journal article·2021-03-30Open access

Analysis of Torque and Force Induced by Rotary Nickel-Titanium Instruments during Root Canal Preparation: A Systematic Review

Myint Thu, Arata Ebihara, Sherif Adel, Takashi Okiji

Applied Sciences· Volume 11· Issue 7

Abstract

The aim of this review was to provide a detailed literature analysis of torque and force generation during nickel-titanium rotary root canal instrumentation. We followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. An electronic search was performed using in PubMed and in journals for articles published in English from 1987 to June 2020 on studies that investigated dynamic torque and force in vivo or in vitro. We assessed article titles and abstracts to remove duplicates, and the titles and abstracts of the remaining articles were screened for eligibility. Full texts were read to verify eligibility by considering predetermined inclusion and exclusion criteria. Fifty-two out of 4096 studies met the inclusion criteria, from which we identified 26 factors that influence torque or force generation. Factors associated with higher torque or force generation and supported by multiple studies with mostly consistent results included convex triangle cross-sectional design, regressive taper, short pitch length, large instrument size, small canal size, single-length preparation technique, long preparation time, deep insertion depth, low rate of insertion, continuous rotation (torque), reciprocating motion (force), lower rotational speed and conventional alloy. However, several factors are interrelated, which obscured the independent effect of each factor, and there was insufficient scientific evidence supporting the influence of some factors.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Occupational health in dentistry · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo 113-8549, Japan

Department of Restorative and Dental Materials, Oral and Dental Research Division, National Research Centre of Egypt, Cairo 12622, Egypt

References (70)

