journal article·2022-08-31Open access

Investigation of Behavior of Masonry Walls Constructed with Autoclaved Aerated Concrete Blocks under Blast Loading

Somayeh Mollaei, Reza Babaei Ghazijahani, Ehsan Noroozinejad Farsangi, Davoud Jahani

Applied Sciences· Volume 12· Issue 17

Abstract

Autoclaved aerated concrete (AAC) blocks have widespread popularity in the construction industry. In addition to lightness, these materials have other advantages, including fire resistance, low acoustic and thermal conductivity, ease of cutting and grooving, and simple transportation. Since the behavior of AAC under severe dynamic loading conditions such as blast loads has not been adequately studied in the literature, in the current paper, the behavior of masonry walls constructed with AAC blocks was evaluated under blast loading. In this study, after performing experimental testing on materials and obtaining their compressive, tensile, and shear strength values, the finite element (FE) models of AAC-based masonry walls were created in the ABAQUS/Explicit nonlinear platform. Three different wall thicknesses of 15, 20, and 25 cm were simulated, and the models were analyzed under a lateral explosion caused by 5 and 7 kg of TNT at the stand-off distances of 2, 5, and 10 m from the wall face. The stress distributions, displacement responses, adsorbed energy, and crack propagation pattern were investigated in each case. The results showed the inappropriate behavior of these materials against explosion loads, especially at shorter distances and on walls with less thickness. The outcome gives valuable information to prioritize these walls for possible blast strengthening.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Response to Dynamic Loads · Masonry and Concrete Structural Analysis · Building materials and conservation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil Engineering, University of Bonab, Bonab 55513-95167, Iran

Department of Civil Engineering, University of British Columbia (UBC), Vancouver, BC V6T 1Z4, Canada

Department of Mechanical Engineering, University of Bonab, Bonab 55517-61167, Iran

References (72)

