Experimental and Numerical Studies of Controlling Thermal Cracks in Mass Concrete Foundation by Circulating Water
Source abstract
Abstract
This paper summarizes an engineering experience of solving the problem of thermal cracking in mass concrete by using a large project, Zhongguancun No.1 (Beijing, China), as an example. A new method is presented for controlling temperature cracks in the mass concrete of a foundation. The method involves controlled cycles of water circulating between the surface of mass concrete foundation and the atmospheric environment. The temperature gradient between the surface and the core of the mass concrete is controlled at a relatively stable state. Water collected from the well-points used for dewatering and from rainfall is used as the source for circulating water. Mass concrete of a foundation slab is experimentally investigated through field temperature monitoring. Numerical analyses are performed by developing a finite element model of the foundation with and without water circulation. The calculation parameters are proposed based on the experiment, and finite element analysis software MIDAS/CIVIL is used to calculate the 3D temperature field of the mass concrete during the entire process of heat of hydration. The numerical results are in good agreement with the measured results. The proposed method provides an alternative practical basis for preventing thermal cracks in mass concrete.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Properties and Behavior · Concrete and Cement Materials Research · Fire effects on concrete materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100124, China
China Railway Airport Construction Group Co., Beijing 100093, China
Beijing Jialong Group Co., Beijing 100125, China
Funding
National Science and Technology Program, China · National Nature Science Foundation of China · Natural Science Foundation of Beijing, China
References (25)
Show source-provided references
1. (2011). Code for Design of Building Foundation, Standard Press of China. GB 50007–2011.
2. Improved Schmidt Method for Predicting Temperature Development in Mass Concrete
3. Upscaling semi-adiabatic measurements for simulating temperature evolution of mass concrete structures10.1617/s11527-013-0213-3 ↗
4. Influence of cement type on heat of hydration and temperature rise of the mass concrete
5. Schindler, A.K., and Keith, K.P. (2014, January 24–26). Behavior of high-volume fly ash concrete in mass concrete applications. Proceedings of the 1st International Conference on Construction Materials and Structures, Johannesburg, South Africa.10.3233/978-1-61499-466-4-268 ↗
6. Lee, M.H., Chae, Y.S., and Khil, B.S. (2013, January 28–29). Influence of Casting Temperature on the Heat of Hydration in Mass Concrete Foundation with Ternary Cements. Proceedings of the 2nd International Conference on Sustainable Energy and Environmental Engineering (ICSEEE), Shenzhen, China.
7. The influence of thermal-stressing (up to 1000 °C) on the physical, mechanical, and chemical properties of siliceous-aggregate, high-strength concrete10.1016/j.conbuildmat.2013.01.020 ↗
8. Early-age behaviour of the concrete surrounding a turbine spiral case: Monitoring and thermo-mechanical modelling10.1016/j.engstruct.2014.10.009 ↗
9. Thermally induced softening and cracking in concrete with minimal reinforcement10.1007/BF02486396 ↗
10. Experimental Study on Hydration Heat Control of Mass Concrete by Vertical Pipe Cooling Method10.3130/jaabe.14.657 ↗
11. Zhu, J., Zhang, Y.B., and Du, X.F. (2014, January 28–29). Study on Mass Concrete Construction Technology of Raft Foundation in Yantai Ocean Development Center. Proceedings of the 4th International Conference on Structures and Building Materials (ICSBM), Guangzhou, China.
12. Hou, Y.N. (2007). On the control and measures to deal with crack in mass concrete. [Master’s Theses, Shandong University]. (In Chinese).
13. Feasibility Research of Using Phase Change Materials to Reduce the Inner Temperature Rise of Mass Concrete10.1007/s11595-015-1262-y ↗
14. Effect of barium-based phase change material (PCM) to control the heat of hydration on the mechanical properties of mass concrete10.1016/j.tca.2015.05.025 ↗
15. Choi, W.-C., Khil, B.-S., and Chae, Y.-S. (2014). Feasibility of Using Phase Change Materials to Control the Heat of Hydration in Massive Concrete Structures. Sci. World J., 2014.10.1155/2014/781393 ↗
16. Ye, T.X., Yan, H.Q., and Sun, M.H. Patent Search and Analysis of SIPO, A system for controlling cracks of mass concrete foundation by circulating water, China, ZL201420816500.8, (In Chinese).
17. Sun, M.H., Jia, W., and Cao, W.L. Patent Search and Analysis of SIPO, A cooling tank for controlling cracks of mass concrete by circulating water, China ZL201420816495.0, (In Chinese).
18. Ye, T.X., Yan, H.Q., and Sun, M.H. Patent Search and Analysis of SIPO, A cooling system for controlling cracks of mass concrete by circulating water, China, ZL201420816497.X, (In Chinese).
19. Crack Control of Mass Concrete Construction
20. (2009). Code for Construction of Mass Concrete, Standard Press of China. GB50496–2009.
21. Zhu, B.F. (1999). Temperature Stress and Temperature Control of Mass Concrete, China Electric Power Pres.
22. Ge, J.Y. (2013). Guide for Use of Midas Civil Bridge Engineering Software, People's Communications Press.
23. Lu, E.X. (2007). Analysis and controlling of hydration hear temperature in mass concrete pile cap. [Master’s Theses, Hunan University]. (In Chinese).
24. 3D finite element analysis of the transient temperature field of mass concrete
25. (2014). The Specification of Building structure-Quality Evaluation for the Great Wall Cup, Standards Press of Beijing. 1074–2014 DB11/T.