Show source-provided references
1. Torsional strength and toughness of nickel-titanium rotary files10.1016/j.joen.2010.11.028 ↗
2. Dynamic torsional resistance of nickel-titanium rotary instruments10.1016/j.joen.2010.02.016 ↗
3. Lee, J.Y., Kwak, S.W., Ha, J.-H., and Kim, H.-C. (2020). Ex-vivo comparison of torsional stress on nickel–titanium instruments activated by continuous rotation or adaptive motion. Materials, 13.10.3390/ma13081900 ↗
4. Screw-in forces during instrumentation by various file systems10.5395/rde.2016.41.4.304 ↗
5. A comparison of Greater Taper files, ProFiles, and stainless steel files to shape curved root canals10.1067/moe.2001.114159 ↗
6. Influence of rotational speed, torque and operator’s proficiency on ProFile failures10.1046/j.1365-2591.2001.00352.x ↗
7. Cyclic fatigue resistance of three rotary file systems in a dynamic model after immersion in sodium hypochlorite10.1007/s10266-018-0401-2 ↗
8. Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals10.5395/rde.2012.37.4.215 ↗
9. Geometric optimization for development of glide path preparation nickel-titanium rotary instrument10.1016/j.joen.2015.01.025 ↗
10. Crack initiation on the apical root surface caused by three different nickel-titanium rotary files at different working lengths10.1016/j.joen.2010.12.002 ↗
11. Constant insertion rate methodology for measuring torque and apical force in 3 nickel-titanium instruments with different cross-sectional designs10.1016/j.joen.2015.05.021 ↗
12. Comparative analysis of torque and apical force to assess the cutting behaviour of protaper next and protaper universal endodontic instruments10.1111/aej.12351 ↗
13. Effect of pitch length on the behavior of rotary triple helix root canal instruments10.1097/01.DON.0000125877.26495.69 ↗
14. Effects of pitch length and heat treatment on the mechanical properties of the glide path preparation instruments10.1016/j.joen.2016.02.002 ↗
15. Comparison of screw-in effect for several nickel-titanium rotary instruments in simulated resin root canal10.5395/JKACD.2010.35.4.267 ↗
16. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: Explanation and elaboration10.1016/j.jclinepi.2009.06.006 ↗
17. Dynamic torque and apical forces of profile .04 rotary instruments during preparation of curved canals10.1046/j.0143-2885.2001.00494.x ↗
18. Influence of root canal curvature on the screw-in effect of nickel-titanium rotary files in simulated resin root canal10.5395/JKACD.2010.35.5.374 ↗
19. Effect of asymmetry on the behavior of prototype rotary triple helix root canal instruments10.1016/j.joen.2012.12.022 ↗
20. Kwak, S.W., Lee, C.-J., Kim, S.K., Kim, H.-C., and Ha, J.-H. (2019). Comparison of screw-in forces during movement of endodontic files with different geometries, alloys, and kinetics. Materials, 12.10.3390/ma12091506 ↗
21. In vivo evaluation of operative torque generated by two nickel-titanium rotary instruments during root canal preparation10.1055/s-0039-1698369 ↗
22. Comparative analysis of mechanical properties of differently tapered nickeltitanium endodontic rotary instruments10.4012/dmj.2017-312 ↗
23. Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments10.1111/j.1365-2591.1999.tb01408.x ↗
24. Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal10.5395/JKACD.2010.35.5.380 ↗
25. Effect of the glide path establishment on the torque generation to the files during instrumentation: An in vitro measurement10.1016/j.joen.2017.09.016 ↗
26. Torsional performance of ProTaper Gold rotary instruments during shaping of small root canals after 2 different glide path preparations10.1016/j.joen.2016.10.034 ↗
27. Torque and force induced by ProTaper Universal and ProTaper Next during shaping of large and small root canals in extracted teeth10.1016/j.joen.2013.11.019 ↗
28. Torque during canal instrumentation using rotary nickel-titanium files10.1097/00004770-200003000-00007 ↗
29. ProTaper rotary root canal preparation: Assessment of torque and force in relation to canal anatomy10.1046/j.1365-2591.2003.00628.x ↗
30. Analysis of mechanical preparations in extracted teeth using protaper rotary instruments: Value of the safety quotient10.1097/00004770-200309000-00007 ↗
31. Root canal preparation with FlexMaster: Asessment of torque and force in relation to canal anatomy10.1111/j.1365-2591.2003.00742.x ↗
32. Location of contact areas on rotary Profile® instruments in relationship to the forces developed during mechanical preparation on extracted teeth10.1046/j.1365-2591.1999.00200.x ↗
33. Analysis of torque and force with differently tapered rotary endodontic instruments in vitro10.1097/01.don.0000137634.20499.1d ↗
34. Analysis of forces developed during mechanical preparation of extracted teeth using race rotary instruments and profiles10.1111/j.1365-2591.2004.00890.x ↗
35. Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation10.1007/s10266-015-0199-0 ↗
36. The effect of three rotational speed settings on torque and apical force with vortex rotary instruments in vitro10.1016/j.joen.2011.01.022 ↗
37. An in vitro assessment of the physical properties of novel Hyflex nickel–titanium rotary instruments10.1111/j.1365-2591.2012.02067.x ↗
