Hypertension Detection Based on Photoplethysmography Signal Morphology and Machine Learning Techniques

Lucian Evdochim, Dragoș Dobrescu, Stela Halichidis, Lidia Dobrescu, Silviu Stanciu

Applied Sciences· Volume 12· Issue 16

Abstract

In our modern digitalized world, hypertension detection represents a key feature that enables self-monitoring of cardiovascular parameters, using a wide range of smart devices. Heart rate and blood oxygen saturation rate are some of the most important ones, easily computed by wearable products that are provided by the photoplethysmography (PPG) technique. Therefore, this low-cost technology has opened a new horizon for health monitoring in the last decade. Another important parameter is blood pressure, a major predictor for cardiovascular characterization and health related events. Analyzing only PPG signal morphology and combining the medical observation with machine learning (ML) techniques, this paper develops a hypertension diagnosis tool, named the ANC Test™. During the development process, distinguishable characteristics have been observed among certain waveforms and certain types of patients that leads to an increased confidence level of the algorithm. The test was enchanted by machine learning models to improve blood pressure class detection between systolic normotensive and hypertensive patients. A total of 359 individual recordings were manually selected to build reference signals using open-source available databases. During the development and testing phases, different ML models accuracy of detecting systolic hypertension scored in many cases around 70% with a maximum value of 72.9%. This was resulted from original waveform classification into four main classes with an easy-to-understand nomenclature. An important limitation during the recording processing phase was given by a different PPG acquisition standard among the consulted free available databases.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Heart Rate Variability and Autonomic Control · Blood Pressure and Hypertension Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electronic Devices, Circuits and Architectures, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 060042 București, Romania

Department of Clinical Medical Disciplines, Faculty of Medicine, Ovidius University of Constanta, 900527 Constanța, Romania

Laboratory of Cardiovascular Noninvasive Investigations, Dr. Carol Davila Central Military Emergency University Hospital, 010242 Bucharest, Romania

Funding

University Politehnica of Bucharest

References (22)

Show source-provided references
1. Digital health: New approaches in hypertension management10.29245/2578-3025/2020/1.1186 ↗
2. Johnson, M.S.S., and Eklund, J.M. (2020, January 20–24). A Review of Photoplethysmography-based Physiological Measurement and Estimation, Part 2: Multi-input Methods. Proceedings of the 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Montreal, QC, Canada.10.1109/EMBC44109.2020.9175827 ↗
3. Evdochim, L., Dobrescu, D., Dobrescu, L., and Halichidis, S. (2019, January 21–23). Transmural pressure evaluation from blood volume optical analysis. Proceedings of the E-Health and Bioengineering Conference (EHB), Iasi, Romania.10.1109/EHB47216.2019.8969929 ↗
4. Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: An observational study10.1007/s10877-018-0235-z ↗
5. The peripheral pulse wave: Information overlooked10.1007/BF02077634 ↗
6. Broader applications of arterial pressure wave form analysis10.1093/bjaceaccp/mkt078 ↗
7. Excessive Respiratory Modulation of Blood Pressure Triggers Hypertension10.1016/j.cmet.2017.01.019 ↗
8. Photoplethysmographic assessment of pulse wave reflection: Blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus10.1016/S0735-1097(99)00441-6 ↗
9. Liang, Y., Chen, Z., Liu, G., and Elgendi, M. (2018). A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China. Sci. Data, 5.10.1038/sdata.2018.20 ↗
10. Stanley PhysioBank, PhysioToolkit, and PhysioNet. Components of a new research resource for complex physiologic signals10.1161/01.CIR.101.23.e215 ↗
11. Karlen, W., Turner, M., Cooke, E., and Dumont, G. (2010, January 13–16). CapnoBase: Signal database and tools to collect, share and annotate respiratory signals. Proceedings of the Annual Meeting of the Society for Technology in Anesthesia (STA), Florida, FL, USA.
12. University of Queensland Vital Signs Dataset10.1213/ANE.0b013e318241f7c0 ↗
13. Advanced Uses of Pulse Oximetry for Monitoring Mechanically Ventilated Patients10.1213/ANE.0000000000001283 ↗
14. Evdochim, L., Zhdanov, A.E., Dobrescu, L., and Dobrescu, D. (2022, January 16–17). Data analytics of BP-PPG dataset: Noninvasive blood pressure assessment by using photoplethysmography fiducial points. Proceedings of the 2022 International Conference on Business Analytics for Technology and Security, ICBATS 2022 (2022 International Conference on Business Analytics for Technology and Security, ICBATS 2022), Dubai, United Arab Emirates.10.1109/ICBATS54253.2022.9759027 ↗
15. Calamanti, C., Moccia, S., Migliorelli, L., Paolanti, M., and Frontoni, E. (2019). Learning-based screening of endothelial dysfunction from photoplethysmographic signals. Electronics, 8.10.3390/electronics8030271 ↗
16. The effect of local cold and warm exposure on index finger photoplethysmographic signal waveform
17. A unified mechanism for the water hammer pulse and pulsus bisferiens in severe aortic regurgitation: Insights from wave intensity analysis10.1016/j.artres.2017.12.002 ↗
18. Increased arterial stiffness in patients with chronic obstructive pulmonary disease: A mechanism for increased cardiovascular risk10.1136/thx.2007.083493 ↗
19. Role of nebivolol in the control and management of central aortic blood pressure in hypertensive patients10.1038/jhh.2017.26 ↗
20. The collapsing pulse10.12968/hmed.2012.73.Sup5.C78 ↗
21. Vlachopoulos, C., and O’Rourke, M. (2011). ; Nichols. W.W. McDonald’s Blood Flow in Arteries -Theoretical, Experimental and Clinical Principles, CRC Press.10.1201/b13568 ↗
22. Salvi, P. (2012). Pulse Waves: How Vascular Hemodynamics Affects Blood Pressure. Springer Milano. eBook.10.1007/978-88-470-2439-7_3 ↗