journal article·2020-09-10Open access

A Perspective on Biotribology in Arthroplasty: From In Vitro toward the Accurate In Silico Wear Prediction

Saverio Affatato, Alessandro Ruggiero

Applied Sciences· Volume 10· Issue 18

Abstract

Nowadays hip arthroplasty is recognized as one of the most successful orthopedic surgical procedures, even if it involves challenges to overcome, such that lately, younger and more active patients are in need of total arthroplasty. Wear is still one of the main issues affecting joint prostheses endurance, and often causes loosening accompanied by implant failures. Actual in vitro wear tests executed by mechanical simulators have a long duration, are very expensive, and do not take into account all the possible daily activities of the patients; thus, the challenge to obtain a complete in silico tribological and dynamical model of (bio) tribo-systems could give the possibility to overcome the actual testing procedures and could contribute as a tool for a more accurate tribological design of human prostheses. This prospective paper is intended to underline actual research trends toward the challenge of having accurate numerical algorithms to be used both in preclinical testing and in the optimizations of the prostheses design. With this aim we depicted the possible in silico approach in artificial joints’ wear assessment over time, accounting for contact mechanics, numerical stress–strain analysis, musculoskeletal multibody, and synovial lubrication modelling (boundary/mixed, hydrodynamic, and elastohydrodynamic).
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy

Department of Industrial Engineering, University of Salerno, Via Giovanni Paolo II, nr. 132, 84084 Fisciano, Italy

References (67)

