Quantitative Monitoring of Dynamic Blood Flows Using Coflowing Laminar Streams in a Sensorless Approach
Source abstract
Abstract
Determination of blood viscosity requires consistent measurement of blood flow rates, which leads to measurement errors and presents several issues when there are continuous changes in hematocrit changes. Instead of blood viscosity, a coflowing channel as a pressure sensor is adopted to quantify the dynamic flow of blood. Information on blood (i.e., hematocrit, flow rate, and viscosity) is not provided in advance. Using a discrete circuit model for the coflowing streams, the analytical expressions for four properties (i.e., pressure, shear stress, and two types of work) are then derived to quantify the flow of the test fluid. The analytical expressions are validated through numerical simulations. To demonstrate the method, the four properties are obtained using the present method by varying the flow patterns (i.e., constant flow rate or sinusoidal flow rate) as well as test fluids (i.e., glycerin solutions and blood). Thereafter, the present method is applied to quantify the dynamic flows of RBC aggregation-enhanced blood with a peristaltic pump, where any information regarding the blood is not specific. The experimental results indicate that the present method can quantify dynamic blood flow consistently, where hematocrit changes continuously over time.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Blood properties and coagulation · Microfluidic and Capillary Electrophoresis Applications · Microfluidic and Bio-sensing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea
Funding
Chosun University
References (71)
Show source-provided references
1. Microcirculation and hemorheology10.1146/annurev.fluid.37.042604.133933 ↗
2. Blood linear viscoelasticity by small amplitude oscillatory flow10.1007/s00397-015-0894-3 ↗
3. The effect of pulsatile versus nonpulsatile blood flow on viscoelasticity and red blood cell aggregation in extracorporeal circulation10.5090/kjtcs.2016.49.3.145 ↗
4. Catheter-based impedance measurements in the right atrium for continuously monitoring hematocrit and estimating blood viscosity changes; an in vivo feasibility study in swine10.1016/j.bios.2004.01.002 ↗
5. Radial dispersion of red blood cells in blood flowing through glass capillaries: The role of hematocrit and geometry10.1016/j.jbiomech.2008.04.033 ↗
6. Direct measurement of the impact of impaired erythrocyte deformability on microvascular network perfusion in a microfluidic device10.1039/b601554a ↗
7. Red cell deformability and its relavance to blood flow10.1146/annurev.ph.49.030187.001141 ↗
8. Ermolinskiy, P., Lugovtsov, A., Yaya, F., Lee, K., Kaestner, L., Wagner, C., and Priezzhev, A. (2020). Eect of red blood cell aging in vivo on their aggregation properties in vitro: Measurements with laser tweezers. Appl. Sci., 10.10.3390/app10217581 ↗
9. Wen, J., Wan, N., Bao, H., and Li, J. (2019). Quantitative measurement and evaluation of red blood cell aggregation in normal blood based on a modified hanai equation. Sensors, 19.10.3390/s19051095 ↗
10. Hemorheology and Microvascular Disorders10.4070/kcj.2011.41.6.287 ↗
11. Microfluidics to mimic blood flow in health and disease10.1146/annurev-fluid-010816-060246 ↗
12. The apparent viscosity of blood flowing in the isolated hindlimb of the dog and its variation with corpuscular concentration10.1113/jphysiol.1933.sp003009 ↗
13. Microvascular Rheology and Hemodynamics10.1080/10739680590894966 ↗
14. Microfluidics analysis of red blood cell membrane viscoelasticity10.1039/C0LC00348D ↗
