Analysis of the Applicability of Non-Destructive Techniques to Determine In Situ Thermal Transmittance in Passive House Façades
Source abstract
Abstract
Within the European framework, the passive house has become an essential constructive solution in terms of building efficiency and CO2 reduction. However, the main approaches have been focused on post-occupancy surveys, measurements of actual energy consumption, life-cycle analyses in dynamic conditions, using simulation, and the estimation of the thermal comfort. Few studies have assessed the in situ performance of the building fabric of passive houses. Hence, this paper explores the applicability of non-destructive techniques—heat flux meter (HFM) and quantitative infrared thermography (QIRT)—for assessing the gap between the predicted and actual thermal transmittance of passive house façades under steady-state conditions in the Mediterranean climate. Firstly, the suitability of in situ non-destructive techniques was checked in an experimental mock-up, and, subsequently, a detached house was tested in the real built environment. The findings revealed that both Non-Destructive Testing (NDT) techniques allow for the quantification of the gap between the design and the actual façades U-value of a new passive house before its operational stage. QIRT was faster than the HFM technique, although the latter was more accurate. The results will help practitioners to choose the most appropriate method based on environmental conditions, execution of the method, and data analysis.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Building Energy and Comfort Optimization · Thermography and Photoacoustic Techniques · Urban Heat Island Mitigation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Group of Construction Research and Innovation (GRIC), Universitat Politècnica de Catalunya (UPC), C/Colom, 11, Ed. TR5, 08222 Terrassa, Spain
Funding
Government of Catalonia
References (83)
Show source-provided references
1. Key Performance Indicators (KPIs) approach in buildings renovation for the sustainability of the built environment: A review10.1016/j.rser.2015.11.096 ↗
2. Identifying the feasibility of establishing a passive house school in Central Europe: An energy performance and carbon emissions monitoring study in Germany10.1016/j.rser.2019.109256 ↗
3. Are the energy savings of the passive house standard reliable? A review of the as-built thermal and space heating performance of passive house dwellings from 1990 to 201810.1007/s12053-020-09855-7 ↗
4. Experiences from nine passive houses in Sweden—Indoor thermal environment and energy use10.1016/j.buildenv.2013.09.017 ↗
5. Optimisation of a social housing for south of Brazil: From basic performance standard to passive house concept10.1016/j.energy.2018.11.053 ↗
6. Retrofitting a building to passive house level: A life cycle carbon balance10.1016/j.enbuild.2020.110135 ↗
7. Passive house analysis in terms of energy performance10.1016/j.enbuild.2017.03.025 ↗
8. A three-stage optimization methodology for envelope design of passive house considering energy demand, thermal comfort and cost10.1016/j.energy.2019.116723 ↗
9. Life cycle cost optimization of passive energy efficiency improvements in a Toronto house10.1016/j.enbuild.2016.02.015 ↗
10. Cost-effective passive house renovation packages for Swedish single-family houses from the 1960s and 1970s10.1016/j.enbuild.2017.12.018 ↗
11. Whole-building Life Cycle Assessment (LCA) of a passive house of the sub-tropical climatic zone10.1016/j.resconrec.2016.10.010 ↗
12. A state of art of review on interactions between energy performance and indoor environment quality in Passive House buildings10.1016/j.rser.2016.10.039 ↗
13. Comparison of building performance between Conventional House and Passive House in the UK10.1016/j.egypro.2017.12.570 ↗
14. Monitoring the performance of low energy dwellings: Two UK case studies10.1016/j.enbuild.2013.04.002 ↗
15. Bridging the domestic building fabric performance gap10.1080/09613218.2014.979093 ↗
16. Stamp, S. (2015). Assessing Uncertainty in Co-Heating Test: Calibrating a Whole Building Steady State Heat Loss Measurement Method. [Ph.D. Thesis, University College London (UCL)].
