journal article·2021-04-22Open access

Inlay-Retained Dental Bridges—A Finite Element Analysis

Monica Tatarciuc, George Alexandru Maftei, Anca Vitalariu, Ionut Luchian, Ioana Martu, Diana Diaconu-Popa

Applied Sciences· Volume 11· Issue 9

Abstract

Inlay-retained dental bridges can be a viable minimally invasive alternative when patients reject the idea of implant therapy or conventional retained full-coverage fixed dental prostheses, which require more tooth preparation. Inlay-retained dental bridges are indicated in patients with good oral hygiene, low susceptibility to caries, and a minimum coronal tooth height of 5 mm. The present study aims to evaluate, through the finite element method (FEM), the stability of these types of dental bridges and the stresses on the supporting teeth, under the action of masticatory forces. The analysis revealed the distribution of the load on the bridge elements and on the retainers, highlighting the areas of maximum pressure. The results of our study demonstrate that the stress determined by the loading force cannot cause damage to the prosthetic device or to abutment teeth. Thus, it can be considered an optimal economical solution for treating class III Kennedy edentation in young patients or as a provisional pre-implant rehabilitation option. However, special attention must be paid to its design, especially in the connection area between the bridge elements, because the connectors and the retainers represent the weakest parts.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Dental Technology, “Grigore T. Popa” University of Medicine and Pharmacy, 16 Universitatii Str., 700115 Iasi, Romania

Department of Oral Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 16 Universitatii Str., 700115 Iasi, Romania

Department of Periodontology, “Grigore T. Popa” University of Medicine and Pharmacy, 16 Universitatii Str., 700115 Iasi, Romania

References (33)

