journal article·2019-09-13Open access

Data-Driven Calibration Estimation for Robust Remote Pulse-Oximetry

Mark van Gastel, Wim Verkruysse, Gerard de Haan

Applied Sciences· Volume 9· Issue 18

Abstract

Pulse-oximetry has become a core monitoring modality in most fields of medicine. Typical dual-wavelength pulse-oximeters estimate blood oxygen saturation (SpO2) levels from a relationship between the amplitudes of red and infrared photoplethysmographic (PPG) waveforms. When captured with a camera, the PPG waveforms are much weaker and consequently the measurement is more sensitive to distortions and noises. Therefore, an indirect method has recently been proposed where, instead of extracting the relative amplitudes from the individual waveforms, the waveforms are linearly combined to construct a collection of pulse signals with different pulse signatures, each corresponding to a specific oxygen saturation level. This method has been shown to outperform the conventional ratio-of-ratios based methods, especially when adding a third wavelength. Adding wavelengths, however, complicates the calibration. Inaccuracies in the calibration model threaten the performance of the method. Opto-physiological models have been shown earlier to provide useful calibration parameter estimates. In this paper, we show that the accuracy can be improved using a data-driven approach. We performed 5-fold cross validation on recordings with variations in oxygen saturation and optimized for pulse quality. All evaluated wavelength combinations, also without visible red, meet the required ISO standard accuracy with the calibration from the proposed method. This scalable approach is not only helpful to fine-tune the calibration model, but even allows computation of the calibration model parameters from scratch without prior knowledge of the data acquisition details, i.e., the properties of camera and illumination.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy · Heart Rate Variability and Autonomic Control

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Philips Research, High Tech Campus 34, 5656AE Eindhoven, The Netherlands

Department of Electrical Engineering, Eindhoven University of Technology, 5612AP Eindhoven, The Netherlands

References (21)

Show source-provided references
1. Pulse oximetry screening for clinically unrecognized critical congenital heart disease in the newborns
2. The role of overnight pulse-oximetry in recognition of obstructive sleep apnea syndrome in morbidly obese and non obese patients
3. McDuff, D., Gontarek, S., and Picard, R. (2014, January 26–30). Remote measurement of cognitive stress via heart rate variability. Proceedings of the 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA.10.1109/EMBC.2014.6944243 ↗
4. Non-contact video-based vital sign monitoring using ambient light and auto-regressive models10.1088/0967-3334/35/5/807 ↗
5. Robust respiration detection from remote photoplethysmography10.1364/BOE.7.004941 ↗
6. Contactless multiple wavelength photoplethysmographic imaging: A first step toward “SpO 2 camera” technology10.1007/s10439-005-5763-2 ↗
7. Non-contact detection of oxygen saturation based on visible light imaging device using ambient light10.1364/OE.21.017464 ↗
8. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring10.1038/srep38609 ↗
9. Calibration of contactless pulse oximetry10.1213/ANE.0000000000001381 ↗
10. Camera-based pulse-oximetry-validated risks and opportunities from theoretical analysis10.1364/BOE.9.000102 ↗
11. Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit—A pilot study10.1016/j.earlhumdev.2013.09.016 ↗
12. Near-Continuous Non-Contact Cardiac Pulse Monitoring in a Neonatal Intensive Care Unit in Near Darkness
13. The Importance of Illumination in a Non-Contact Photoplethysmography Imaging System for Burn Wound Assessment10.1117/12.2080699 ↗
14. Yu, M.C., Wu, H., Liou, J.L., Lee, M.S., and Hung, Y.P. (2012, January 1–4). Multiparameter sleep monitoring using a depth camera. Proceedings of the International Joint Conference on Biomedical Engineering Systems and Technologies, Vilamoura, Portugal.
15. Vogels, T., van Gastel, M., Wang, W., and de Haan, G. (2018, January 18–22). Fully-automatic camera-based pulse-oximetry during sleep. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition Workshops, Salt Lake City, UT, USA.10.1109/CVPRW.2018.00183 ↗
16. Van Gastel, M. (2018). Remote Photoplethysmography in Infrared—Towards Contactless Sleep Monitoring. [Ph.D. Thesis, Eindhoven University of Technology].
17. Improved motion robustness of remote-PPG by using the blood volume pulse signature10.1088/0967-3334/35/9/1913 ↗
18. Modelling light distributions of homogeneous versus discrete absorbers in light irradiated turbid media10.1088/0031-9155/42/1/003 ↗
19. Tissue parameters determining the visual appearance of normal skin and port-wine stains10.1007/BF02133165 ↗
20. Spectrophotometry of hemoglobin: Absorption spectra of bovine oxyhemoglobin, deoxyhemoglobin, carboxyhemoglobin, and methemoglobin10.1016/S0305-0491(97)00230-7 ↗
21. International Organization for Standardization (2018). Medical Electrical Equipment—Part 2-61: Particular Requirements for Basic Safety and Essential Performance of Pulse Oximeter Equipment, International Organization for Standardization.