Blistering Mechanism Analysis of Hydraulic Asphalt Concrete Facing
Source abstract
Abstract
Two years after the Zhanghewan Pumped-Storage Power Station was put into operation, more than 500 blisters appeared in the asphalt concrete facing of the upper reservoir, and nearly half of them ruptured at the surface. The blistering mechanism of the asphalt concrete facing was studied in this paper. Through on-site inspection and coring inspection, it was found that the blistering was caused by the vapor pressure formed by the water enclosed in the middle of the impervious layer during high temperatures. Numerical analysis showed that the temperature 5 cm below the surface could reach 50–60 °C. Through numerical analysis and model tests, the internal water at this temperature may form a vapor pressure of 20 kPa. Finally, the blister size of the asphalt concrete facing at this temperature and pressure was studied with a model test. The possible sources of moisture inside the impervious layer were also analyzed through a core test, which found that moisture was most likely to be introduced by water spraying during rolling.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geotechnical Engineering and Underground Structures · Fire effects on concrete materials · Concrete Properties and Behavior
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Materials, China Institute of Water Resources and Hydropower Research (IWHR), Beijing 100038, China
State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research (IWHR), Beijing 100038, China
Hebei Zhanghewan Pumped Storage Co. Ltd., Jingxing 050300, China
Funding
State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin · China Institute of Water resources and Hydropower Research
References (25)
Show source-provided references
1. Developingof a SBS polymer modified bitumen to avoid low temperature cracks in the asphalt facing of a reservoir in a harsh climate region10.1016/j.conbuildmat.2017.05.200 ↗
2. Xia, S.F., Lu, Y.H., Wang, Z.X., and Zhang, F.C. (2015, January 17). Studies on the key technical problems ofasphalt concrete facing slabs in upper reservoir of Huhhot Pump Storage. Proceedings of the 4th International Conference on Concrete Repair, Rehabilitation and Retrofitting, Leipzig, Germany.10.1201/b18972-34 ↗
3. Wang, Z., Hao, J., Yang, J., Cao, Y., Li, X., and Liu, S. (2019). Experimental Study on Hydraulic Fracturing of High Asphalt Concrete Core Rock-Fill Dam. Appl. Sci., 9.10.3390/app9112285 ↗
4. (1999, January 6). Embankment dams with bituminous concrete facing. Proceedings of the Review and recommendations, Bulletin 114, ICOLD, Paris, France.
5. Peter, T. (2008, January 2). Long time behavior of asphalt concrete lined reservoirs and dams and their foundation. Proceedings of the 1st International Conference on Long Time Effects and Seepage Behavior of Dams, Nanjing, China.
6. Teltayev, B.B., Rossi, O.C., Izmailova, G.G., and Amirbayev, E.D. (2019). Effect of Freeze-Thaw Cycles on Mechanical Characteristics of Bitumens and Stone Mastic Asphalts. Appl. Sci., 9.10.3390/app9030458 ↗
7. Modelling the Stability of Asphalt Concrete with Fuzzy Logic and Statistical Methods for Various Freezing and Thawing Cycles
8. Yang, Q.M., Sun, Z.T., and Ding, P.R. (1988, January 4–5). Asphalt concrete facing for rockfill dams built by directional blasting. Proceedings of the ICOLD 16th Congress, San Francisco, CA, USA.
9. Szling, Z., and Szymański, A. (1991, January 14–17). The origin of and prevention from damage to impervious facings. Proceedings of the ICOLD 17th Congress, Vienna, Austria.
10. Garcia-Gil, L., Miró, R., and Pérez-Jiménez, F.E. (2019). Evaluating the Role of Aggregate Gradation on Cracking Performance of Asphalt Concrete for Thin Overlays. Appl. Sci., 9.10.3390/app9040628 ↗
11. Kong, D., Chen, M., Xie, J., Zhao, M., and Yang, C. (2019). Geometric Characteristics of BOF Slag Coarse Aggregate and its Influence on Asphalt Concrete. Materials, 12.10.3390/ma12050741 ↗
12. Frohnauer, R. (1999, January 6–9). Special application of asphaltic concrete for dam water barrier construction. Proceedings of the Waterpower Conference 1999, Las Vegas, NV, USA.10.1061/40440(1999)4 ↗
13. Schönian, E. (1999). The Shell Bitumen Hydraulic Engineering Handbook, Shell International Petroleum Company Ltd.
14. Experimental study on ground penetrating radar in quality inspection of asphalt concrete impervious facing of pumped storage power station10.1088/1757-899X/423/1/012020 ↗
15. Mallick, R.B., Allen, C.J.L., and Teto, M.R. (2003). An Evaluation of Factors Affecting Permeability of Superpave Designed Pavements. National Center for Asphalt Technology, Auburn University.
16. Sawada, T., Nakazima, Y., and Tanaka, T. (1973, January 2–4). Emperical research and practical design of rockfill dams with asphalt facing. Proceedings of the ICOLD 11th Congress, Madrid, Spain.
17. Robert, G. (2008). Mortimer. Physical Chemistry, Elsevier Inc.. [3rd ed.].
18. Ohe, S. (2019). A Prediction Method of Vapor Pressures by using boiling point data. Fluid Phase Equilibria, in press.10.1016/j.fluid.2019.01.018 ↗
19. Effect of moisture migration and water vapor pressure build-up with the heating rate on concrete spalling type10.1016/j.cemconres.2018.10.021 ↗
20. Dean, J.A. (2003). Lange’s Handbook of Chemistry, Science Press. [2nd ed.].
21. Analytical approach for evaluating temperature field of thermal modified asphalt pavement and urban heat island effect10.1016/j.applthermaleng.2016.11.080 ↗
22. Analytical prediction and field validation of transient temperature field in asphalt pavements10.1007/s11771-015-3039-z ↗
23. Modeling of Temperature Field in Flexible Pavement10.1007/s40098-014-0122-6 ↗
24. Wang, W.J. (2004). Calculation and Analysis Report on Temperature Field and Temperature Stress of Asphalt Concrete Anti-seepage Panel of Xilongchi Pumped Storage Power Station, Xi’an University of Technology.
25. Lian, Z.W., and Wang, L. (2003, January 10). Analysis of two kinds of historical extreme high temperature genesis in Shijiazhuang in the summer of 2002. Proceedings of the 2003 National Major Severe Weather Process Summary and Forecasting Technology Experience Seminar, Chongqing, China.