15. Viscoelasticity of blood and viscoelastic blood analogues for use in polydymethylsiloxane in vitro models of the circulatory system10.1063/1.4804649 ↗
16. Blood viscoelasticity measurement using steady and transient flow controls of blood in a microfluidic analogue of Wheastone-bridge channel10.1063/1.4827355 ↗
17. Improvement of electrical blood hematocrit measurements under various plasma conditions using a novel hematocrit estimation parameter10.1016/j.bios.2012.02.010 ↗
18. Improvement of the accuracy of continuous hematocrit measurement under various blood flow conditions10.1063/1.4871706 ↗
19. Electrochemical hematocrit determination in a direct current microfluidic device10.1002/elps.201400466 ↗
20. Measurement of the hematocrit using paper-based microfluidic devices10.1039/C6LC00895J ↗
21. A physiometer for simultaneous measurement of whole blood viscosity and its determinants: Hematocrit and red blood cell deformability10.1039/C8AN02135J ↗
22. Histogram analysis for smartphone-based rapid hematocrit determination10.1364/BOE.8.003317 ↗
23. Boas, L.V., Faustino, V., Lima, R., Miranda, J.M., Minas, G., Fernandes, C.S.V., and Catarino, S.O. (2018). Assessment of the deformability and velocity of healthy and artificially impaired red blood cells in narrow polydimethylsiloxane (PDMS) microchannels. Micromachines, 9.10.3390/mi9080384 ↗
24. Zeng, N.F., Mancuso, J.E., Zivkovic, A.M., Smilowitz, J.T., and Ristenpart, W.D. (2016). Red blood cells from individuals with abdominal obesity or metabolic abnormalities exhibit less deformability upon entering a constriction. PLoS ONE, 11.10.1371/journal.pone.0156070 ↗
25. Study of individual erythrocyte deformability susceptibility to INFeD and ethanol using a microfluidic chip10.1038/srep22929 ↗
26. Vibration motor-integrated low-cost, miniaturized system for rapid quantification of red blood cell aggregation10.1039/D0LC00619J ↗
27. Influence of red blood cell aggregation on perfusion of an artificial microvascular network10.1111/micc.12317 ↗
28. Microfluidic biosensor for monitoring temporal variations of hemorheological and hemodynamic properties using an extracorporeal rat bypass loop10.1021/ac402505z ↗
29. Hybrid system for ex-vivo hemorheological and hemodynamic analysis: A feasibility study10.1038/srep11064 ↗
30. Periodic and simultaneous quantification of blood viscosity and red blood cell aggregation using a microfluidic platform under in-vitro closed-loop circulation10.1063/1.5017052 ↗
31. Method for flow measurement in microfluidic channels based on electrical impedance spectroscopy10.1007/s10404-011-0843-0 ↗
32. Doppler-based flow rate sensing in microfluidic channels10.3390/s140916799 ↗
33. Optical measurement of flow rate in a microfluidic channel10.1007/s10404-015-1690-1 ↗
34. Real-time measurement of flow rate in microfluidic devices using a cantilever-based optofluidic sensor
35. A simple cantilever system for measurement of flow rates in paper microfluidic devices10.1088/2631-8695/ab4ee5 ↗
36. Measurement of flow velocity and inference of liquid viscosity in a microfluidic channel by fluorescence photobleaching10.1021/la404891g ↗
37. Noncontact and nonintrusive microwave-microfluidic flow sensor for energy and biomedical engineering10.1038/s41598-017-18621-2 ↗
38. A microfluidic flow meter with micromachined thermal sensing elements10.1063/1.5131662 ↗
39. Precision control of flow rate in microfluidic channels using photoresponsive soft polymer actuators10.1039/C7LC00368D ↗
40. Micro-particle image velocimetry measurement of blood flow: Validation and analysis of data pre-processing and processing methods10.1088/0957-0233/23/10/105302 ↗
