Strzelecki, M. (2018). Computational Fluid Dynamics as an Engineering Tool for the Reconstruction of Hemodynamics after Carotid Artery Stenosis Operation: A Case Study. Medicina, 54.10.3390/medicina54030042 ↗
10. Analysis of flow patterns in a patient-specific aortic dissection model10.1115/1.4000964 ↗
11. 3D Blood Vessels Reconstruction Based on Segmented CT Data for Further Simulations of Hemodynamic in Human Artery Branches10.1515/fcds-2017-0018 ↗
12. Unsteady and three-dimensional simulation of blood flow in the human aortic arch10.1115/1.1487357 ↗
13. A computational study on the biomechanical factors related to stent-graft models in the thoracic aorta10.1007/s11517-008-0361-8 ↗
14. Investigation of hemodynamics in the development of dissecting aneurysm within patient-specific dissecting aneurismal aortas using computational fluid dynamics (CFD) simulations10.1016/j.jbiomech.2010.12.014 ↗
15. Computational approach to optimal transport network construction in biomechanics10.1007/978-3-540-24709-8_51 ↗
16. Analysis of type I endoleaks in a stented abdominal aortic aneurysm10.1016/j.medengphy.2008.03.005 ↗
17. Patient-Based Abdominal Aortic Aneurysm Rupture Risk Prediction with Fluid Structure Interaction Modeling10.1007/s10439-010-0094-3 ↗
18. Reconstruction and finite element mesh generation of abdominal aortic aneurysms from computerized tomography angiography data with minimal user interactions10.1109/TMI.2009.2039579 ↗
19. Polanczyk, A., Klinger, M., Nanobachvili, J., Huk, I., and Neumayer, C. (2018). Artificial Circulatory Model for Analysis of Human and Artificial Vessels. Appl. Sci., 8.10.3390/app8071017 ↗
20. MRI measurement of time-resolved wall shear stress vectors in a carotid bifurcation model, and comparison with CFD predictions10.1002/jmri.10243 ↗
21. Reporting standards for thoracic endovascular aortic repair (TEVAR)10.1016/j.jvs.2010.07.008 ↗
22. Polanczyk, A., Podyma, M., Trebinski, L., Chrzastek, J., Zbicinski, I., and Stefanczyk, L. (2016). A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts. PLoS ONE, 11.10.1371/journal.pone.0153332 ↗
23. Evaluating an algorithm for 3D reconstruction of blood vessels for further simulations of hemodynamic in human artery branches
24. Effects of stent-graft geometry and blood hematocrit on hemodynamic in Abdominal Aortic Aneurysm
25. Polanczyk, A., Piechota-Polanczyk, A., and Stefanczyk, L. (2017). A new approach for the pre-clinical optimization of a spatial configuration of bifurcated endovascular prosthesis placed in abdominal aortic aneurysms. PLoS ONE, 12.10.1371/journal.pone.0182717 ↗
26. Simulation and validation of arterial ultrasound imaging and blood flow10.1016/j.ultrasmedbio.2007.10.017 ↗
27. A 3D model of thrombus formation in a stent-graft after implantation in the abdominal aorta10.1016/j.jbiomech.2014.12.033 ↗
28. Doppler ultrasound and renal artery stenosis: An overview10.1016/j.jus.2009.09.006 ↗
29. Predicting flow in aortic dissection: Comparison of computational model with PC-MRI velocity measurements10.1016/j.medengphy.2014.07.006 ↗
30. Multi-modality image-based computational analysis of haemodynamics in aortic dissection10.1007/s10237-015-0729-2 ↗
31. The Potential of Computational Fluid Dynamics Simulation on Serial Monitoring of Hemodynamic Change in Type, B. Aortic Dissection10.1007/s00270-016-1352-z ↗
32. Wall shear stress and strain modulate experimental aneurysm cellularity10.1016/S0741-5214(03)70052-4 ↗
33. An in vitro phantom study on the influence of tear size and configuration on the hemodynamics of the lumina in chronic type B. aortic dissections10.1016/j.jvs.2012.07.008 ↗
34. Computational Study of Anatomical Risk Factors in Idealized Models of Type, B. Aortic Dissection10.1016/j.ejvs.2016.07.025 ↗
35. Longitudinal computational fluid dynamics study of aneurysmal dilatation in a chronic DeBakey type III aortic dissection10.1016/j.jvs.2012.02.064 ↗
36. The role of geometric parameters in the prediction of abdominal aortic aneurysm wall stress10.1016/j.ejvs.2009.09.026 ↗
37. Vessel asymmetry as an additional diagnostic tool in the assessment of abdominal aortic aneurysms10.1016/j.jvs.2008.08.064 ↗
38. Lagrangian analysis of hemodynamics data from FSI simulation10.1002/cnm.2523 ↗
39. Newtonian viscosity model could overestimate wall shear stress in intracranial aneurysm domes and underestimate rupture risk10.1136/neurintsurg-2011-010089 ↗