journal article·2016-06-30Open access

Phase-Sensitive 2D Motion Estimators Using Frequency Spectra of Ultrasonic Echoes

Hideyuki Hasegawa

Applied Sciences· Volume 6· Issue 7

Abstract

Recently, high-frame-rate ultrasound has been extensively studied for measurement of tissue dynamics, such as pulsations of the carotid artery and heart. Motion estimators are very important for such measurements of tissue dynamics. In high-frame-rate ultrasound, the tissue displacement between frames becomes very small owing to the high temporal resolution. Under such conditions, the speckle tracking method requires high levels of interpolation to estimate such a small displacement. A phase-sensitive motion estimator is feasible because it does not suffer from the aliasing effect by such a small displacement and does not require interpolation to estimate a sub-sample displacement. In the present study, two phase-sensitive 2D motion estimators, namely, paired 1D motion estimators and 2D motion estimator with shifted cross spectra, were developed. Phase-sensitive motion estimators using frequency spectra of ultrasonic echoes have already been proposed in previous studies. However, such methods had not taken into account the ambiguity of the frequency of each component of the spectrum. We have proposed a method, which estimates the mean frequency of each component of the spectrum, and the proposed method was validated by a phantom experiment. The experimental results showed that the bias errors in the estimated motion velocities of the phantom were less than or equal to (11.5% in lateral, 2.0% in axial) by the proposed 1D paired motion estimators and (3.0%, 2.0%) by the proposed 2D motion estimators, both of which were significantly smaller than (14.0%, 3.0%) of the conventional phase-sensitive 2D motion estimator.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ultrasound Imaging and Elastography · Photoacoustic and Ultrasonic Imaging · Electrical and Bioimpedance Tomography

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Graduate School of Science and Engineering, University of Toyama, Toyama 930-8555, Japan

Funding

JSPS KAKENHI

References (37)

Show source-provided references
1. Elastography: A quantitative method for imaging the elasticity of biological tissues10.1177/016173469101300201 ↗
2. Noninvasive evaluation of Poisson’s ratio of arterial wall using ultrasound10.1049/el:19970219 ↗
3. Intravascular ultrasound elastography in human arteries: Initial experience in vitro10.1016/S0301-5629(97)00280-9 ↗
4. Elasticity imaging of atheroma with transcutaneous ultrasound -Preliminary study-10.1161/01.CIR.0000078633.31922.8A ↗
5. Noninvasive vascular elastography for carotid artery characterization on subjects without previous history of atherosclerosis10.1118/1.2948320 ↗
6. Noninvasive evaluation of local myocardial thickening and its color-coded imaging10.1109/58.655190 ↗
7. Real time strain rate imaging of the left ventricle by ultrasound10.1016/S0894-7317(98)70151-8 ↗
8. Regional strain and strain rate measurements by cardiac ultrasound: Principles, implementation and limitations10.1053/euje.2000.0031 ↗
9. Smiseth, O.A., Torp, H., Opdahl, A., Haugaa, H., and Urheim, S. (2015). Myocardial strain imaging: How useful is it in clinical decision making?. Eur. Heart J., in press.10.1093/eurheartj/ehv529 ↗
10. Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays10.1121/1.390734 ↗
11. Ultrafast compound imaging for 2-D motion vector estimation: Application to transient elastography10.1109/TUFFC.2002.1041078 ↗
12. Simultaneous imaging of artery-wall strain and blood flow by high frame rate acquisition of RF signals10.1109/TUFFC.2008.978 ↗
13. Ultrafast compound Doppler imaging: Providing full blood flow characterization10.1109/TUFFC.2011.1780 ↗
14. High-frame-rate ultrasound color-encoded speckle imaging of complex flow dynamics10.1016/j.ultrasmedbio.2012.12.016 ↗
15. Measurement of regional pulse wave velocity using very high frame rate ultrasound10.1007/s10396-012-0400-9 ↗
16. Nagaoka, R., Iwasaki, R., Arakawa, M., Kobayashi, K., Yoshizawa, S., Umemura, S., and Saijo, Y. (2015). Basic study of intrinsic elastography: Relationship between tissue stiffness and propagation velocity of deformation induced by pulsatile flow. Jpn. J. Appl. Phys., 54.10.7567/JJAP.54.07HF08 ↗
17. Honjo, Y., Hasegawa, H., and Kanai, H. (2010). Two-dimensional tracking of heart wall for detailed analysis of heart function at high temporal and spatial resolutions. Jpn. J. Appl. Phys., 49.10.1143/JJAP.49.07HF14 ↗
18. A clinical feasibility study of atrial and ventricular electromechanical wave imaging10.1016/j.hrthm.2013.02.028 ↗
19. Pulse-wave propagation in straight-geometry vessels for stiffness estimation: Theory, simulations, phantoms and in vitro findings10.1115/1.4007747 ↗
20. Takahashi, H., Hasegawa, H., and Kanai, H. (2014). Echo speckle imaging of blood particles with high-frame-rate echocardiography. Jpn. J. Appl. Phys., 53.10.7567/JJAP.53.07KF08 ↗
21. Temporal averaging of two-dimensional correlation functions for velocity vector imaging of cardiac blood flow10.1007/s10396-015-0620-x ↗
22. Coherent plane-wave compounding for very high-frame rate ultrasonography and transient elastography10.1109/TUFFC.2009.1067 ↗
23. Multi-transmit beam forming for fast cardiac imaging—a simulation study10.1109/TUFFC.2013.2753 ↗
24. Effect of sub-aperture beamforming on phase coherence imaging10.1109/TUFFC.2014.006365 ↗
25. Effect of element directivity on adaptive beamforming applied to high-frame-rate ultrasound10.1109/TUFFC.2015.006973 ↗
26. Enhancing effect of phase coherence factor for improvement of spatial resolution in ultrasonic imaging10.1007/s10396-015-0673-x ↗
27. Real-time two-dimensional blood flow imaging using an autocorrelation technique10.1109/T-SU.1985.31615 ↗
28. Methods for estimation of subsample time delays of digitized echo signals10.1177/016173469501700204 ↗
29. An axial velocity estimator for ultrasound blood flow imaging, based on a full evaluation of the Doppler equation by means of a two-dimensional autocorrelation approach10.1109/58.393110 ↗
30. Phantom experiment on estimation of shear modulus distribution in soft tissue from ultrasonic measurement of displacement vector field
31. A new method for estimation of velocity vectors10.1109/58.677749 ↗
32. Lateral speckle tracking using synthetic lateral phase10.1109/TUFFC.2004.1320827 ↗
33. Displacement vector measurement using instantaneous ultrasound signal phase–Multidimensional autocorrelation and Doppler methods10.1109/TUFFC.2008.614 ↗
34. Phase-sensitive lateral motion estimator for measurement of artery-wall displacement –Phantom study10.1109/TUFFC.2009.1332 ↗
35. 2-D arterial wall motion imaging using ultrafast ultrasound and transverse oscillations10.1109/TUFFC.2014.006910 ↗
36. A method of polarity estimation for reflected echo in ultrasonotomography
37. Hasegawa, H., Sato, M., and Irie, T. (2016). High resolution wavenumber analysis for investigation of arterial pulse wave propagation. Jpn. J. Appl. Phys., 55.10.7567/JJAP.55.07KF01 ↗