Respiration Monitoring for Premature Neonates in NICU

Yue Sun, Wenjin Wang, Xi Long, Mohammed Meftah, Tao Tan, Caifeng Shan, Ronald M. Aarts, Peter H. N. de With

Applied Sciences· Volume 9· Issue 23

Abstract

In this paper, we investigate an automated pipeline to estimate respiration signals from videos for premature infants in neonatal intensive care units (NICUs). Two flow estimation methods, namely the conventional optical flow- and deep learning-based flow estimation methods, were employed and compared to estimate pixel motion vectors between adjacent video frames. The respiratory signal is further extracted via motion factorization. The proposed methods were evaluated by comparing our automated extracted respiration signals to that extracted from chest impedance on videos of five premature infants. The overall average cross-correlation coefficients are 0.70 for the optical flow-based method and 0.74 for the deep flow-based method. The average root mean-squared errors are 6.10 and 4.55 for the optical flow- and the deep flow-based methods, respectively. The experimental results are promising for further investigation and clinical application of the video-based respiration monitoring method for infants in NICUs.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Indoor and Outdoor Localization Technologies · Healthcare Technology and Patient Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical Engineering, Eindhoven University of Technology, 5612 WH Eindhoven, The Netherlands

Philips Research, High Tech Campus 34, 5656 AE Eindhoven, The Netherlands

References (29)

Show source-provided references
2. Periodic breathing of premature infants10.1016/S0022-3476(64)80185-2 ↗
3. The relationship between bradycardia, apnea, and hypoxemia in preterm infants10.1203/00006450-199308000-00007 ↗
4. Behavioural state cycles in abnormal infants10.1111/j.1469-8749.1973.tb05171.x ↗
5. The behavioural states of the newborn infant (a review)10.1016/0006-8993(74)90454-5 ↗
6. Disruption of barrier function in neonatal skin associated with adhesive removal10.1016/S0022-3476(97)80060-1 ↗
7. Skin care for preterm and term neonates10.1111/j.1365-2230.2009.03424.x ↗
8. Contactless monitoring for sleep disordered-breathing, respiratory and cardiac co-morbidity in an elderly independent living cohort
9. A non-contact vital signs monitor10.1615/CritRevBiomedEng.v28.i12.290 ↗
10. Design and Implementation of a Noncontact Sleep Monitoring System Using Infrared Cameras and Motion Sensor10.1109/TIM.2017.2779358 ↗
11. De Chazal, P., O’Hare, E., Fox, N., and Heneghan, C. (2008, January 20–25). Assessment of sleep/wake patterns using a non-contact biomotion sensor. Proceedings of the 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, BC, Canada.10.1109/IEMBS.2008.4649203 ↗
12. Gupta, P., Bhowmick, B., and Pal, A. (2017, January 17–20). Accurate heart-rate estimation from face videos using quality-based fusion. Proceedings of the IEEE International Conference on Image Processing (ICIP), Beijing, China.10.1109/ICIP.2017.8297060 ↗
13. Estimation of Respiratory Pattern From Video Using Selective Ensemble Aggregation10.1109/TSP.2017.2664048 ↗
14. Unobtrusive sleep state measurements in preterm infants—A review10.1016/j.smrv.2016.03.005 ↗
15. Neonatal non-contact respiratory monitoring based on real-time infrared thermography10.1186/1475-925X-10-93 ↗
16. Koolen, N., Decroupet, O., Dereymaeker, A., Jansen, K., Vervisch, J., Matic, V., Vanrumste, B., Naulaers, G., Van Huffel, S., and De Vos, M. (2015, January 10–12). Automated Respiration Detection from Neonatal Video Data. Proceedings of the International Conference on Pattern Recognition Applications and Methods ICPRAM, Lisbon, Portugal.10.5220/0005187901640169 ↗
17. Antognoli, L., Marchionni, P., Nobile, S., Carnielli, V., and Scalise, L. (2018, January 11–13). Assessment of cardio-respiratory rates by non-invasive measurement methods in hospitalized preterm neonates. Proceedings of the 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Rome, Italy.10.1109/MeMeA.2018.8438772 ↗
18. Barron, J.L., Fleet, D.J., Beauchemin, S.S., and Burkitt, T. (1992, January 15–18). Performance of optical flow techniques. Proceedings of the 1992 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, Champaign, IL, USA.
19. Weinzaepfel, P., Revaud, J., Harchaoui, Z., and Schmid, C. (2013, January 1–8). DeepFlow: Large Displacement Optical Flow with Deep Matching. Proceedings of the IEEE International Conference on Computer Vision, Sydney, Australia.10.1109/ICCV.2013.175 ↗
20. Large Displacement Optical Flow: Descriptor Matching in Variational Motion Estimation10.1109/TPAMI.2010.143 ↗
21. LIII. On lines and planes of closest fit to systems of points in space10.1080/14786440109462720 ↗
22. Statistical methods for assessing agreement between two methods of clinical measurement10.1016/S0140-6736(86)90837-8 ↗
23. Klein, R. (2015, September 11). Bland-Altman and Correlation Plot. Available online: http://www.mathworks.com/matlabcentral/fileexchange/45049-bland-altman-and-correlation-plot.
24. Van Luijtelaar, R., Wang, W., Stuijk, S., and de Haan, G. (2014, January 1–2). Automatic roi detection for camera-based pulse-rate measurement. Proceedings of the Asian Conference on Computer Vision, Singapore.
25. Robust heart rate from fitness videos10.1088/1361-6579/aa6d02 ↗
26. Sun, Y., Kommers, D., Wang, W., Joshi, R., Shan, C., Tan, T., Aarts, R.M., van Pul, C., Andriessen, P., and de With, P.H. (2019, January 23–27). Automatic and continuous discomfort detection for premature infants in a NICU using video-based motion analysis. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.10.1109/EMBC.2019.8857597 ↗
27. Video-based discomfort detection for infants10.1007/s00138-018-0968-1 ↗
28. Sun, Y., Shan, C., Tan, T., Tong, T., Wang, W., Pourtaherian, A., and de With, P.H.N. (2019). Detecting discomfort in infants through facial expressions. Physiol. Meas.10.1088/1361-6579/ab55b3 ↗
29. Wu, Y., and Huang, T.S. (1999, January 17–19). Vision-based gesture recognition: A review. Proceedings of the International Gesture Workshop, Gif-sur-Yvette, France.