41. Kang, Y.J. (2020). Microfluidic-Based Biosensor for Blood Viscosity and Erythrocyte Sedimentation Rate Using Disposable Fluid Delivery System. Micromachines, 11.10.3390/mi11020215 ↗
42. Microfluidic-based measurement of erythrocyte sedimentation rate for biophysical assessment of blood in an in vivo malaria-infected mouse10.1063/1.4892037 ↗
43. Microfluidic pressure sensing using trapped air compression10.1039/b617067f ↗
44. Shen, F., Ai, M., Ma, J., Li, Z., and Xue, S. (2020). An easy method for pressure measurement in microchannels using trapped air compression in a one-end-sealed capillary. Micromachines, 11.10.3390/mi11100914 ↗
45. A microfluidic circulatory system integrated with capillary-assisted pressure sensors10.1039/C6LC01427E ↗
46. On-chip pressure sensor using single-layer concentric chambers10.1063/1.4945412 ↗
47. Highly stable liquid metal-based pressure sensor integrated with a microfludic channel10.3390/s150511823 ↗
48. Microfluidic-based measurement of RBC aggregation and the ESR using a driving syringe system10.1039/C7AY02719B ↗
49. Intrinsic Viscosity of Polymers and Biopolymers Measured by Microchip10.1021/ac050932r ↗
50. Rapid measurement of fluid viscosity using co-flowing in a co-axial microfluidic device10.1007/s10404-009-0540-4 ↗
51. Scaling of interface displacement in a microfluidic comparator10.1063/1.2713800 ↗
52. Kim, G., Jeong, S., and Kang, Y.J. (2020). Ultrasound standing wave-based cell-to-liquid separation for measuring viscosity and aggregation of blood sample. Sensors, 20.10.3390/s20082284 ↗
53. Label-free viscosity measurement of complex fluids using reversal flow switching manipulation in a microfluidic channel10.1063/1.4816713 ↗
54. A threshold selection method from gray-level histograms10.1109/TSMC.1979.4310076 ↗
55. Multiplexed microfluidic viscometer for high-throughput complex fluid rheology10.1007/s10404-013-1261-2 ↗
56. A microfluidic viscometer with capcative readout using screen-printed electrodes10.1109/JSEN.2020.3024837 ↗
57. High-throughput and label-free blood-on-a-chip for malaria diagnosis10.1021/acs.analchem.5b04874 ↗
58. Fluidic low pass filter for hydrodynamic flow stabilization in microfluidic environments10.1039/c2lc21163g ↗
59. Zhou, Y., Liu, J., Yan, J., Zhu, T., Guo, S., Li, S., and Li, T. (2020). Standing air bubble-based micro-hydraulic capacitors for flow stabilization in syringe pump-driven systems. Micromachines, 11.10.3390/mi11040396 ↗
60. Design, modeling and fabrication of a constant flow pneumatic micropump10.1088/0960-1317/17/5/007 ↗
61. Lifting gate PDMS microvalves and pumps for microfluidic control10.1021/ac202934x ↗
62. Effect of phase shift on optimal operation of serial-connected valveless micropumps10.1016/j.sna.2014.01.016 ↗
63. A Compliance-Based Microflow Stabilizer10.1109/JMEMS.2009.2021826 ↗
64. The design of an in-plane compliance structure for microfluidical systems10.1016/S0925-4005(01)00964-9 ↗
65. T-matrix computations of light scattering by red blood cells10.1364/AO.37.002735 ↗
66. Optical parameters and scattering properties of red blood cells
67. Vascularized microfluidics and their untapped potential for discovery in diseases of the microvasculature10.1146/annurev-bioeng-091520-025358 ↗
68. Hesh, C.A., Qiu, Y., and Lam, W.A. (2020). Vascularized microfluidics and the blood–endothelium interface. Micromachines, 11.10.3390/mi11010018 ↗
69. Islam, M.M., Beverung, S., and Steward, R. (2017). Bio-inspired microdevices that mimic the human vasculature. Micromachines, 8.10.3390/mi8100299 ↗
70. Microfl uidic blood cell sorting: Now and beyond10.1002/smll.201302907 ↗
71. Blood-on-a-chip10.1146/annurev.bioeng.7.011205.135108 ↗