journal article·2020-10-23Open access

Noise Level and Similarity Analysis for Computed Tomographic Thoracic Image with Fast Non-Local Means Denoising Algorithm

Bae-Guen Kim, Seong-Hyeon Kang, Chan Rok Park, Hyun-Woo Jeong, Youngjin Lee

Applied Sciences· Volume 10· Issue 21

Abstract

Although conventional denoising filters have been developed for noise reduction from digital images, these filters simultaneously cause blurring in the images. To address this problem, we proposed the fast non-local means (FNLM) denoising algorithm which would preserve the edge information of objects better than conventional denoising filters. In this study, we obtained thoracic computed tomography (CT) images from a male adult mesh (MASH) phantom modeled by computer and a five-year-old phantom to perform both the simulation study and the practical study. Subsequently, the FNLM denoising algorithm and conventional denoising filters, such as the Gaussian, median, and Wiener filters, were applied to the MASH phantom image adding Gaussian noise with a standard deviation of 0.002 and practical CT images. Finally, the results were compared quantitatively in terms of the coefficient of variation (COV), contrast-to-noise ratio (CNR), peak signal-to-noise ratio (PSNR), and correlation coefficient (CC). The results showed that the FNLM denoising algorithm was more efficient than the conventional denoising filters. In conclusion, through the simulation study and the practical study, this study demonstrated the feasibility of the FNLM denoising algorithm for noise reduction from thoracic CT images.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Medical Imaging Techniques and Applications · Image and Signal Denoising Methods · Radiation Dose and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Radiological Science, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon 21936, Korea

Department of Radiological Science, Jeonju University, 303, Cheonjam-ro, Wansan-gu, Jeonju-si 55069, Korea

Department of Biomedical Engineering, Eulji University, 553, Sanseong-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13135, Korea

Funding

Ministry of SMEs and Startups

References (36)

Show source-provided references
1. Managing Radiation Use in Medical Imaging: A Multifaceted Challenge10.1148/radiol.10101157 ↗
2. Evaluation of effective dose and entrance skin dose in digital radiology10.2478/pjmpe-2020-0013 ↗
3. Dose and perceived image quality in chest radiography10.1016/j.ejrad.2009.05.039 ↗
4. Dosimetric Characterization and Image Quality Assessment in Breast Tomosynthesis10.1109/TIM.2017.2692318 ↗
5. The National Lung Screening Trial Research Team (2011). Reduced lung-cancer mortality with low dose computed tomographic screening. N. Engl. J. Med., 365, 395–407.10.1056/NEJMoa1102873 ↗
6. Dose Optimization in Chest Radiography: System and Model Characterization via Experimental Investigation10.1109/TIM.2013.2282411 ↗
7. CT scanning: Patterns of use and dose10.1088/0952-4746/20/4/301 ↗
8. Low-dose CT of the lungs: Preliminary observations10.1148/radiology.175.3.2343122 ↗
9. CT Radiation Dose Optimization and Estimation: An Update for Radiologists10.3348/kjr.2012.13.1.1 ↗
10. New hybrid filtering techniques for removal of Gaussian noise from medical images
11. Performance Comparison of Median and Wiener Filter in Image De-noising
12. Buades, A., Coll, B., and Morel, J.-M. (2005, January 20–25). A Non-Local Algorithm for Image Denoising. Proceedings of the 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR’05), San Diego, CA, USA.
13. SNR enhancement of highly-accelerated real-time cardiac MRI acquisitions based on non-local means algorithm10.1016/j.media.2009.05.006 ↗
14. Noise reduction in medical mammography images using fast nonlocal means denoising algorithm for early breast cancer detection10.1016/j.ijleo.2018.11.167 ↗
15. A study for feasibility of fast non-local means (FNLM) noise reduction algorithm in MRI image with diffusion weighted image (DWI) technique10.1016/j.ijleo.2019.02.036 ↗
16. Coupé, P., Yger, P., and Barillot, C. (2006, January 1–6). Fast Non Local Means Denoising for 3D MR Images. Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, Copenhagen, Denmark.10.1007/11866763_5 ↗
17. Dauwe, A., Goossens, B., Luong, H.Q., and Philips, W. (2008, January 27–31). A fast non-local image denoising algorithm. Proceedings of the Electronic Imaging, San Jose, CA, USA.10.1117/12.765505 ↗
18. Feasibility of newly designed fast non local means (FNLM)-based noise reduction filter for X-ray imaging: A simulation study10.1016/j.ijleo.2018.01.101 ↗
19. Conversion of ICRP male reference phantom to polygon-surface phantom10.1088/0031-9155/58/19/6985 ↗
20. FASH and MASH: Female and male adult human phantoms based on polygon mesh surfaces: II. Dosimetric calculations10.1088/0031-9155/55/1/010 ↗
21. FASH and MASH: Female and male adult human phantoms based on polygon mesh surfaces: I. Development of the anatomy10.1088/0031-9155/55/1/009 ↗
22. Huang, K., Zhang, D., and Wang, K. (November, January 30). Non-local means denoising algorithm accelerated by GPU. Proceedings of the Sixth International Symposium on Multispectral Image Processing and Pattern Recognition, Yichang, China.
23. Inferences on the common coefficient of variation10.1002/sim.2088 ↗
24. X-ray scattering in single- and dual-source CT10.1118/1.2820901 ↗
25. Alain, H., and Djemel, Z. (2010, January 23–26). Image quality metrics: PSNR vs. SSIM. Proceedings of the 20th International Conference on Pattern Recognition, Istanbul, Turkey.
26. Statistics Corner: A Guide to Appropriate Use of Correlation Coefficient in Medical Research
27. Computed tomographic image comparison between mediastinal and lung windows provides possible prognostic information in patients with small peripheral lung adenocarcinoma10.1067/mtc.2002.125647 ↗
28. Muhammad, M.N., Varutbangkul, E., Raicu, D.S., and Furst, J.D. (2008, January 16–21). Texture versus shape analysis for lung nodule similarity in computed tomography studies. Proceedings of the Medical Imaging, San Diego, CA, USA.10.1117/12.771009 ↗
29. Similarities in the Computed Tomography Appearance in α1-Antitrypsin Deficiency and Smoking-Related Chronic Obstructive Pulmonary Disease in a Smoking Collective10.1159/000489177 ↗
30. Lee, S., Lee, M.S., and Kang, M.G. (2018). Poisson–Gaussian Noise Analysis and Estimation for Low-Dose X-ray Images in the NSCT Domain. Sensors, 18.10.3390/s18041019 ↗
31. A method to extract image noise level from patient images in CT10.1002/mp.12240 ↗
32. Density and atomic number measurements with spectral X-ray attenuation method10.1063/1.1586963 ↗
33. Correlation of Effective Atomic Number and Electron Density with Attenuation Coefficients Measured with Polychromatic X Rays10.1148/117.3.585 ↗
34. Lin, Z., and Song, E. (2017, January 28–29). A fast non-local means algorithm based on integral image and reconstructed similar kernel. Proceedings of the Tenth International Symposium on Multispectral Image Processing and Pattern Recognition (MIPPR2017), Xiangyang, China.10.1117/12.2288315 ↗
35. A Robust and Fast Non-Local Means Algorithm for Image Denoising10.1007/s11390-008-9129-8 ↗
36. Iterative Reconstruction in Head CT: Image Quality of Routine and Low-Dose Protocols in Comparison with Standard Filtered Back-Projection10.3174/ajnr.A2749 ↗