Show source-provided references
1. Rizzoli, I.O. (2020, September 07). REPORT of R.I.P.O. Regional Register of Orthopaedic Prosthetic Implantology Overall Data Hip, Knee and Shoulder Arthroplasty in Emilia-Romagna Region (Italy) 2000–2017. Available online: https://ripo.cineca.it/authzssl/pdf/report_eng_2017.pdf.
2. Pre-clinical validation of joint prostheses: A systematic approach10.1016/j.jmbbm.2008.02.005 ↗
3. Advanced biomaterials for skeletal tissue regeneration: Instructive and smart functions10.1016/j.mser.2007.12.001 ↗
4. (2018). ISO-10993 Biological Evaluation of Medical Devices—Part 1: Evaluation and Testing within a Risk Management Process, ISO International.
5. Boyer, B., Bordini, B., Caputo, D., Neri, T., Stea, S., and Toni, A. (2019). What are the influencing factors on hip and knee arthroplasty survival? Prospective cohort study on 63619 arthroplasties. Orthop. Traumatol. Surg. Res.10.1016/j.otsr.2019.07.020 ↗
6. Registry study on failure incidence in 1,127 revised hip implants with stem trunnion re-use after 10 years of follow-up: Limited influence of an adapter sleeve10.1080/17453674.2019.1618649 ↗
7. Numerical modeling of a mechano-chemical theory for wound contraction analysis10.1016/j.ijsolstr.2009.06.010 ↗
8. Ferguson, K.A., Chatzikalymniou, A.P., and Skinner, F.K. (2017). Combining Theory, Model, and Experiment to Explain How Intrinsic Theta Rhythms Are Generated in an In Vitro Whole Hippocampus Preparation without Oscillatory Inputs. eNeuro, 4.10.1101/115949 ↗
9. How to measure wear following total hip arthroplasty10.5301/hipint.5000003 ↗
10. Banaszkiewicz, P.A. (2014). Effect of femoral head size on wear of the polyethylene acetabular component. Classic Papers in Orthopaedics, Springer.10.1007/978-1-4471-5451-8_24 ↗
11. Effect of femoral head size on wear of the polyethylene acetabular component10.2106/00004623-199072040-00008 ↗
12. In vivo wear of polyethylene acetabular components10.1302/0301-620X.75B2.8444946 ↗
13. Sofka, C.M., Potter, H.G., Figgie, M., and Laskin, R. (2003). Magnetic Resonance Imaging of Total Knee Arthroplasty. Clin. Orthop. Relat. Res., 129–135.10.1097/00003086-200301000-00021 ↗
14. West, J., Romu, T., Thorell, S., Lindblom, H., Berin, E., Holm, A.C.S., Åstrand, L.L., Karlsson, A., Borga, M., and Hammar, M. (2018). Precision of MRI-based body composition measurements of postmenopausal women. PLoS ONE.10.1371/journal.pone.0192495 ↗
15. Magnetic Resonance Imaging in the measurement of whole body muscle mass: A comparison of interval gap methods10.1016/j.radi.2014.09.009 ↗
16. The accuracy and precision of radiostereometric analysis in upper limb arthroplasty—A systematic review of 23 RSA studies10.1080/17453674.2017.1291872 ↗
17. High Precision and Accuracy of Model-Based RSA for Analysis of Wrist Arthroplasty10.1002/jor.24063 ↗
18. Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: Human and canine in vitro models10.1016/S0736-0266(01)00039-0 ↗
19. Accurate accuracy assessment: Review of basic principles
20. Dependence of model-based RSA accuracy on higher and lower implant surface model quality10.1186/1475-925X-12-32 ↗
21. A stereophotogrammetric system for the study of human movements
22. Johnston, C., Kerr, J., Ford, S., O’Byrne, J., and Eustace, S. (2007). MRI as a problem-solving tool in unexplained failed total hip replacement following conventional assessment. Skelet. Radiol.10.1007/s00256-007-0349-8 ↗
23. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 203010.2106/00004623-200704000-00012 ↗
24. Future clinical and economic impact of revision total hip and knee arthroplasty
25. Kurtz, S.M., Lau, E., Watson, H., Schmier, J.K., and Parvizi, J. (2012). Economic burden of periprosthetic joint infection in the united states. J. Arthroplast.10.1016/j.arth.2012.02.022 ↗
26. Dowson, D. (1998). History of Tribology, Wiley Blackwell. [2nd ed.].
27. (2020, May 06). Collins English Dictionary—Complete and Unabridged Invitro.pdf. Available online: https://www.thefreedictionary.com/in+vitro.
28. Tribology and total hip joint replacement: Current concepts in mechanical simulation10.1016/j.medengphy.2008.07.006 ↗
29. ASTM F2003 (2003). ASTM F2003-02(2015) Standard Practice for Accelerated Aging of Ultra-High. Molecular Weight Polyethylene after Gamma Irradiation in Air, ASTM International.
30. (2012). ISO DIS 14242-1 Implants for Surgery—Wear of Total Hip-Joint Prostheses—Part 1: Loading and Displacement Paramenters for Wear-Testing Machines and Corresponding Environmental Conditions for Test, ISO International.
31. ISO-4243/3 (2004). ISO ISO 14243-3:2014(en), Implants for Surgery—Wear of Total Knee-Joint Prostheses—Part 3: Loading and Displacement Parameters for Wear-Testing Machines with Displacement Control and Corresponding Environmental Conditions for Test, ISO International.
32. Abdel-Jaber, S., Belvedere, C., De Mattia, J.S., Leardini, A., and Affatato, S. (2016). A new protocol for wear testing of total knee prostheses from real joint kinematic data: Towards a scenario of realistic simulations of daily living activities. J. Biomech., 49.10.1016/j.jbiomech.2016.07.003 ↗