Show source-provided references
1. Heat and power characteristics analysis carried out for the residential building made of autoclaved aerated concrete blocks
2. Carbonation of autoclaved aerated concrete containing fly ash10.1002/cepa.880 ↗
3. Sustainable applications for utilization the construction waste of aerated concrete10.1016/j.jclepro.2019.04.357 ↗
4. Quantitative and Qualitatively Evaluation of New Technologies in Perspective of Construction Optimization10.11648/j.ajce.s.2015030202.23 ↗
5. Embodied energy and carbon in construction materials
6. Sherin, K., and Saurabh, J.K. (2018, January 3–4). Review of autoclaved aerated concrete: Advantages and disadvantages. Proceedings of the National Conference of Advanced Structures, Materials and Methodology in Civil Engineering-ASMMCE-2018, Punjab, India.
7. Damage evaluation of H-section steel columns under impulsive blast loads via gene expression programming10.1016/j.engstruct.2020.110909 ↗
8. Numerical damage evaluation assessment of blast loaded steel columns with similar section properties10.1016/j.istruc.2019.04.002 ↗
9. Investigation of Axial Strengthened Reinforced Concrete Columns under Lateral Blast Loading
10. Assessment of Damage and Residual Load Capacity of the Normal and Retrofitted RC Columns against the Impact Loading
11. Experimental investigations on the resistance of masonry walls with AAC thermal break layer10.1016/j.conbuildmat.2019.06.205 ↗
12. Autoclaved aerated concrete behavior under explosive action10.1016/S0950-0618(98)00020-8 ↗
13. Seismic testing of autoclaved aerated concrete shear walls: A comprehensive review
14. Design and seismic testing of two-story, full-scale autoclaved aerated concrete assemblage specimen
15. ACI Committee 523 (2009). Guide for Design and Construction with Autoclaved Aerated Concrete Panels (ACI 523.4R-09), American Concrete Institute.
16. Uddin, N., Shelar, K.V., and Fouad, F. (2006, January 18–21). Impact response of autoclave aerated concrete/FRP sandwich structures. Proceedings of the Structures Congress 2006: Structural Engineering and Public Safety, ASCE, St. Louis, MO, USA.10.1061/40889(201)214 ↗
17. Shaking table study and modelling of seismic behaviour of confined AAC masonry buildings10.1007/s10518-011-9331-x ↗
18. Analytical modeling of the high-velocity impact of autoclaved aerated concrete (AAC) blocks and some experimental results10.1016/j.ijmecsci.2019.05.043 ↗
19. U.S. Department of the Army, the Navy and Air Force (1986). Fundamental of Protective Design for Conventional Weapons-Technical Manual (TM 5-855-1), U.S. Department of the Army.
20. U.S. Department of the Army, the Navy and Air Force (1990). The Design of Structures to Resist the Effects of Accidental Explosions-Technical Manual (TM 5-1300), U.S. Department of the Army.
21. U.S. Department of Defense (DOD) (2008). Structures to Resist the Effects of Accidental Explosions (UFC 3-340-02), DOD.
22. Numerical simulation of damage of low-rise RC frame structures with infilled masonry walls to explosive loads10.1080/13287982.2006.11464960 ↗
23. Safe scaled distance for masonry infilled RC frame structures subjected to airblast loads10.1061/(ASCE)0887-3828(2007)21:6(422) ↗
24. Model validation and parametric study on the blast response of unreinforced brick masonry walls10.1016/j.ijimpeng.2010.04.003 ↗
25. Experimental study of masonry wall exposed to blast loading10.3989/mc.2014.01513 ↗
26. Numerical modelling of infilled clay brick masonry under blast loading10.1260/1369-4332.17.4.591 ↗
27. Pereira, J.M., Campos, J., and Lourenço, P.B. (2014, January 7–9). Experimental study on masonry infill walls under blast loading. Proceedings of the 9th International Masonry Conference, Guimarães, Portugal.
28. Experimental studies on the local damage and fragments of unreinforced masonry walls under close-in explosions10.1016/j.ijimpeng.2015.12.002 ↗
29. Blast resistance of tuff stone masonry walls10.1016/j.engstruct.2016.01.056 ↗
30. Experimental analysis of debris distribution of masonry panels subjected to long duration blast loading10.1016/j.engstruct.2016.10.054 ↗
31. Response of masonry systems against blast loading10.1016/j.dt.2020.07.003 ↗
32. Modeling and parameter importance investigation for simulating in-plane and out-of-plane behaviors of un-reinforced masonry walls10.1016/j.engstruct.2021.113233 ↗
33. (2011). Blast Protection of Buildings (Standard No. ASCE/SEI 59-11).
34. Stanley, M., Metzger, J., Martinez, R., and Koenig, J. (2005). UL-Like Testing of Commercial Off-the-Shelf Products That Enhance the Blast and Ballistic Resistance of Structures, Quick Look Report 2, New Mexico Tech, Energetic Materials Research and Testing Center, Karagozian & Case.
35. Blast resistance of FRP-strengthened masonry walls. I: Approximate analysis and field explosion tests10.1061/(ASCE)1090-0268(2009)13:5(422) ↗