38. Effect of optimum torque reverse motion on torque and force generation during root canal instrumentation with crown-down and single-length techniques10.1016/j.joen.2019.11.007 ↗
39. Real-time dynamic torque values and axial forces during preparation of straight root canals using three different endodontic motors and hand preparation10.1111/iej.12980 ↗
40. A novel platform for in vitro analysis of torque, forces, and three-dimensional file displacements during root canal preparations: Application to ProTaper rotary files10.1016/j.joen.2008.12.017 ↗
41. In vitro assessment of torque and force generated by novel protaper next instruments during simulated canal preparation10.1016/j.joen.2013.07.014 ↗
42. Effect of different speeds of up-and-down motion on canal centering ability and vertical force and torque generation of nickel-titanium rotary instruments10.1016/j.joen.2018.10.002 ↗
43. Behavior of nickel-titanium instruments manufactured with different thermal treatments10.1016/j.joen.2014.06.005 ↗
44. Mechanical properties of a novel nickel-titanium root canal instrument: Stationary and dynamic tests10.1016/j.joen.2020.03.016 ↗
45. Stress generation during pecking motion of rotary nickel-titanium instruments with different pecking depth10.1016/j.joen.2017.04.013 ↗
46. Tahun, I.H.A., Kwak, S.W., Ha, J.-H., Sigurdsson, A., Kayahan, M.B., and Kim, H.-C. (2019). Effective establishment of glide-path to reduce torsional stress during nickel-titanium rotary instrumentation. Materials, 12.10.3390/ma12030493 ↗
47. Dynamic torque and vertical force analysis during nickel-titanium rotary root canal preparation with different modes of reciprocal rotation10.1016/j.joen.2017.05.010 ↗
48. Comparison of torque, force generation and canal shaping ability between manual and nickel-titanium glide path instruments in rotary and optimum glide path motion10.1007/s10266-019-00455-1 ↗
49. Comparison of in vitro torque generation during instrumentation with adaptive versus continuous movement10.1016/j.joen.2019.02.010 ↗
50. Evaluation of selected mechanical properties of niti rotary glide path files manufactured from controlled memory wires10.4012/dmj.2017-276 ↗
51. Vertical load induced with twisted file adaptive system during canal shaping10.1016/j.joen.2016.08.022 ↗
52. Force and vibration generated in apical direction by three endodontic files of different kinematics during simulated canal preparation: An in vitro analytical study10.1177/0954411919854574 ↗
53. Measurement of torque generated during intracanal instrumentation in vivo10.1111/iej.13042 ↗
54. Effect of liquid and past-type lubricants on torque values during simulated rotary root canal instrumentation10.1111/j.1365-2591.2005.00937.x ↗
55. Impact of lubricant parameters on rotary instrument torque and force10.1016/j.joen.2006.11.007 ↗
56. The effect of electropolishing on torque and force during simulated root canal preparation with ProTaper shaping files10.1016/j.joen.2008.09.008 ↗
57. Enhanced root canal-centering ability and reduced screw-in force generation of reciprocating nickel-titanium instruments with a post-machining thermal treatment10.4012/dmj.2018-428 ↗
58. Vertical force induced with WaveOne and WaveOne Gold systems during canal shaping10.1016/j.joen.2018.05.010 ↗
59. Evaluation of time to fracture and vertical forces applied by a novel Gentlefile system for root canal preparation in simulated root canals10.1016/j.joen.2015.12.023 ↗
60. The validity of simulated root canals for the investigation of the prepared root canal shape10.1111/j.1365-2591.1985.tb00450.x ↗
61. Analysis of forces developed during root canal preparation with the balanced force technique10.1046/j.1365-2591.1997.00102.x ↗
62. Evaluation of the cyclic fatigue and torsional resistance of novel nickel-titanium rotary files with various alloy properties10.1016/j.joen.2016.07.015 ↗
63. Comparative evaluation of cyclic fatigue resistance of four different nickel-titanium rotary files with different cross-sectional designs and alloy properties10.1007/s00784-016-1917-x ↗
64. Mechanical properties of orifice preflaring nickel-titanium rotary instrument heat treated using T-Wire technology10.1016/j.joen.2018.08.016 ↗
65. Physical and mechanical properties of twisted or ground nickel–titanium instruments10.1111/iej.12011 ↗
66. Bending properties of rotary nickel-titanium instruments10.1016/S1079-2104(03)00358-5 ↗
67. Flexural stiffness and stresses in nickel-titanium rotary files for various pitch and cross-sectional geometries10.1016/j.joen.2012.06.008 ↗
68. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture10.1016/j.joen.2010.02.010 ↗
69. The relevance of operative torque and torsional resistance of nickel-titanium rotary instruments: A preliminary clinical investigation10.4103/sej.sej_157_19 ↗
70. Mazzoni, A., Pacifici, A., Zanza, A., Giudice, A.D., Reda, R., Testarelli, L., Gambarini, G., and Pacifici, L. (2020). Assessment of real-time operative torque during nickel–titanium instrumentation with different lubricants. Appl. Sci., 10.10.3390/app10186201 ↗