journal article·2020-12-05Open access

Comparison of Cone Beam Computed Tomography and Digital Radiography in Detecting Separated Endodontic Files and Strip Perforation

Mehrdad Abdinian, Saba Moshkforoush, Hamidreza Hemati, Parisa Soltani, Mansoure Moshkforoushan, Gianrico Spagnuolo

Applied Sciences· Volume 10· Issue 23

Abstract

The separation of endodontic files and strip perforation are among procedural intraoperative complications which may ultimately lead to the failure of root canal treatment. The aim of the present study was to compare the diagnostic potential of cone beam computed tomography (CBCT) and digital periapical radiographs in detecting separated rotary files and strip perforation in filled canals. Fifty human mandibular molars were selected for this study. The teeth were randomly divided into two groups based on endodontic errors (i.e., file separation and strip perforation). In each group, 25 of 50 mesial canals were randomly chosen for simulating the errors, while the other 25 canals were considered as the control group. In group one, a simulation of the separation of rotary files was performed using ProTaper F2 files. Strip perforation of the root canals in group two was achieved by number 2 and 3 Gates Glidden drills in the coronal third of the root canals. Digital periapical radiographs in two different horizontal angles and high-resolution CBCT scans were obtained from the teeth mounted on a dry human mandible with simulated soft tissue covering. Three experienced observers who were unaware of the study groups evaluated the digital periapical and CBCT image sets in two separate readings. Intraobserver and interobserver agreements, as well as accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), were calculated and compared. Intraobserver and interobserver agreements ranged from poor to excellent and poor to good, respectively. The accuracy, sensitivity, specificity, PPV, and NPV for digital radiography in detecting separated files were 0.950, 0.813, 0.957, 0.929, and 0.880, respectively. The same values for CBCT were 0.747, 0.667, 0.900, 0.833, and 0.783, respectively. For the diagnosis of strip perforation, these values were 0.855, 0.800, 0.909, 0.889, and 0.833 for periapical radiography and 0.955, 1.000, 0.920, 0.926, and 1.000 for CBCT. In conclusion, CBCT was superior for diagnosing strip perforation of the filled root canals, while digital periapical radiographs performed better in the detection of separated rotary files.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Radiography and Imaging · Endodontics and Root Canal Treatments · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Oral and Maxillofacial Radiology, Dental Implants Research Center, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Isfahan 81746, Iran

Dental Students’ Research Committee, School of Dentistry, Isfahan University of Medical Sciences, Isfahan 81746, Iran

Department of Endodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan 81746, Iran

Dentist, Private Practice, Isfahan 81746, Iran

Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples “Federico II”, 80131 Naples, Italy

Funding

Isfahan University of Medical Sciences

References (41)