33. Towards wear testing of high demanding.pdf10.1007/s40430-018-1185-6 ↗
34. Friction of Total Hip Replacements With Different Bearings and Loading Conditions
35. New joints for the Millennium: Wear control in total replacement hip joints10.1243/0954411011535939 ↗
36. Affatato, S., Zanini, F., and Carmignato, S. (2017). Micro X-ray computed tomography mass loss assessment of different UHMWPE: A hip joint simulator study on standard vs. cross-linked polyethylene. PLoS ONE, 12.10.1371/journal.pone.0170263 ↗
37. Affatato, S., Valigi, M.C., and Logozzo, S. (2017). Wear distribution detection of knee joint prostheses by means of 3D optical scanners. Materials, 10.10.3390/ma10040364 ↗
38. Tunev, S.S. (2020, September 07). Differences between in Vitro, in Vivo, and in Silico Studies in Vitro Studies in Vivo Studies in Silico Studies Read. The Marshall Protocol. Autoimmunity Research Foundation. Available online: https://mpkb.org/home/patients/assessing_literature/in_vitro_studies.
39. A cellular automaton model for the study of DNA sequence evolution10.1016/S0010-4825(03)00017-9 ↗
40. Physiological studies in silico
41. Lubrication modeling and wear calculation in artificial hip joint during the gait10.1016/j.triboint.2019.105993 ↗
42. Ruggiero, A., D’Amato, R., and Affatato, S. (2019). Comparison of meshing strategies in THR finite element modelling. Materials, 12.10.3390/ma12142332 ↗
43. Ruggiero, A., Merola, M., and Affatato, S. (2018). Finite element simulations of hard-on-soft hip joint prosthesis accounting for dynamic loads calculated from a Musculoskeletal model during walking. Materials, 11.10.3390/ma11040574 ↗
44. Affatato, S., Merola, M., and Ruggiero, A. (2018). Development of a novel in silico model to investigate the influence of radial clearance on the acetabular cup contact pressure in hip implants. Materials, 11.10.3390/ma11081282 ↗
45. Wear simulation of total knee prostheses using load and kinematics waveforms from stair climbing10.1016/j.jbiomech.2015.09.007 ↗
46. In silico total hip replacement wear testing in the framework of ISO 14242-3 accounting for mixed elasto-hydrodynamic lubrication effects10.1016/j.wear.2020.203420 ↗
47. A numerical model of a 3-dimensional low-density turbidity current in the deep ocean: Testing hypotheses on turbidity currents in deep detail
48. Bridging massive acetabular defects with the triflange cup: 2- to 9-year results10.1097/00003086-200112000-00024 ↗
49. Ruggiero, A. (2020). Milestones in natural lubrication of synovial joints. Front. Mech. Eng., 10.10.3389/fmech.2020.00052 ↗
50. Contact and rubbing of flate surfaces10.1063/1.1721448 ↗
51. Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethylene10.1016/S0043-1648(03)00135-2 ↗
52. Enhanced computational prediction of polyethylene wear in hip joints by incorporating cross-shear and contact pressure in additional to load and sliding distance: Effect of head diameter10.1016/j.jbiomech.2009.01.005 ↗
53. O’Brien, S.T., Luo, Y., and Brandt, J.M. (2015). In-vitro and in-silico investigations on the influence of contact pressure on cross-linked polyethylene wear in total knee replacements. Wear.10.1016/j.wear.2015.02.048 ↗
54. O’Brien, S.T., Bohm, E.R., Petrak, M.J., Wyss, U.P., and Brandt, J.-M. (2014). An energy dissipation and cross shear time dependent computational wear model for the analysis of polyethylene wear in total knee replacements. J. Biomech.10.1016/j.jbiomech.2013.12.017 ↗
55. Nanotribology and MEMS10.1016/S1748-0132(07)70140-8 ↗
56. Bhushan, B. (2005). Nanotribology and nanomechanics. Wear.10.1007/3-540-28248-3 ↗
57. Future perspectives on sustainable tribology10.1016/j.rser.2012.02.064 ↗
58. Biotribology: Recent Progresses and Future Perspectives10.1016/j.bsbt.2015.03.001 ↗
59. Cann, P., and Wimmer, M. (2015). Welcome to the first issue of Biotribology. Biotribology.10.1016/j.biotri.2015.06.001 ↗
60. Martin, J.M., Donnet, C., Le Mogne, T., and Epicier, T. (1993). Superlubricity of molybdenum disulphide. Phys. Rev. B.10.1103/PhysRevB.48.10583 ↗
61. Wang, L., Zhou, X., Ma, T., Liu, D., Gao, L., Li, X., Zhang, J., Hu, Y., Wang, H., and Dai, Y. (2017). Superlubricity of a graphene/MoS2 heterostructure: A combined experimental and DFT study. Nanoscale.10.1039/C7NR01451A ↗
62. Berman, D., Deshmukh, S.A., Sankaranarayanan, S.K.R.S., Erdemir, A., and Sumant, A.V. (2015). Macroscale superlubricity enabled by graphene nanoscroll formation. Science.10.1126/science.1262024 ↗
63. Modeling and simulation in tribology across scales: An overview10.1016/j.triboint.2018.02.005 ↗
64. Morrison, T.M., Pathmanathan, P., Adwan, M., and Margerrison, E. (2018). Advancing regulatory science with computational modeling for medical devices at the FDA’s office of science and engineering laboratories. Front. Med.10.3389/fmed.2018.00241 ↗
65. Innovations in modeling and simulation: Patient-centered healthcare
66. Ruggiero, A., and Zhang, H. (2020). Editorial: Biotribology and Biotribocorrosion Properties of Implantable Biomaterials. Front. Mech. Eng., 6.10.3389/fmech.2020.00017 ↗
67. Shi, L., Guo, Z., and Liu, W. (2015). The recent progress of tribological biomaterials. Biosurface Biotribol., 26.