Compressive Strength Testing of Hybrid Concrete-Filled Fiber-Reinforced Plastic Tubes Confined by Filament Winding
Source abstract
Abstract
In this study, an experiment on compressive strength of the hybrid concrete-filled fiber-reinforced polymer (FRP) tube (CFFT) confined by filament winding was conducted to improve the longitudinal strength while considering the thickness of filament winding as a variable. A maximum error of 17% was observed when the results of performing the finite element analysis (FEA) by applying the mechanical properties of the fiber-reinforced polymer (FRP) materials suggested in previous studies were compared to those of the compressive strength experiment on the hybrid-CFFT. Moreover, a maximum error of 15% was exhibited when the results derived from the strength equation proposed by analyzing the compressive strength experiment were compared. Furthermore, the compressive strength of the hybrid-CFFT increased by up to 14% when the longitudinal compressive strength of the pre-tensioned spun high strength concrete (PHC) pile and concrete-filled tube (CFT) were compared.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Management Support Division, VNIEL CONSULTANT CO., Ltd., 909 Daeryung Technotown 12th, 14, Gasan digital 2-ro, Geumcheon-gu, Seoul 08592, Korea
Department of Architectural Engineering, Gachon University, 1342 Seongnamdaero, Sujeong-gu, Gyeonggi-do, Seongnam-si 13120, Korea
References (29)
Show source-provided references
1. Lampo, R., Noskèr, T., Barno, D., Busel, J., Maher, A., Dutta, P., and Odello, R. (1998). Development and Demonstration of FRP Composite Fender. Loadbearing and Sheet Piling System, Construction Engineering Research Lab. (Army). Technical Report.
2. The Federal Highway Administration (FHWA) (2006). A Laboratory and Field Study of Composite Piles for Bridge Substractures, The Federal Highway Administration. Report No. FHWA-HRT-04-043.
3. Verification of Applicability of Hybrid CFFT Pile for Numerical Analysis
4. Richart, F.E., Brandtzaeg, A., and Brown, R.L. (1929). The Failure of Plain and Spiral Reinforced Concrete in Compression, University of Illinois. Engineering Experiment Station Bullentin, 190.
5. Morales, S.M. (1982). Spirally-Reinforced High Strength Concrete Columns, Cornell University. Report No. 82-10.
6. Stress-Strain Characteristics of Concrete Confined in Steel Binders10.1680/macr.1970.22.72.173 ↗
7. Confinement effectiveness of circular concrete-filled steel tubular columns under axial compression10.1016/j.jcsr.2019.03.012 ↗
8. FRP jacketed concrete under uniaxial compression10.1016/0950-0618(95)00004-Y ↗
9. Stress-Strain Relationship of Concrete Cylinders Confined with FRP Composites
10. Picher, F., Rochette, P., and Labossiere, P. (1996, January 15–17). Confinement of Concrete Cylinders with CFRP. Proceedings of the first International Conference on Composites in Infrastructure, Tuscon, AZ, USA.
11. Automatic Optimal Design of Tall Steel Building Frameworks10.1061/(ASCE)0733-9445(1995)121:5(838) ↗
12. Effect of Column Parameters on Axial Compression Behavior of Concrete-Filled FRP Tubes10.1260/136943305774353098 ↗
13. Experimental investigation on axial compressive behavior of ultra-high performance concrete (UHPC) filled glass FRP tubes10.1016/j.conbuildmat.2019.07.204 ↗
14. Compressive behavior of CFFT with inner steel wire mesh10.1016/j.compstruct.2015.07.075 ↗
15. Richart, F.E., Brandtzaeg, A., and Brown, R.L. (1928). A Study of the Failure of Concrete under Combined Compressive Stresses, University of Illinois. Engineering Experiment Station Bull, 185.
16. Composite Jacketed Concrete under Uniaxial Compression—Verification of Simple Design Equations10.1061/(ASCE)0899-1561(1997)9:4(185) ↗
17. Samaan, M. (1998). Analytical and Experimental Investigation of FRP Concrete Composite Columns. [Ph.D. Thesis, University of Central Florida].
18. Strengthening Effects of Concrete Columns with Carbon Fiber Sheet
19. Behavior of Concrete Columns Confined with Fiber Reinforced Polymer Tubes
20. Design-Oriented Stress-Strain Model for FRP-Confined Concrete10.1016/S0950-0618(03)00045-X ↗
21. An, D.J. (2011). Structural Characteristics of Hybrid FRP-Concrete Composite Pile. [Ph.D. Thesis, Hongik University].
22. ASTM D3039/3039M (2017). Standard Test Method for Tensile Properties of Polymer Matrix Composite Materials, ASTM International. ASTM International D3039/3039M-17.
23. ASTM D2290 (2019). Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe, ASTM International. ASTM International D2290-19a.
24. KS F 2405 (2017). Standard Test Method for Compressive Strength of Concrete, Korean Standards Association.
25. ANSYS (2008). Release 11.0 Documentation for ANSYS, ANSYS.
26. An Experimental Study for the Compression Strength of Hybrid CFFT Pile10.11004/kosacs.2011.2.1.030 ↗
27. Compression Strength Test of FRP Reinforced Concrete Composite Pile10.11004/kosacs.2011.2.4.019 ↗
28. Choi, Y., Kim, D.C., Kim, S.S., and Nam, M.S. (2009, January 25). Development and Test Construction Plan of a Noise & Vibration-Free PHC Screw Pile. Proceedings of the 2009 Workshop of Korea Geotechnical Society of Foundation Technical Committee, Seoul, Korea.
29. (2010). Evaluation of the Residual Strength of Square CFT Columns After a Fire Through Structural Performance Evaluation Test. Urban Habitat Constructions under Catastrophic Events, Proceedings of the Final Conference, Naples, Italy, 16–18 September 2010, Taylor & Francis Group.