Show source-provided references
1. Spagnuolo, G., Codispoti, B., Marrelli, M., Rengo, C., Rengo, S., and Tatullo, M. (2018). Commitment of oral-derived stem cells in dental and maxillofacial applications. Dent. J., 6.10.3390/dj6040072 ↗
2. Effectiveness of a reciprocating single file, single cone endodontic treatment approach: A randomized controlled pragmatic clinical trial
3. Clinical, radiographic, and histologic outcome of regenerative endodontic treatment in human teeth using a novel collagen-hydroxyapatite scaffold10.1016/j.joen.2018.10.012 ↗
4. The factors responsible for endodontic treatment failure in the permanent dentitions of the patients reported to the college of dentistry, the University of Aljouf, Kingdom of Saudi Arabia
5. Yamaguchi, M., Noiri, Y., Itoh, Y., Komichi, S., Yagi, K., Uemura, R., Naruse, H., Matsui, S., Kuriki, N., and Hayashi, M. (2018). Factors that cause endodontic failures in general practices in Japan. BMC Oral. Health, 18.10.1186/s12903-018-0530-6 ↗
6. Radiographic study of the problems and failures of endodontic treatment
7. Failure of endodontic treatment: The usual suspects10.4103/1305-7456.175682 ↗
8. Factors influencing the fracture of rotary nickel titanium instruments
9. Effects of sodium hypochlorite and ethylenediaminetetraacetic acid on rotary nickel–titanium instruments evaluated using atomic force microscopy10.1111/j.1365-2591.2010.01799.x ↗
10. Factors contributing to the separation of endodontic files10.1038/bdj.2008.152 ↗
11. Effect of autoclaving on the surfaces of TiN-coated and conventional nickel–titanium rotary instruments10.1111/j.1365-2591.2012.02088.x ↗
12. Repair of a strip perforation with calcium-enriched mixture cement: A case report
13. Radiographic and histological evaluation of persistent periapical lesions associated with endodontic failures after apical microsurgery10.1111/iej.12554 ↗
14. A comparative evaluation of endodontic treatments for immature necrotic permanent teeth based on clinical and radiographic outcomes: A systematic review and meta-analysis10.1111/ipd.12261 ↗
15. Level of knowledge of dental practitioners in Isfahan, Iran about cone-beam computed tomography and digital radiography10.5624/isd.2015.45.2.133 ↗
16. Cone-beam computed tomographic analysis of canal transportation and centering ability of single-file systems10.1016/j.joen.2018.09.011 ↗
17. Alemam, S., Abuelsadat, S., Saber, S., and Elsewify, T. (2020). Accuracy, sensitivity and specificity of three imaging modalities in detection of separated intracanal instruments. G. Ital. Endod., 34.
18. European society of endodontology position statement: Use of cone beam computed tomography in Endodontics: European Society of Endodontology (ESE) developed by10.1111/iej.13187 ↗
19. When and how do endodontic specialists use cone-beam computed tomography?10.1111/aej.12337 ↗
20. A guideline of selecting and reporting intraclass correlation coefficients for reliability research10.1016/j.jcm.2016.02.012 ↗
21. Diagnostic value of cone-beam computed tomography and digital periapical radiography in detection of separated instruments
22. A comparative study between cone-beam computed tomography and periapical radiographs in the diagnosis of simulated endodontic complications10.1111/j.1365-2591.2010.01802.x ↗
23. A comparison of cone-beam computed tomography with periapical radiography in the detection of separated instruments retained in the apical third of root canal-filled teeth10.1016/j.joen.2016.04.016 ↗
24. Detection of fractured endodontic instruments in root canals: Comparison between different digital radiography systems and cone-beam computed tomography10.1016/j.joen.2016.11.017 ↗
25. Comparison of the accuracy of periapical radiography with CBCT taken at 3 different voxel sizes in detecting simulated endodontic complications: An ex vivo study
26. A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations10.5624/isd.2014.44.2.115 ↗
27. The use of cone-beam computed tomography and digital periapical radiographs to diagnose root perforations10.1016/j.joen.2010.12.003 ↗
28. Nikeghbal, K., Zamanian, Z., Shahidi, S., Spagnuolo, G., and Soltani, P. (2020). Designing and fabricating nano-structured and micro-structured radiation shields for protection against CBCT exposure. Materials, 13.10.3390/ma13194371 ↗
29. Mallya, S., and Lam, E. (2019). White and Pharoah’s Oral Radiology E-Book: Principles and Interpretation, Elsevier.
30. The use of Cone Beam Computer Tomography (CBCT) in endodontics10.1007/s40496-019-00239-0 ↗
31. Quantitative evaluation of metal artifacts using different CBCT devices, high-density materials and field of views10.1111/clr.13019 ↗
32. Geometric distortion of panoramic reconstruction in third molar tilting assessments: A comprehensive evaluation10.1259/dmfr.20170467 ↗
33. Special Committee to Revise the Joint AAE/AAOMR Position Statement on use of CBCT in Endodontics (2015). AAE and AAOMR Joint Position Statement: Use of Cone Beam Computed Tomography in endodontics 2015 update. Oral Surg. Oral Med. Oral Pathol. Oral Radiol., 120, 508–512.10.1016/j.oooo.2015.07.033 ↗
34. Artefacts in CBCT: A review10.1259/dmfr/30642039 ↗
35. Quantification of metal artifacts on cone beam computed tomography images10.1111/j.1600-0501.2011.02382.x ↗
36. Influence of voxel size and scan field of view on fracture-like artifacts from gutta-percha obturated endodontically treated teeth on cone-beam computed tomography images10.1016/j.oooo.2016.07.014 ↗
37. Evaluation and reduction of artifacts generated by 4 different root-end filling materials by using multiple cone-beam computed tomography imaging settings10.1016/j.joen.2015.11.002 ↗
38. Assessment of volumetric distortion artifact in filled root canals using different cone-beam computed tomographic devices10.1016/j.joen.2017.03.035 ↗
39. Image artifact in dental cone-beam CT10.1016/j.tripleo.2005.07.027 ↗
40. Suetens, P. (2017). Fundamentals of Medical Imaging, Cambridge University Press.10.1017/9781316671849 ↗
41. Inaccuracy of buccal bone thickness estimation on cone-beam CT due to implant blooming: An ex-vivo study10.1111/jcpe.13183 ↗