journal article·2020-02-06Open access

Temperature Impact on the Assessment of Reinforcement Corrosion Risk in Concrete by Galvanostatic Pulse Method

Wioletta Raczkiewicz, Artur Wójcicki

Applied Sciences· Volume 10· Issue 3

Abstract

The electrochemical galvanostatic pulse method (GPM) is used for the evaluation of the degree of corrosion risk of reinforcement in concrete. This non-destructive method enables determining the corrosion promoting conditions through the measurements of reinforcement stationary potential and concrete cover resistivity, and determining the probability of reinforcement corrosion in the tested areas. This method also allows for the estimation of the reinforcement corrosion activity and the prediction of the development of the corrosion process on the basis of corrosion current density measurements. The ambient temperature (and the temperature of the examined element) can significantly affect the values of the measured parameters due to electrochemical character of the processes as well as specific measurement technique. Differences in the obtained results can lead to a wrong interpretation of reinforcement corrosion risk degree in concrete. The article attempts to assess the effect of temperature on the measured parameters while using the galvanostatic pulse method. The GP-5000 GalvaPulseTM set was used. The results of this study confirmed the impact of temperature changes on the values of three measured parameters (reinforcement stationary potential, concrete cover resistivity, and corrosion current density) and contributed to catching the trend of these changes.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Non-Destructive Testing Techniques · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Kielce University of Technology, Faculty of Civil Engineering and Architecture, Al. Tysiąclecia Państwa Polskiego 7, 25-314 Kielce, Poland

Funding

This research was funded by grant number 02.0.06.00/2.01.01.01. 0007; MNSP. BKWB. 16.001 “Analysis of limit states, durability and diagnostics of structures and methods and tools for quality assurance in construction” [Kielce University of Technology, Kie

References (32)