17. Johnston, D., and Siddall, M. (2016). The building fabric thermal performance of Passivhaus dwellings—Does it do what it says on the tin?. Sustainability, 8.10.3390/su8010097 ↗
18. Magnitude and extent of building fabric thermal performance gap in UK low energy housing10.1016/j.apenergy.2018.03.096 ↗
19. U-values and traditional buildings. In situ measurements and their comparisons to calculated values
20. Comparing different approaches to in situ measurement of building components thermal resistance10.1016/j.enbuild.2011.05.025 ↗
21. Evaluating in situ thermal transmittance of green buildings masonries: A case study
22. In situ thermal transmittance measurements for investigating differences between wall models and actual building performance10.3390/su70810388 ↗
23. U-value in situ measurement for energy diagnosis of existing buildings10.1016/j.enbuild.2015.06.071 ↗
24. Bienvenido-Huertas, D., Rodríguez-Álvaro, R., Moyano, J.J., Rico, F., and Marín, D. (2018). Determining the U-value of façades using the thermometric method: Potentials and limitations. Energies, 11.10.3390/en11020360 ↗
25. A methodological approach for heat-flow meter data post-processing under different climatic conditions and wall orientations10.1016/j.enbuild.2020.110216 ↗
26. Thermal performance of a building envelope incorporating ETICS with vacuum insulation panels and EPS10.1016/j.enbuild.2014.06.053 ↗
27. A comprehensive experimental approach for the validation of quantitative infrared thermography in the evaluation of building thermal transmittance10.1016/j.apenergy.2014.12.035 ↗
28. A comparison between thermographic and flow-meter methods for the evaluation of thermal transmittance of different wall constructions10.1088/1742-6596/655/1/012007 ↗
29. A longitudinal building fabric and energy performance analysis of two homes built to different energy principles10.1016/j.enbuild.2016.08.052 ↗
30. Samardzioska, T., and Apostolska, R. (2016). Measurement of heat-flux of new type façade walls. Sustainability, 8.10.20944/preprints201608.0037.v1 ↗
31. Qu, Z., Jiang, P., and Zhang, W. (2020). Development and application of infrared thermography non-destructive testing techniques. Sensors, 20.10.3390/s20143851 ↗
32. RESNET—Residential Energy Services Network (2020, October 04). RESNET Interim Guideline for Thermographic Inspections of Buildings. Available online: http://www.resnet.us/standards/RESNET_IR_interim_guidelines.pdf.
33. Quantification of heat energy losses through the building envelope: A state-of-the-art with critical and comprehensive review on infrared thermography10.1016/j.buildenv.2018.09.050 ↗
34. Review of in situ methods for assessing the thermal transmittance of walls10.1016/j.rser.2018.12.016 ↗
35. Thermographic 2D U-value map for quantifying thermal bridges in building façades10.1016/j.enbuild.2020.110176 ↗
36. Evaluation of the infrared thermography technique for capillarity moisture detection in buildings10.1016/j.prostr.2018.11.015 ↗
37. Influence of insulation defects on the thermal performance of walls. An experimental and numerical investigation10.1016/j.jobe.2018.10.029 ↗
38. Garrido, I., Solla, M., Lagüela, S., and Fernández, N. (2020). IRT and GPR techniques for moisture detection and characterization in buildings. Sensors, 20.10.3390/s20226421 ↗
39. To identify the defects illustrated on building façades by employing infrared thermography under shadow10.1016/j.ndteint.2020.102240 ↗
40. Evaluation of infrared thermography methods for analyzing the damage behavior of adhesively bonded repair solutions10.1016/j.compstruct.2020.111991 ↗
41. Thermal transmittance of historical stone masonries: A comparison among standard, calculated and measured data10.1016/j.enbuild.2017.07.002 ↗
42. International Organization for Standardization (2015). Performance of Buildings. Detection of Heat, Air and Moisture Irregularities in Buildings by Infrared Methods—Part 3: Qualifications of Equipment Operators, Data Analysts and Report Writers, ISO. ISO 6781-3:2015.
43. International Organization for Standardization (1998). Thermal Performance of Buildings. Qualitative Detection of Thermal Irregularities in Building Envelopes. Infrared Method, ISO. UNE EN 13187:1998.
44. American Society for Testing Materials (2004). Standard Test Method for Minimum Detectable Temperature Difference for Thermal Imaging Systems, American Society for Testing Materials. ASTM E1311.
45. American Society for Testing Materials (1997). Standard Test Method for Measuring and Compensating for Reflected Ambient Temperature Using Infrared Imaging Radiometers, American Society for Testing Materials. ASTM E1862.
46. Applications of the infrared thermography in the energy audit of buildings: A review10.1016/j.rser.2017.10.031 ↗
47. U-value time series analyses: Evaluating the feasibility of in-situ short-lasting IRT tests for heavy multi-leaf walls10.1016/j.buildenv.2019.05.001 ↗
48. Albatici, R., and Tonelli, A. (2008). Verifica sperimentale in situ, con analisi termografiche e algoritmi di calcolo della transmittanza termica di un elemento costruttivo. Annali Museo Civico di Rovereto. Sezione: Archeologia, Storia, Scienze Naturali, Museo Civico di Rovereto. [23rd ed.].
49. Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site10.1016/j.enbuild.2010.07.010 ↗
50. A pessimistic view of the energy auditing of building structures with the use of infrared thermography10.1134/S1061830910120065 ↗
51. Infrared screening of residential buildings for energy audit purposes: Results of a field test10.3390/en6083859 ↗
52. Ham, Y., and Golparvar-Fard, M. (2013, January 11–15). Automated cost analysis of energy loss in existing buildings through thermographic inspections and CFD analysis. Proceedings of the ISARC-30th International Symposium on Automation and Robotics in Construction and Mining, Montreal, QC, Canada.10.22260/ISARC2013/0117 ↗
53. Quantitative thermography for the estimation of the U-Value: State of art and a case study10.1088/1742-6596/547/1/012016 ↗
54. Appropriate conditions for determining the temperature difference ratio via infrared camera
55. Ibos, L., Monchau, J.-P., Feuillet, V., and Candau, Y. (2015). A comparative study of in-situ measurement methods of a building wall thermal resistance using infrared thermography. Int. Conf. Qual. Control Artif. Vis.10.1117/12.2185126 ↗
56. Estimation of the surface thermal resistance and heat loss by conduction using thermography10.1016/j.applthermaleng.2016.12.033 ↗
57. Application of infrared thermography for the determination of the overall heat transfer coefficient (U-Value) in building envelopes10.1016/j.apenergy.2011.05.014 ↗
58. 3D Visualization of thermal resistance and condensation problems using infrared thermography for building energy diagnostics10.1186/s40327-014-0012-0 ↗
59. Uncertainty and method limitations in a short-time measurement of the effective thermal transmittance on a building envelope using an infrared camera10.1080/14786451.2014.982119 ↗
60. Diagnosis of buildings’ thermal performance—A quantitative method using thermography under non-steady state heat flow10.1016/j.egypro.2015.12.186 ↗
61. Quantitative internal infrared thermography for determining in-situ thermal behaviour of façades10.1016/j.enbuild.2017.06.040 ↗
62. Marshall, A., Francou, J., Fitton, R., Swan, W., Owen, J., and Benjaver, M. (2018). Variation of the U-value measurement of a whole dwelling using infrared thermography under controlled conditions. Buildings, 8.10.3390/buildings8030046 ↗
63. Assessing the influence of operating conditions and thermophysical properties on the accuracy of in-situ measured U-values using quantitative internal infrared thermography10.1016/j.enbuild.2018.04.011 ↗
64. Bienvenido-Huertas, D., Oliveira, M., Rubio-Bullido, C., and Marín, D. (2019). A Comparative analysis of the international regulation of thermal properties in building envelope. Sustainability, 11.10.3390/su11205574 ↗
65. Application of infrared thermography for in-situ determination of building envelope termal properties10.1016/j.jobe.2019.100885 ↗
66. Analysis of the heat flux from the exterior surface of buildings using time sequential thermography10.1016/S1352-2310(99)00136-3 ↗
67. New external convective heat transfer coefficient correlations for isolated low-rise buildings10.1016/j.enbuild.2006.08.001 ↗
68. Comparative analysis of wind loss coefficient (wind heat transfer coefficient) for solar plate collector
69. Verification and application of continuous surface temperature monitoring technique for investigation of nocturnal sensible heat release characteristics by building fabrics10.1016/j.enbuild.2012.06.018 ↗
70. The impact of exterior surface convective heat transfer coefficients on the building energy consumption in urban neighbourhoods with different plan area densities10.1016/j.enbuild.2014.10.062 ↗
71. Madding, R. (2008, January 3–7). Finding R-Values of stud frame constructed houses with IR Thermography. Proceedings of the InfraMation Conference, Reno, NV, USA. Available online: https://www.researchgate.net/publication/285737245_Finding_R-values_of_Stud-Frame_Constructed_Houses_with_IR_Thermography.
72. Earle, R.L., and Earle, M.D. (1983). Unit Operations in Food Processing, Elsevier.
73. Holman, J.P. (1997). Heat Transfer, McGraw Hill. [8th ed.].
74. Influence of ICHTC correlations on the thermal characterization of façades using the quantitative internal infrared thermography method10.1016/j.buildenv.2018.12.056 ↗
75. A comparison of standardized calculation methods for in situ measurements of façades U-value10.1016/j.enbuild.2016.08.072 ↗
76. International Organization for Standardization (2014). Thermal Insulation. Building Elements. Situ Measurement of Thermal Resistance and Thermal Transmittance. Part 1: Heat Flow Meter Method, ISO. ISO 9869:2014.
77. A comparative assessment of the standarized methods for the in-situ measurement of the thermal resistance of buildings walls10.1016/j.enbuild.2017.08.064 ↗
78. American Society for Testing Materials (2007). Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data, American Society for Testing Materials. ASTM C1155-95.
79. In-situ measurement of façades with a low U-value: Avoiding deviations10.1016/j.enbuild.2018.04.012 ↗
80. (2020, October 04). Spain, Royal Decree 314/2006 Approving the Spanish Technical Building Code CTE-DB-HE1. Available online: http://www.boe.es/boe/dias/2006/03/28/pdfs/A11816-11831.pdf.
81. International Organization for Standardization (2012). Building Materials and Products—Hygrothermal Properties—Tabulated Design Values and Procedures for Determining Declared and Design Thermal Values, ISO. UNE EN ISO 10456:2012.
82. International Organization for Standardization (2012). Building Components and Building Elements. Thermal Resistance and Thermal Transmittance. Calculation Method, ISO. UNE EN ISO 6946:2012 (ISO 6946:2007).
83. FLIR Systems (2015). FLIR TOOLS+ Software, FLIR Systems.