36. Blast response of lightly attached concrete masonry unit walls10.1061/(ASCE)0733-9445(2005)131:8(1186) ↗
37. Blast response of GFRP-strengthened infill masonry walls10.1016/j.conbuildmat.2016.04.053 ↗
38. Out-of-plane behaviour of hollow concrete block masonry walls unstrengthened and strengthened with CFRP composite10.1016/j.compositesb.2014.08.006 ↗
39. Responses of masonry infill walls retrofitted with CFRP, steel wire mesh and laminated bars to blast loadings10.1260/1369-4332.17.6.817 ↗
40. Retrofitting of unreinforced masonry walls under blast loading by FRP and spray on polyurea
41. Dynamic response of retrofitted masonry walls for blast loading10.1061/(ASCE)EM.1943-7889.0000128 ↗
42. Numerical Analysis on the Behavior of Autoclaved Aerated Concrete Block Infilled Wall Subjected to Gas Explosion10.4028/www.scientific.net/AMM.723.259 ↗
43. Study of autoclaved aerated concrete masonry walls under vented gas explosions10.1016/j.engstruct.2017.03.033 ↗
44. Blast response of polymer-retrofitted masonry unit walls10.1016/j.compositesb.2016.02.044 ↗
45. Effect of high strain rate and confinement on the compressive properties of autoclaved aerated concrete10.1016/j.ijimpeng.2021.103943 ↗
46. Penetration Resistance of Building Materials against 7.62-mm Armor-Piercing Projectile10.1061/(ASCE)MT.1943-5533.0003858 ↗
47. Stepinac, M., Kisicek, T., Renić, T., Hafner, I., and Bedon, C. (2020). Methods for the Assessment of Critical Properties in Existing Masonry Structures under Seismic Loads—The ARES Project. Appl. Sci., 10.10.3390/app10051576 ↗
48. Hinman, E. (2003). Primer for Design of Commercial Buildings to Mitigate Terrorist Attacks, Federal Emergency Management Agency (FEMA).
49. Cormie, D., Mays, G., and Smith, P.D. (2009). Blast Effects on Buildings, Thomas Telford. [2nd ed.].10.1680/beob2e.35218 ↗
50. Numerical Solutions of Spherical Blast Waves10.1063/1.1722085 ↗
51. Design of blast resistant structures
52. Mills, C.A. (1987, January 27–30). The design of concrete structure to resist explosions and weapon effects. Proceedings of the 1st International Conference on Concrete for Hazard Protections, Edinburgh, UK.
53. Baker, W.E., Cox, P.A., Westine, P.S., Kulesz, J.J., and Strehlow, R.A. (1983). Explosion Hazards and Evaluation, Elsevier Scientific.
54. Hyde, D. (1988). User’s Guide for Microcomputer Programs CONWEP and FUNPRO, Applications of TM 5-855-1: Fundamentals of Protective Design for Conventional Weapons, USA Army Engineers Waterways Experimentation.
55. Masonry Standards Joint Committee (2016). Building Code Requirements and Specification for Masonry Structures: Containing Building Code Requirements for Masonry Structures (TMS 402-11/ACI 530-11/ASCE 5-11), and Specification for Masonry Structures TMS 402-11/ACI 530-11/ASCE 6-11), and Companion Commentaries, ASCE.
56. Investigation on the Stress Distribution and Flexural Strength of Structural Lightweight Aggregate Concrete
57. (2011). Abaqus v. 6.14 Documentation, Dassault Systemes Simulia Corporation.
58. Archaeological consolidation of UNESCO masonry structures in Oman: The Sumhuram Citadel of Khor Rori and the Al Balid Fortress10.1080/15583058.2012.665146 ↗
59. Discrete rotating links model for the non-linear torsion−shear behaviour of masonry joints
60. A micro-mechanical model for the homogenisation of masonry10.1016/S0020-7683(02)00230-5 ↗
61. Nonlinear static and dynamic analysis of rocking masonry corners using rigid macro-block modeling10.1142/S0219455419501372 ↗
62. The influence of mortar head joints on the in-plane and out-of-plane seismic strength of brick masonry walls
63. Modelling approaches of the in-plane shear behaviour of unreinforced and FRP strengthened masonry panels10.1016/j.compstruct.2005.04.012 ↗
64. Lourenço, P.B., and Rots, J. (1994). Analysis of Masonry Structures with Interface Elements-Report No. 03-21-22-0, Delft University of Technology.
65. Computations on historic masonry structures10.1002/pse.120 ↗
66. The modified compression-field theory for reinforced concrete elements subjected to shear
67. Korany, Y., and EL-Haggar, S. (2003, January 7–18). Mechanics and modeling of URM structures. Proceedings of the International Short Course on Architectural and Structural Design of Masonry, Dresden, Germany.
68. (2002). Standard Test Method for Compressive Strength of Lightweight Insulating Concrete (Standard No. ASTM C495).
69. (1999). Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube Specimens) (Standard No. ASTM, C109).
70. (2012). Standard Test Method for Tensile Strength of Chemical-Resistant Mortar, Grouts and Monolithic Surfacing (Standard No. ASTM C307-03).
71. Experimental and numerical investigation of reinforced concrete slabs under blast loading10.1016/j.engstruct.2019.110125 ↗
72. National Research Council (2003). ISC Security Design Criteria for New Federal Office Buildings and Major Modernization Projects: A Review and Commentary, The National Academies Press.