A Multi-Layer Perceptron Network for Perfusion Parameter Estimation in DCE-MRI Studies of the Healthy Kidney
Source abstract
Abstract
Background: Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is an imaging technique which helps in visualizing and quantifying perfusion—one of the most important indicators of an organ’s state. This paper focuses on perfusion and filtration in the kidney, whose performance directly influences versatile functions of the body. In clinical practice, kidney function is assessed by measuring glomerular filtration rate (GFR). Estimating GFR based on DCE-MRI data requires the application of an organ-specific pharmacokinetic (PK) model. However, determination of the model parameters, and thus the characterization of GFR, is sensitive to determination of the arterial input function (AIF) and the initial choice of parameter values. Methods: This paper proposes a multi-layer perceptron network for PK model parameter determination, in order to overcome the limitations of the traditional model’s optimization techniques based on non-linear least-squares curve-fitting. As a reference method, we applied the trust-region reflective algorithm to numerically optimize the model. The effectiveness of the proposed approach was tested for 20 data sets, collected for 10 healthy volunteers whose image-derived GFR scores were compared with ground-truth blood test values. Results: The achieved mean difference between the image-derived and ground-truth GFR values was 2.35 mL/min/1.73 m2, which is comparable to the result obtained for the reference estimation method (−5.80 mL/min/1.73 m2). Conclusions: Neural networks are a feasible alternative to the least-squares curve-fitting algorithm, ensuring agreement with ground-truth measurements at a comparable level. The advantages of using a neural network are twofold. Firstly, it can estimate a GFR value without the need to determine the AIF for each individual patient. Secondly, a reliable estimate can be obtained, without the need to manually set up either the initial parameter values or the constraints thereof.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: MRI in cancer diagnosis · Radiomics and Machine Learning in Medical Imaging · Advanced MRI Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Electronics, Lodz University of Technology, 90-924 Lodz, Poland
Department of Health and Functioning, Western Norway University of Applied Sciences, 5063 Bergen, Norway
Department of Biomedicine, University of Bergen, 5009 Bergen, Norway
Mohn Medical Imaging and Visualization Centre, Department of Radiology, Haukeland University Hospital, 5021 Bergen, Norway
Funding
Narodowe Centrum Nauki
References (39)
Show source-provided references
1. Gameiro, J., Fonseca, A.J., Jorge, S., and Lopes, A.J. (2018). Acute Kidney Injury Definition and Diagnosis: A Narrative Review. J. Clin. Med., 7.10.3390/jcm7100307 ↗
2. Chronic kidney disease and its complications10.1016/j.pop.2008.01.008 ↗
3. Vander, A.J., Sherman, J.H., and Luciano, D.S. (2001). Human Physiology. The Mechanism of Body Function, McGraw-Hill Publishing. [8th ed.].
4. Measured GFR as a Confirmatory Test for Estimated GFR10.1681/ASN.2009020171 ↗
5. Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique10.1002/jmri.10410 ↗
6. Glomerular filtration rate: Assessment with dynamic contrast enhanced MRI and a cortical compartment model in the rabbit kidney10.1002/jmri.20173 ↗
7. MRI-measurement of perfusion and glomerular filtration in the human kidney with a separable compartment model10.1097/RLI.0b013e31815597c5 ↗
8. Bammer, R. (2016). The basic principles of dynamic contrast-enhanced magnetic resonance imaging. MR and CT Perfusion and Pharmacokinetic Imaging. Clinical Applications and Theory, Wolters Kluwer. Chapter 23.
9. Bammer, R. (2016). Pharmacokinetic models for dynamic contrast-enhanced computed tomography and magnetic resonance imaging. MR and CT Perfusion and Pharmacokinetic Imaging. Clinical Applications and Theory, Wolters Kluwer. Chapter 29.
10. Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values10.1007/s00330-012-2382-9 ↗
11. Ohn, I., and Kim, Y. (2019). Smooth Function Approximation by Deep Neural Networks with General Activation Functions. Entropy, 21.10.3390/e21070627 ↗
12. Liu, L., Ma, D., Azar, A.T., and Zhu, Q. (2020). Neural Computing Enhanced Parameter Estimation for Multi-Input and Multi-Output Total Non-Linear Dynamic Models. Entropy, 22.10.3390/e22050510 ↗