Show source-provided references
1. (2008). EN 1992-1-1:2008 Eurocode 2. Design of Concrete Structures. Part 1-1: General Standard and Standards for Buildings, Polish Committee for Standardization.
2. Neville, A.M. (2011). Properties of Concrete, Pearson. [5th ed.].
3. Recent durability studies on concrete structure10.1016/j.cemconres.2015.05.021 ↗
4. Baltazar-Zamora, M.A., Bastidas, D., Santiago-Hurtado, G., Mendoza-Rangel, J.M., Gaona-Tiburcio, C., Bastidas, J.M., and Almeraya-Calderón, F. (2019). Effect of Silica Fume and Fly Ash Admixtures on the Corrosion Behavior of AISI 304 Embedded in Concrete Exposed in 3.5% NaCl Solution. Materials, 12.10.3390/ma12234007 ↗
5. Durability of Concrete Structures10.1007/s13369-010-0033-5 ↗
6. Drobiec, Ł., Jasiński, R., and Piekarczyk, A. (2010). Diagnosis of Reinforced Concrete Structures. Methodology, Field and Laboratory Testing of Concrete and Steel, PWN. [1st ed.].
7. Luo, D., Li, Y., Li, J., Lim, K.S., Nazal, N.A.M., and Ahmad, H. (2018). A Recent Progress of Steel Bar Corrosion Diagnostic Techniques in RC Structures. Sensors, 19.10.3390/s19010034 ↗
8. Measurements on corrosion rate of reinforcing steel under various environmental conditions, using an insulator to delimit the polarized area10.1016/j.proeng.2017.06.234 ↗
9. Verma, S.K., Bhadauria, S.S., and Akhtar, S. (2014). Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures. Sci. World J., 2014.10.1155/2014/957904 ↗
10. Raczkiewicz, W., and Kossakowski, P.G. (2019). Electrochemical Diagnostics of Sprayed Fiber-Reinforced Concrete Corrosion. Appl. Sci., 9.10.3390/app9183763 ↗
11. Schabowicz, K. (2019). Non-destructive testing of materials in civil engineering. Materials, 12.10.3390/ma12193237 ↗
12. State-of-the-art non-destructive methods for diagnostic testing of building structures—anticipated development trends10.1016/S1644-9665(12)60133-2 ↗
13. Stankiewicz, H. (1973). Corrosion Protection Technique. Sec. XI: Corrosion and Resistance of Mineral Materials, PWSZ.
14. Kurdowski, W. (2014). Cement and Concrete Chemistry. Industrial Chemistry and Chemical Engineering, Springer.10.1007/978-94-007-7945-7 ↗
15. Bertolini, L., Elsener, B., Pedeferri, P., and Polder, R. (2004). Corrosion of Steel in Concrete, Wiley VCH. [2nd ed.].10.1002/3527603379 ↗
16. Chess, P., and Green, W. (2019). Durability of Reinforced Concrete Structures, CRC Press. [1st ed.].
17. Corrosion Determination of Reinforcement Using The Electrical Resistance Method
18. Using non-destructive methods for measurement of reinforcement corrosion in practice
19. Corrosion of reinforcing steel evaluated by means of concrete resistivity measurements10.1016/S0010-938X(01)00033-6 ↗
20. Østvik, J.-M. (2005). Thermal Aspects of Corrosion of Steel in Concrete: Effect of Low Temperature on the Resistivity and the Cathodic Reaction Rate. [Ph.D. Thesis, Norwegian University of Science and Technology].
21. Raczkiewicz, W., Wójcicki, A., Grzmil, W., and Zapala-Slaweta, J. Impact of Environment Conditions on the Degradation Process of Selected Reinforced Concrete Elements. Proceedings of the 3rd World Multidisciplinary Civil Engineering, Architecture, Urban Planning Symposium (WMCAUS 2018), Prague, Czech RepublicPrague, Czech Republic, 18–22 June 2018, IOP Conference Serie—Materials Science and Engineering.
22. Bäßler, R., Burkert, A., Frølund, T., and Klinghofer, O. (2003). Usage of GPM-Portable equipment for determination of corrosion stage of concrete structures. Corrosion, 03388.
23. Frølund, T., Jensen, F.M., and Bäßler, R. (2002). Smart Structures: Determination of Reinforcement Corrosion Rate by Means of the GPT, IABMAS Congress.
24. Sørense, H.E., and Frølund, T. (, January October). Monitoring of reinforcement corrosion in marine concrete structures by the GPM. Proceedings of the International Conference on Concrete in Marin Environments, Hanoi, Vietnam.
25. Selected aspects of forecasting the level of reinforcing steel corrosion in concrete by electrochemical method
26. Elsener, B., Klinghoffer, O., Frolund, T., Rislund, E., Schiegg, Y., and Böhni, H. (1997, January 28–30). Assessment of reinforcement corrosion by means of galvanostatic pulse technique. Proceedings of the International Conference—Repair of Concrete Structures, Svolvaer, Norway.
27. Frølund, T., Klinghofer, O., and Poulsen, E. (2000). Rebar Corrosion Rate Measurements for Service Life Estimates, ACI Fall Convention.
28. Raczkiewicz, W., and Wójcicki, A. (2017, January 24–26). Evaluation of effectiveness of concrete coat as a steel bars protection in the structure—galvanostatic pulse method. Proceedings of the 26th International Conference On Metallurgy And Materials (METAL), Brno, Czech Republic.
29. Assessment of the impact of cement type on the process of concrete carbonation and reinforcement corrosion in reinforced concrete specimens
30. Reliability of Galvanostatic Pulse Technique in assessing the corrosion rate of rebar in concrete structures: Laboratory vs field studies10.1007/s12205-010-1023-6 ↗
31. Corrosion performance of reinforced concrete member along Indian coasts: Effect of temperature & relative humidity
32. (2019, September 28). Available online: http://www.germann.org/TestSystems/GalvaPulse/GalvaPulse.pdf.