Show source-provided references
1. Selected applications for current polymers in prosthetic dentistry-state of the art10.2174/0929867325666180510142937 ↗
2. Wieckiewicz, M., Opitz, V., Richter, G., and Boening, K.W. (2014). Physical properties of polyamide-12 versus PMMA denture base material. Bio. Med. Res. Int.10.1155/2014/150298 ↗
3. Campaner, L.M., Silveira, M.P., de Andrade, G.S., Borges, A.L., Bottino, M.A., Dal Piva, A.M., Lo Giudice, R., Ausiello, P., and Tribst, J.P. (2021). Influence of Polymeric Restorative Materials on the Stress Distribution in Posterior Fixed Partial Dentures: 3D Finite Element Analysis. Polymers, 13.10.3390/polym13050758 ↗
4. Inlay-retained zirconia fixed dental prosthesis: Clinical and laboratory procedures
5. Inlay-Retained Fixed Dental Prosthesis: A Clinical Option Using Monolithic Zirconia
6. Influence of connector width on the stress distribution of posterior bridges under loading
7. Effect of silver nanoparticles incorporation in dental resins on stress distribution- Finite Element Analysis
8. Bandela, V., and Kanaparthi, S. (2020). Finite Element Analysis and Its Applications in Dentistry. Finite Element Methods and Their Applications, IntechOpen.10.5772/intechopen.94064 ↗
9. 2D-Finite element analysis of inlay-, onlay bridges with using various materials
10. Influence of Surface Area and Geometry of Specimens on Bond Strength in a Microtensile Test: An Analysis by the Three-Dimensional Finite Element Method10.1111/j.1532-849X.2011.00743.x ↗
11. Biological effect of the abutment material on the stability of peri-implant marginal bone levels: A systematic review and meta-analysis10.1111/clr.13293 ↗
12. Cosola, S., Marconcini, S., Boccuzzi, M., Menchini Fabris, G.B., Covani, U., Peñarrocha-Diago, M., and Peñarrocha-Oltra, D. (2020). Radiological Outcomes of Bone-Level and Tissue-Level Dental Implants: Systematic Review. Int. J Environ. Res. Public Health., 17.10.3390/ijerph17186920 ↗
13. A new design for posterior inlay-retained fixed partial denture10.1016/j.jpor.2012.09.005 ↗
14. Single-tooth replacement: Factors affecting different prosthetic treatment modalities
15. Implant-supported provisional prosthesis facilitated the minor revision of occlusion and incisor exposure after orthognathic surgery of extended oligodontia in maxilla10.1016/j.jds.2020.01.001 ↗
16. A systematic review of the survival and complication rates of inlay-retained fixed dental prostheses10.1016/j.jdent.2017.02.006 ↗
17. Bömicke, W., Rathmann, F., Pilz, M., Bermejo, J.L., Waldecker, M., Ohlmann, B., Rammelsberg, P., and Zenthöfer, A. (2020). Clinical Performance of Posterior Inlay-Retained and Wing-Retained Monolithic Zirconia Resin-Bonded Fixed Partial Dentures: Stage One Results of a Randomized Controlled Trial. J. Prosthodont, 1–10.10.1111/jopr.13258 ↗
18. The all-ceramic, inlay supported fixed partial denture. Part 2. Fixed partial denture design: A finite element analysis10.1111/j.1834-7819.2011.01341.x ↗
19. In vitro comparison of the load-bearing capacity of ceramic and metal-ceramic resin-bonded fixed dental prostheses in the posterior region10.1016/j.prosdent.2017.03.006 ↗
20. Fracture Resistance of Three Ceramic Inlay-Retained Fixed Partial Denture Designs. An In Vitro Comparative Study10.1111/j.1532-849X.2010.00621.x ↗
21. In vitro fracture resistance of posterior metal-ceramic and all-ceramic inlay-retained resin-bonded fixed partial dentures10.1016/j.prosdent.2004.07.001 ↗
22. Comparison between two materials for the fabrication of modified design for posterior inlay-retained fixed dental prosthesis: A finite element study10.4103/jioh.jioh_246_17 ↗
23. Influence of restorative material and cement on the stress distribution of posterior resin-bonded fixed dental prostheses: 3D finite element analysis10.1016/j.jmbbm.2019.05.004 ↗
24. Evaluation of Stress Distribution in Tooth-Supported Fixed Dental Prostheses Made of Translucent Zirconia with Variations in Framework Designs: A Three-Dimensional Finite Element Analysis10.1111/jopr.13146 ↗
25. Malysa, A., Wezgowiec, J., Orzeszek, S., Florjanski, W., Zietek, M., and Wieckiewicz, M. (2021). Effect of Different Surface Treatment Methods on Bond Strength of Dental Ceramics to Dental Hard Tissues: A Systematic Review. Molecules, 26.10.3390/molecules26051223 ↗
26. Indirect composite veneers as a social therapeutic solution. A case report
27. Load to failure of three different monolithic zirconia inlay-retained fixed dental prosthesis designs with three surface treatments10.14295/bds.2020.v23i2.1896 ↗
28. Thermal stress analysis by finite elements of a metal-ceramic dental bridge during the cooling phase of a glaze treatment10.1016/j.jmbbm.2020.103661 ↗
29. Cosola, S., Toti, P., Peñarrocha-Diago, M., Covani, U., Brevi, B.C., and Peñarrocha-Oltra, D. (2021). Standardization of three-dimensional pose of cylindrical implants from intraoral radiographs: A preliminary study. BMC Oral Health., 21.10.1186/s12903-021-01448-9 ↗
30. Comparison of radiographic bone height assessments in panoramic and intraoral radiographs of implant patients
31. Influence of connector dimensions on the stress distribution of monolithic zirconia and lithium-di-silicate inlay retained fixed dental prostheses—A 3D finite element analysis10.1016/j.tdj.2015.01.001 ↗
32. Bond strength evaluation of inlay-retained resin-bonded fixed partial dentures with two different cavity designs and two different adhesive systems: In vitro study10.2478/bjdm-2020-0004 ↗
33. AFM comparative study of root surface morphology after three methods of scaling