journal article·2021-01-29Open access

Variational Mode Decomposition Based Time-Varying Force Identification of Stay Cables

Shitong Hou, Bin Dong, Jianhua Fan, Gang Wu, Haochen Wang, Yitian Han, Xiaojin Zhao

Applied Sciences· Volume 11· Issue 3

Abstract

Stay cables are important structural members of cable-stayed bridges, which play a significant role in the health monitoring and assessment of cable-stayed bridges. The in-service cable force, which varies from the effects of vehicle load, wind load and other environmental factors, may cause fatigue damage in stay cables. Traditional force identification methods can only calculate the time-average cable force instead of the instantaneous force. A novel method has been proposed in this paper for identifying time-varying cable tension based on the variational mode decomposition (VMD) method. This recent method decomposes signals and adaptively estimates instantaneous frequency combined with the Hilbert–Huang transform method. In the proposed study, the time-varying modal frequencies were identified from stay cable acceleration data, and then the time-varying cable tension was identified by the relationship between cable tension and identified fundamental frequency. Scaled and full-scale models of stay cables were implemented successively to illustrate the validity of the proposed method. The results showed that the variational mode decomposition (VMD) method has a good effect on identifying the time-varying cable forces, even the sudden changes in cable force. According to the cable force identification results, the maximum error was 8.4%, which meets the actual application of time-varying cable force measurements. An on-site test was also implemented to monitor the cable force during a construction period, and the results showed that the proposed method can provide accurate real-time results for evaluation and decision-making.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Health Monitoring Techniques · Machine Fault Diagnosis Techniques · Mechanical stress and fatigue analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Key Laboratory of Concrete and Prestressed Concrete Structures of the Ministry of Education, Southeast University, Nanjing 210096, China

National and Local Joint Engineering Research Center for Intelligent Construction and Maintenance, Southeast University, Nanjing 210096, China

Key Laboratory of Road Construction and Maintenance Technology and Transportation Industry in Loess Area, Shanxi Communications Technology R&D Co. Ltd., Taiyuan 030027, China

Funding

National Natural Science Foundation of China

References (30)

Show source-provided references
1. Empirical formulas to estimate cable tension by cable fundamental frequency10.12989/sem.2005.20.3.363 ↗
2. Real time cable force identification by short time sparse time domain algorithm with half wave10.1016/j.measurement.2019.107355 ↗
3. Real-time dynamic displacement monitoring with double integration of acceleration based on recursive least squares method10.1016/j.measurement.2019.04.053 ↗
4. Cable tension force estimate using novel noncontact vision-based sensor10.1016/j.measurement.2016.12.020 ↗
5. Dynamic measurement of stay-cable force using digital image techniques10.1016/j.measurement.2019.107211 ↗
6. Feng, Z., Wang, X., and Chen, Z. (2010). A method of fundamental frequency hybrid recognition for cable tension measurement of cable-stayed bridges. IEEE Int. Conf. Robot. Autom., 75–79.10.1109/ICCA.2010.5524186 ↗
7. Cable Tension Measurement of Cable Stayed Bridge Based on Frequency Method10.4028/www.scientific.net/AMM.405-408.1587 ↗
8. Wang, M., Satpathi, D., Koontz, S., Jarosevic, A., and Chandoga, M. (1999). Monitoring of cable forces using magneto-elastic sensors. Computational Mechanics in Structural Engineering, Elsevier.10.1016/B978-008043008-9/50064-8 ↗
9. Zhang, R., Duan, Y., Zhao, Y., and He, X. (2018). Temperature Compensation of Elasto-Magneto-Electric (EME) Sensors in Cable Force Monitoring Using BP Neural Network. Sensors, 18.10.3390/s18072176 ↗
10. Deflection measurement on vibrating stay cables by non-contact microwave interferometer10.1016/j.ndteint.2009.11.007 ↗
11. Research on cable force testing method of cable-stayed bridge model test10.4028/www.scientific.net/AMM.351-352.1325 ↗
12. Determination of cable tensions based on frequency differences10.1108/02644400810855977 ↗
13. Practical formulas for estimation of cable tension by vibration method10.1061/(ASCE)0733-9445(1996)122:6(651) ↗
14. Wei, J., Li, G., and Razavi, M.R. (2008). Theoretical study on cable tension detection considering support vibration. Transp. Dev. Innov. Best Pract., 450–455.10.1061/40961(319)74 ↗
15. Monitoring based maintenance utilizing actual stress sensory technology10.1088/0964-1726/14/3/009 ↗
16. Nonlinear vibration of shallow cables with semiactive tuned mass damper10.1007/s11071-007-9298-y ↗
17. Unified practical formulas for vibration-based method of cable tension estimation10.1260/1369-4332.18.3.405 ↗
18. Tension force and structural parameter identification of bridge cables10.1260/1369-4332.15.6.983 ↗
19. Real-time identification of time-varying tension in stay cables by monitoring cable transversal acceleration10.1002/stc.1634 ↗
20. Real-time output-only identification of time-varying cable tension from accelerations via complexity pursuit10.1061/(ASCE)ST.1943-541X.0001337 ↗
21. Identification of time-varying cable tension forces based on adaptive sparse time-frequency analysis of cable vibrations10.1002/stc.1889 ↗
22. Adaptive data analysis via sparse time-frequency representation10.1142/S1793536911000647 ↗
23. Convergence of a data-driven time–frequency analysis method10.1016/j.acha.2013.12.004 ↗
24. Candès, E.J. (2006, January 22–26). Compressive sampling. Proceedings of the International Congress of Mathematicians, Madrid, Spain.
25. The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis10.1098/rspa.1998.0193 ↗
26. Variational mode decomposition10.1109/TSP.2013.2288675 ↗
27. Research on the intrinsic mode function (IMF) criterion in EMD method10.1016/j.ymssp.2005.09.011 ↗
28. A new definition of the intrinsic mode function
29. On intrinsic mode function10.1142/S1793536910000549 ↗
30. Adaptive AM–FM signal decomposition with application to speech analysis10.1109/TASL.2010.2047682 ↗