Investigation of Biomechanical Characteristics of Orthopedic Implants for Tibial Plateau Fractures by Means of Deep Learning and Support Vector Machine Classification
Source abstract
Abstract
An experimental comparative study of the biomechanical behavior of commonly used orthopedic implants for tibial plateau fractures was carried out. An artificial bone model Synbone1110 was used and a Schatzker V type tibial plateau fracture was created in vitro, then stabilized with three different implant types, classic L plate, Locking Plate System (PLS), and Hybrid External Fixator (HEF). The stiffness of the bone—implant assembly was assessed by means of mechanical testing using an automated testing machine. It was found that the classic L plate type internal implant has a significantly higher value of deformation then the other two implant types. In case of the other implant types, PLS had a better performance than HEF at low and medium values of the applied force. At high values of the applied forces, the difference between deformation values of the two types became gradually smaller. An Artificial Neural Network model was developed to predict the implant deformation as a function of the applied force and implant device type. To establish if a clear-cut distinction exists between mechanical performance of PLS and HEF, a Support Vector Machine classifier was employed. At high values of the applied force, the Support Vector Machine (SVM) classifier predicts that no statistically significant difference exists between the performance of PLS and HEF.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone fractures and treatments · Orthopaedic implants and arthroplasty · Hip and Femur Fractures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Sports and Health, University Constantin Brancusi of Targu Jiu, Republicii 1, 210152 Targu Jiu, Romania
2nd Department of Orthopedics and Traumatology, University of Medicine and Pharmacy Timisoara, Bd. Bulbuca Iosif, No. 10, 300736 Timisoara, Romania
Engineering Faculty, University Constantin Brancusi of Targu Jiu, Republicii 1, 210152 Targu Jiu, Romania
References (51)
Show source-provided references
1. Revisiting the Schatzker classification of tibial plateau fractures10.1016/j.injury.2018.11.010 ↗
2. Bone Injury and Fracture Healing Biology
3. Role of angiogenesis in bone repair10.1016/j.abb.2014.07.006 ↗
4. The role of stem cells in fracture healing and nonunion10.1007/s00264-011-1338-z ↗
5. The biology of fracture healing in long bones10.1302/0301-620X.60B2.350882 ↗
6. Osteoblasts exhibit a more differentiated phenotype and increased bone morphogenetic protein production on titanium alloy substrates than on poly-ether-ether-ketone10.1016/j.spinee.2012.02.002 ↗
7. Transarticular joint reconstruction and indirect plate osteosynthesis for complex distal supracondylar femoral fractures10.1016/S0020-1383(97)90113-3 ↗
8. The influence of cyclic compression and distraction on the healing of experimental tibial fractures10.1016/j.orthres.2003.11.007 ↗
9. Effects of Mechanical Factors on the Fracture Healing Process10.1097/00003086-199810001-00015 ↗
10. Implant osseointegration and the role of microroughness and nanostructures: Lessons for spine implants10.1016/j.actbio.2014.03.037 ↗
11. Inflammation, fracture and bone repair10.1016/j.bone.2016.02.020 ↗
12. Nanotopography on titanium promotes osteogenesis via autophagymediated signaling between YAP and β-catenin10.1016/j.actbio.2019.07.007 ↗
13. Biofunctional magnesium coated Ti6Al4V scaffold enhances osteogenesis and angiogenesis in vitro and in vivo for orthopedic application
14. Polydopamine-assisted surface modification for orthopaedic implants
15. Titanium-Based Biomaterials for Preventing Stress Shielding between Implant Devices and Bone10.1155/2011/836587 ↗
16. Theoretical study of the effects of alloying elements on the strength and modulus of β-type bio-titanium alloys10.1016/S0921-5093(98)00886-7 ↗
