journal article·2020-05-20Open access

Development of a Lightweight Prosthetic Hand for Patients with Amputated Fingers

Wooseok Ryu, Youngjin Choi, Yong Je Choi, Sungon Lee

Applied Sciences· Volume 10· Issue 10

Abstract

Finger amputations are the most common upper limb amputation, and they occur approximately 100 times more often than hand amputations. We developed a prosthetic hand for amputees with a thumb and metacarpal. In this case of amputation, the installation of actuators and electrical components is difficult because space is considerably limited owing to the residual metacarpal. This design issue is solved by installing actuators vertically between finger modules and the mounting part where the electrical parts are embedded. With this design, the arrangement between the palm of the patient and the fingers of the prosthetic hand can be adjusted as well. Weight is also an especially important design issue in the development of a practical prosthetic hand because the patient perceives that weight. Most prosthetic hands are attached to the residual limb of the amputee by compressing the contact surface between the product and the amputated body part of the patient. Heavy weight causes users to feel discomfort and fatigue over extended periods of usage. In this study, all frames used in the proposed prosthetic hand were fabricated from nylon using multi-jet-fusion three-dimensional printing. As a result, the weight of the developed prosthetic hand was only 152.32 g but still had the desired strength and stiffness. Each prosthetic finger has four-degree-of-freedom. The distal interphalangeal, proximal interphalangeal, and metacarpophalangeal joints are coupled and driven by power from an actuator, which is transferred to each joint through the tendons. Adduction, abduction, and self-adaptive grasping motions were passively realized using linear and torsional springs. The prototype was fabricated based on these design concepts and functions, and its functionality was verified in experiments using diverse objects.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Robot Manipulation and Learning · Muscle activation and electromyography studies · Prosthetics and Rehabilitation Robotics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, Yonsei University, Seoul 03722, Korea

School of Electrical and Engineering, Hanyang University, Ansan 15588, Korea

Funding

National Research Foundation of Korea

References (17)

Show source-provided references
1. Patterns in blast injuries to the hand10.1007/s11552-008-9125-z ↗
2. Functional outcomes of post-traumatic metacarpal hand reconstruction with free toe-to-hand transfer10.4103/0970-0358.182232 ↗
3. The indications for toe transfer after “minor” finger injuries10.1016/j.jhsb.2003.12.004 ↗
4. Optimal design of driving mechanism in a 1-DOF anthropomorphic finger10.1016/j.mechmachtheory.2006.03.016 ↗
5. Underactuated Finger Mechanism for Body-Powered Partial Prosthesis10.7746/jkros.2016.11.4.193 ↗
6. Kamikawa, Y., and Maeno, T. (2008, January 22–26). Underactuated Five-Finger Prosthetic Hand Inspired by Grasping Force Distribution of Humans. Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems, Acropolis Convention Center, Nice, France.10.1109/IROS.2008.4650628 ↗
7. Jing, X., Yong, X., Tian, L., Togo, S., Jiang, Y., Yokoi, H., and Li, G. (2018, January 1–5). Development of Tendon Driven Under-Actuated Mechanism Applied in an EMG Prosthetic Hand with Three Major Grasps for Daily Life. Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), Madrid, Spain.10.1109/IROS.2018.8593939 ↗
8. Mottard, A., Laliberte, T., and Gosselin, C. (2017, January 12–16). Underactuated tendon-driven robotic/prosthetic hands: Design issues. Proceedings of the Robotics: Science and Systems, Cambridge, MA, USA.10.15607/RSS.2017.XIII.019 ↗
9. RSL Steeper Website (2020, April 15). Leeds (United Kingdom): RSL Steeper; 2013. Available online: http://rslsteeper.com/.
10. Touch Bionics Website (2020, April 17). Mansfield (MA): Touch Bionics Inc.; 2013. Available online: http://www.touchbionics.com/.
11. Ryu, W., Kim, D., Choi, Y., and Lee, S. (2019, January 24–27). Development of Prosthetic Finger with Actuator. Proceedings of the 16th International Conference on Ubiquitous Robots (UR), Jeju, Korea.10.1109/URAI.2019.8768698 ↗
12. Bionic prosthetic hands: A review of present technology and future aspirations
13. Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review10.1682/JRRD.2011.10.0188 ↗
14. Fabrication of polymeric lattice structures for optimum energy absorption using Multi Jet Fusion technology10.1016/j.matdes.2018.05.059 ↗
15. Selective laser sintering and multi jet fusion: Process-induced modification of the raw materials and analyses of parts performance
16. The MANUS-HAND∗ Dextrous Robotics Upper Limb Prosthesis: Mechanical and Manipulation Aspects10.1023/B:AURO.0000016862.38337.f1 ↗
17. (2020, April 17). Anthropometry and Biomechanics, Available online: https://msis.jsc.nasa.gov/sections/section03.htm.