13. Goodfellow, I., Bengio, Y., and Courville, A. (2016). Deep Learning, The MIT Press.
14. Shukla-Dave, A., Lee, N., Stambuk, H., Wang, Y., Huang, W., Thaler, H.T., Patel, S.G., Shah, J.P., and Koutcher, J.A. (2009). Average arterial input function for quantitative dynamic contrast enhanced magnetic resonance imaging of neck nodal metastases. BMC Med. Phys., 9.10.1186/1756-6649-9-4 ↗
15. Experimentally-Derived Functional Form for a Population-Averaged High-Temporal-Resolution Arterial Input Function for Dynamic Contrast-Enhanced MRI10.1002/mrm.21066 ↗
16. Dynamic contrast-enhanced MRI measurement of renal function in healthy participants10.1177/0284185116666417 ↗
17. Johnson, H.J., McCormick, M.M., and Ibanez, L. (2015). The ITK Software Guide: Design and Functionality, Kitware. [4th ed.].
18. Combined T1-based perfusion MRI and MR angiography in kidney: First experience in normals and pathology10.1016/j.ejrad.2007.11.033 ↗
19. The importance of AIF ROI selection in DCE-MRI renography: Reproducibility and variability of renal perfusion and filtration10.1016/j.ejrad.2009.05.041 ↗
20. Automatic detection of arterial input function in dynamic contrast enhanced MRI based on affinity propagation clustering10.1002/jmri.24259 ↗
21. Automatic determination of the arterial input function in dynamic susceptibility contrast MRI: Comparison of different reproducible clustering algorithms10.1007/s00234-015-1493-9 ↗
22. Quantitative dynamic contrast-enhanced MRI for mouse models using automatic detection of the arterial input function10.1002/nbm.1784 ↗
23. Troccaz, J., Grimson, E., and Mösges, R. (1997). 3D Multi-Scale Line Filler for Segmentation and Visualization of Curvilinear Structures in Medical Images, Springer. Proc. CVRMed-MRCAS’97, LNCS.
24. Bammer, R. (2016). MR and CT Perfusion and Pharmacokinetic Imaging. Clinical Applications and Theory, Wolters Kluwer.
25. Parametric Signal Restoration Using Artificial Neural Networks10.1109/10.486256 ↗
26. Witten, I.H., and Frank, E. (2005). Data Mining. Practical Machine Learning Tools and Techniques, Morgan Kaufman, Elsevier. [2nd ed.].
27. Saad, D. (1998). On-line Learning and Stochastic Approxmiations. On-Line Learning in Neural Networks, Cambridge University Press. Chapter 2.10.1017/CBO9780511569920.008 ↗
28. Chollet, F., Allison, K., Wicke, M., Bileschi, S., Bailey, P., Gibson, A., and Allaire, J.J. (2020, August 07). “Keras”. Available online: https://keras.io.
29. Use of contrast-enhanced computed tomography to measure clearance per unit renal volume: A novel measurement of renal function and fractional vascular volume10.1016/S0272-6386(99)70230-1 ↗
30. Dropout: A Simple Way to Prevent Neural Networks from Overfitting
31. Recent advances in trust region algorithms10.1007/s10107-015-0893-2 ↗
32. Renal function measurements from MR renography and a simplified multicompartmental model10.1152/ajprenal.00347.2006 ↗
33. Measurement of glomerular filtration rate by dynamic contrast-enhanced magnetic resonance imaging using a subject-specific two-compartment model10.14814/phy2.12755 ↗
34. Chen, B., Zhang, Y., Song, X., Wang, X., Zhang, J., and Fang, J. (2014). Quantitative Estimation of Renal Function with Dynamic Contrast-Enhanced MRI Using a Modified Two-Compartment Model. PLoS ONE, 9.10.1371/journal.pone.0105087 ↗
35. Assessment of 3D DCE-MRI of the kidneys using non-rigid image registration and segmentation of voxel time courses10.1016/j.compmedimag.2008.11.004 ↗
36. Simulation of phase contrast angiography for renal arterial models10.1186/s12938-018-0471-y ↗
37. Klepaczko, A., Szczypiński, P., Dwojakowski, G., Strzelecki, M., and Materka, A. (2014). Computer simulation of magnetic resonance angiography imaging: Model description and validation. PLoS ONE, 9.10.1371/journal.pone.0093689 ↗
38. The renal arterial resistance index: A marker of renal function with an independent and incremental role in predicting heart failure progression10.1002/ejhf.34 ↗
39. Wearable system for real-time monitoring of hemodynamic parameters: Implementation and evaluation10.1016/j.bspc.2020.101873 ↗