17. Hybrid fracture fixation systems developed for orthopaedic applications: A general review
18. Fracture Fixation10.1148/rg.236035159 ↗
19. Chris Colton, S.K. (2017). AO Surgery Reference, AO Foundation. [1st ed.].
20. The use of titanium and stainless steel in fracture fixation10.1586/erd.10.53 ↗
21. Internal plate fixation of fractures: Short history and recent developments10.1007/s00776-005-0984-7 ↗
22. Internal Fixation: A Historical Review10.1016/j.cpm.2011.06.006 ↗
23. Locking Compression Plate (LCP). An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix)10.1016/S0020-1383(01)00127-9 ↗
24. How do pilon fractures heal? An analysis of dual plating and bridging callus formation10.1016/j.injury.2020.04.023 ↗
25. Biomechanical behaviours of the bone–implant interface: A review10.1098/rsif.2019.0259 ↗
26. The influence of micro-motion on the tissue differentiation around immediately loaded cylindrical turned titanium implants10.1016/j.archoralbio.2005.04.003 ↗
27. Influence of loading and activity on the primary stability of cementless tibial trays10.1002/jor.22056 ↗
28. Estimation of the migration of tibial components in total knee arthroplasty: A roentgen stereophotogrammetric analysis10.1302/0301-620X.82B2 .9461 ↗
29. Finite Element Stress Analysis of a Push-Out Test Part 1: Fixed Interface Using Stress Compatible Elements10.1115/1.2895434 ↗
30. The effect of micromovement on callus formation10.1007/s007760100014 ↗
31. Effect of controlled axial micromovement on healing of tibial fractures10.1016/S0140-6736(86)92196-3 ↗
32. Failure analysis of a 316L stainless steel femoral orthopedic implant10.1016/j.csefa.2015.12.001 ↗
33. Wang, W.-C., Chen, L.-B., and Chang, W.-J. (2018). Development and Experimental Evaluation of Machine-Learning Techniques for an Intelligent Hairy Scalp Detection System. Appl. Sci., 8.10.3390/app8060853 ↗
34. Miyagi, S., Sugiyama, S., Kozawa, K., Moritani, S., Sakamoto, S.-I., and Sakai, O. (2020). Classifying Dysphagic Swallowing Sounds with Support Vector Machines. Heal., 8.10.3390/healthcare8020103 ↗
35. Machine Learning Accurately Predicts Short-Term Outcomes Following Open Reduction and Internal Fixation of Ankle Fractures10.1053/j.jfas.2018.09.004 ↗
36. Machine learning in human movement biomechanics: Best practices, common pitfalls, and new opportunities10.1016/j.jbiomech.2018.09.009 ↗
37. Machine learning–based identification of hip arthroplasty designs
38. Predicting Temperature in Orthopaedic Drilling using Back Propagation Neural Network10.1016/j.proeng.2013.01.096 ↗
39. Classifying shoulder implants in X-ray images using deep learning10.1016/j.csbj.2020.04.005 ↗
40. A Review on Support Vector Machine for Data Classification
41. Machine learning in medicine: Performance calculation of dementia prediction by support vector machines (SVM)10.1016/j.imu.2019.100200 ↗
42. Yu, W., Liu, T., Valdez, R., Gwinn, M., and Khoury, M.J. (2010). Application of support vector machine modeling for prediction of common diseases: The case of diabetes and pre-diabetes. BMC Med. Informatics Decis. Mak., 10.10.1186/1472-6947-10-16 ↗
43. Effectiveness of Support Vector Machines in Medical Data mining10.24138/jcomss.v11i1.114 ↗
44. Kryszkiewicz, M., Peters, J.F., Rybinski, H., and Skowron, A. (2007). An Improved SVM Classifier for Medical Image Classification. Computer Vision, Springer Science and Business Media LLC. Rough Sets and Intelligent Systems Paradigms. RSEISP 2007. Lecture Notes in Computer Science.10.1007/978-3-540-73451-2 ↗
45. Mechanical comparison of cyclic loading in five different first metatarsal shaft osteotomies10.1177/107110070202300806 ↗
46. Comparison of the trabecular architecture and the isostatic stress flow in the human calcaneus10.1016/j.medengphy.2003.10.003 ↗
47. Placement of screws in the sustentaculum tali. A calcaneal fracture model10.1097/00003086-199807000-00023 ↗
48. Mohamad, W.M., Selamat, M.Z., Bundjali, B., Musa, M., and Dom, H.M. (2016, January 31). Corrosion analysis of the cold work 316L stainless steel in simulated body fluids. Proceedings of the Mechanical Engineering Research Day 2016, Melaka, Malaysia.
49. Subit, D., Arregui, C., Salzar, R., and Crandall, J. (2013, January 11–13). Pediatric, Adult and Elderly Bone Material Properties. Proceedings of the IRCOBI Conference 2013, Gothenburg, Sweden.
50. Anisotropy of Young’s modulus of human tibial cortical bone10.1007/BF02347055 ↗
51. Comparative biomechanical analysis of three implants used in bicondylar tibial fractures