journal article·2021-03-09Open access

Biomechanical Consequences of Tibial Insert Thickness after Total Knee Arthroplasty: A Musculoskeletal Simulation Study

Periklis Tzanetis, Marco A. Marra, René Fluit, Bart Koopman, Nico Verdonschot

Applied Sciences· Volume 11· Issue 5

Abstract

The thickness of the tibial polyethylene (PE) insert is a critical parameter to ensure optimal soft-tissue balancing in the intraoperative decision-making procedure of total knee arthroplasty (TKA). However, there is a paucity of information about the kinetic response to PE insert thickness variations in the tibiofemoral (TF) joint, and subsequently, the secondary effects on the patellofemoral (PF) biomechanics. Therefore, the purpose of this study was to investigate the influence of varying PE insert thickness on the ligament and TF compressive forces, as well as on the PF forces and kinematics, after a cruciate-retaining TKA. A previous patient-specific musculoskeletal model of TKA was adapted to simulate a chair-rising motion in which PE insert thickness was varied with 2 mm increments or decrements compared to the reference case (9 mm), from 5 mm up to 13 mm. Greater PE insert thickness resulted in higher ligament forces and concurrently increased the TF compressive force by 21% (13 mm), but slightly unloaded the PF joint with 7% (13 mm) while shifting the patella distally in the trochlear groove, compared to the reference case. Thinner PE inserts showed an opposite trend. Our findings suggest that the optimal PE insert thickness selection is a trade-off between the kinetic outcomes of the TF and PF joints.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Lower Extremity Biomechanics and Pathologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biomechanical Engineering, University of Twente, 7500 AE Enschede, The Netherlands

Orthopedic Research Laboratory, Radboud Institute for Health Sciences, Radboud University Medical Center, 6500 HB Nijmegen, The Netherlands

References (36)

Show source-provided references
2. Implant design influences patient outcome after total knee arthroplasty: A prospective double-blind randomised controlled trial10.1302/0301-620X.97B1.34254 ↗
3. Mediolateral oversizing influences pain, function, and flexion after TKA10.1007/s00167-013-2443-x ↗
4. Good alignment after total knee arthroplasty leads to faster rehabilitation and better function10.1016/j.arth.2008.03.002 ↗
5. Why are total knee arthroplasties failing today?10.1097/00003086-200211000-00003 ↗
6. Analysis of polyethylene thickness of tibial components in total knee replacement10.2106/00004623-200203000-00006 ↗
7. Effect of polyethylene component thickness on range of motion and stability in primary total knee arthroplasty
8. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement10.2106/00004623-198668070-00010 ↗
9. Polyethylene thickness is a risk factor for wear necessitating insert exchange10.1007/s00264-011-1412-6 ↗
10. Modular Polyethylene Inserts for Total Knee Arthroplasty: Can Surgeons Detect 1-mm Thickness Increments?10.1016/j.arth.2015.11.018 ↗
11. Femoral and tibial insert downsizing increases the laxity envelope in TKA10.1007/s00167-014-3339-0 ↗
12. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses10.1302/0301-620X.74B1.1732274 ↗
13. “Thicker” polyethylene bearings are not associated with higher failure rates in primary total knee arthroplasty10.1016/j.arth.2018.04.026 ↗
14. “Thicker” polyethylene bearings are associated with higher failure rates in primary total knee arthroplasty10.1016/j.arth.2010.04.031 ↗
15. Ding, Z., Nolte, D., Kit Tsang, C., Cleather, D.J., Kedgley, A.E., and Bull, A.M. (2016). In vivo knee contact force prediction using patient-specific musculoskeletal geometry in a segment-based computational model. J. Biomech. Eng., 138.10.1115/1.4032412 ↗
16. The influence of polyethylene bearing thickness on the tibiofemoral kinematics of a bicruciate retaining total knee arthroplasty10.1016/j.knee.2017.03.010 ↗
17. Marra, M.A., Vanheule, V., Fluit, R., Koopman, B., Rasmussen, J., Verdonschot, N., and Andersen, M.S. (2015). A subject-specific musculoskeletal modeling framework to predict in vivo mechanics of total knee arthroplasty. J. Biomech. Eng., 137.10.1115/1.4029258 ↗
18. TLEM 2.0–A comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity10.1016/j.jbiomech.2014.12.034 ↗
19. Grand challenge competition to predict in vivo knee loads10.1002/jor.22023 ↗
20. Skipper Andersen, M., De Zee, M., Damsgaard, M., Nolte, D., and Rasmussen, J. (2017). Introduction to force-dependent kinematics: Theory and application to mandible modeling. J. Biomech. Eng., 139.10.1115/1.4037100 ↗
21. Analysis of musculoskeletal systems in the AnyBody Modeling System10.1016/j.simpat.2006.09.001 ↗
22. Comparison of material properties in fascicle-bone units from human patellar tendon and knee ligaments10.1016/0021-9290(86)90019-9 ↗
23. Functional outcomes used to compare single radius and multiradius of curvature designs in total knee arthroplasty10.1055/s-0031-1299660 ↗
24. Alignment options for total knee arthroplasty: A systematic review10.1016/j.otsr.2017.07.010 ↗
25. Knee cartilage topography, thickness, and contact areas from MRI: In-vitro calibration and in-vivo measurements10.1053/joca.1998.0165 ↗
26. Articular contact in a three-dimensional model of the knee10.1016/0021-9290(91)90019-J ↗
27. Forces in the knee joint whilst rising from a seated position10.1016/0141-5425(84)90053-0 ↗
28. Tibiofemoral joint contact force in deep knee flexion and its consideration in knee osteoarthritis and joint replacement10.1123/jab.22.4.305 ↗
29. How much tibial resection is required in total knee arthroplasty?10.1007/s00264-010-1025-5 ↗
30. Effect of surgical parameters on the biomechanical behaviour of bicondylar total knee endoprostheses–A robot-assisted test method based on a musculoskeletal model10.1038/s41598-019-50399-3 ↗
31. The influence of tibial resection on the PCL in PCL-retaining total knee arthroplasty: A clinical and cadaveric study10.1016/j.jos.2016.07.008 ↗
32. Anterior referencing of tibial slope in total knee arthroplasty considerably influences knee kinematics: A musculoskeletal simulation study10.1007/s00167-017-4561-3 ↗
33. Predicting dissatisfaction following total knee replacement: A prospective study of 1217 patients10.1302/0301-620X.92B9.24394 ↗
34. Anterior knee pain after total knee arthroplasty: A narrative review10.1007/s00264-013-2081-4 ↗
35. Laubach, M., Hellmann, J.T., Dirrichs, T., Gatz, M., Quack, V., Tingart, M., and Betsch, M. (2020). Anterior knee pain after total knee arthroplasty: A multifactorial analysis. J. Orthop. Surg., 28.10.1177/2309499020918947 ↗
36. Patella baja and total knee arthroplasty (TKA): Etiology, diagnosis, and management