journal article·2020-03-11Open access

Shared Tuned Mass Dampers for Mitigation of Seismic Pounding

Rajesh Rupakhety, Said Elias, Simon Olafsson

Applied Sciences· Volume 10· Issue 6

Abstract

This study explores the effectiveness of shared tuned mass damper (STMD) in reducing seismic pounding of adjacent buildings. The dynamics of STMDs is explored through numerical simulations of buildings idealized as single and multiple degree of freedom oscillators. An optimization method proposed in the literature is revisited. It is shown that the optimization results in two different solutions. The first one corresponds to the device being tuned to one of the buildings it is attached to. The second solution corresponds to a very stiff system where the TMD mass hardly moves. This solution, which has been described as an STMD in the literature, is shown to be impractical due to its high stiffness and use of a heavy stationary mass that plays no role in response mitigation but adds unnecessary load to the structure. Furthermore, it is shown that the second solution is equivalent to a viscous coupling of the two buildings. As for the properly tuned solution, i.e., the first solution, sharing the device with an adjacent building was found to provide no added benefits compared to when it is placed on one of the buildings. Based on results from a large set of real earthquake ground motions, it is shown that sharing a TMD mass with an adjacent building, in contrary to what is reported in the literature, is not an effective strategy.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Vibration Control and Rheological Fluids · Seismic Performance and Analysis · Structural Engineering and Vibration Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Earthquake Engineering Research Centre, Faculty of Civil and Environmental Engineering, School of Engineering and Natural Sciences, University of Iceland, Austurvegur 2a, 800 Selfoss, Iceland

References (34)

Show source-provided references
1. Mitigation measures for earthquake induced pounding effects on seismic performance of adjacent buildings10.1007/s10518-014-9592-2 ↗
2. Seismic pounding between adjacent buildings: Identification of parameters, soil interaction issues and mitigation measures10.1016/j.soildyn.2019.02.024 ↗
3. Numerical simulation of potential seismic pounding among adjacent buildings in series10.1007/s10518-018-0455-0 ↗
4. Dimensional analysis of the earthquake-induced pounding between adjacent structures10.1002/eqe.872 ↗
5. Use of collision shear walls to minimize seismic separation and to protect adjacent buildings from collapse due to earthquake-induced pounding10.1002/eqe.817 ↗
6. Performance of seismic-isolated bridges with and without elastic-gap devices in near-fault zones10.1002/eqe.797 ↗
7. Linking of adjacent three-storey buildings for mitigation of structural pounding during earthquakes10.1007/s10518-016-9946-z ↗
8. Closed-form equations for coupling linear structures using stiffness and damping elements10.1002/stc.490 ↗
9. Closed-form design equations for controlling vibrations in connected structures10.1080/13632469.2013.771590 ↗
10. Seismic response of dynamically similar adjacent structures connected with viscous dampers10.1080/19373260903236833 ↗
11. Dynamic response of identical adjacent structures connected by viscous damper10.1002/stc.1566 ↗
12. A probabilistic performance-based risk assessment approach for seismic pounding with efficient application to linear systems10.1016/j.strusafe.2012.01.002 ↗
13. Analysis and mitigation of seismic pounding of a slender R/C bell tower10.1016/j.engstruct.2014.04.006 ↗
14. Damped interconnection-based mitigation of seismic pounding between adjacent R/C buildings10.7763/IJET.2013.V5.585 ↗
15. Reduction of pounding between buildings using fuzzy controller
16. Optimal design of semi active control for adjacent buildings connected by MR damper based on integrated fuzzy logic and multi-objective genetic algorithm10.1016/j.engstruct.2014.03.006 ↗
17. Tuned tandem mass dampers-Inerters with broadband high effectiveness for structures under white noise base excitations10.1002/stc.2319 ↗
18. Research developments in vibration control of structures using passive tuned mass dampers10.1016/j.arcontrol.2017.09.015 ↗
19. An investigation of earthquake induced pounding between adjacent buildings10.1002/eqe.4290210402 ↗
20. Earthquake-resilient design of base isolated buildings with TMD at basement: Application to a case study10.1016/j.soildyn.2018.06.022 ↗
21. Stanikzai, M.H., Elias, S., Matsagar, V.A., and Jain, A.K. (2019). Seismic response control of base-isolated buildings using tuned mass damper. Aust. J. Struct. Eng., 1–2.10.1080/13287982.2019.1635307 ↗
22. Seismic Response Control of Base-Isolated Buildings Using Multiple Tuned Mass Dampers10.1002/tal.1576 ↗
23. Stanikzai, M.H., Elias, S., and Rupakhety, R. (2020). Seismic Response Mitigation of Base-Isolated Buildings. Appl. Sci., 10.10.3390/app10041230 ↗
24. An enhanced base isolation system equipped with optimal tuned mass damper inerter (TMDI)10.1002/eqe.3011 ↗
25. Innovative base-isolated building with large mass-ratio TMD at basement for greater earthquake resilience10.1186/s40984-015-0007-6 ↗
26. Optimal design and seismic performance of tuned fluid inerter applied to structures with friction pendulum isolators10.1016/j.soildyn.2020.106099 ↗
27. Effective base isolation combining low-friction curved surface sliders and hysteretic gap dampers10.1016/j.soildyn.2019.105989 ↗
28. Use of a shared tuned mass damper (STMD) to reduce vibration and pounding in adjacent structures10.1002/eqe.58 ↗
29. Seismic response control of adjacent buildings coupled by semi-active shared TMD10.1007/s13296-016-6030-0 ↗
30. A method of estimating the parameters of tuned mass dampers for seismic applications10.1002/(SICI)1096-9845(199706)26:6<617::AID-EQE664>3.0.CO;2-Z ↗
31. Internet site for European strong-motion data
32. Rotation-invariant measures of earthquake response spectra10.1007/s10518-013-9472-1 ↗
33. Rotation-invariant mean duration of strong ground motion10.1007/s10518-013-9521-9 ↗
34. Ambraseys, N.N., Douglas, J., Sigbjörnsson, R., Berge-Thierry, C., Suhadolc, P., Costa, G., and Smit, P.M. (2004, January 1–6). Dissemination of European strong-motion data, Volume 2. Proceedings of the 13th World Conference on Earthquake Engineering, Vancouver, CO, Canada.