journal article·2020-09-26Open access

On the Use of a Simplified Slip Limit Equation to Predict Screw Self-Loosening of Dental Implants Subjected to External Cycling Loading

Mikel Armentia, Mikel Abasolo, Ibai Coria, Abdel-Hakim Bouzid

Applied Sciences· Volume 10· Issue 19

Abstract

Self-loosening of the prosthetic screws is a major mechanical problem affecting roughly 10% of dental implants, according to the literature. This phenomenon may lead to micro-movements that produce crestal bone loss, peri-implantitis, or structural failure of the implant assembly. In this paper, a simple and effective tool to predict self-loosening under masticatory loads is presented. The loads acting on the screw are obtained from a simple finite element (FE) model, and introduced in a mathematical formula that calculates the torque needed to loosen the screw; self-loosening will occur when this torque becomes zero. In this sense, all the parameters involved in self-loosening phenomenon can be easily identified, and their effect quantified. For validating purposes, 90 experimental tests were performed in a direct stress test bench. As a result, a powerful tool with a maximum experimental error of 7.6% is presented, allowing dental implant manufacturers to predict eventual occurrence of self-loosening in their developed dental implant products and take corrective actions at preliminary design stage. Furthermore, the following clinical implications can be directly derived from the methodology: a higher screw preload, that is a higher tightening torque, improves self-loosening response of the dental implant and, similarly, for a given preload force, higher friction coefficient and screw metric, as well as lower pitch and thread angle values, are also found to be beneficial.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Mechanical Engineering Department, University of the Basque Country, 48013 Bilbao, Spain

R&D Department, Biotechnology Institute I mas D S.L., 01510 Miñano, Spain

Mechanical Engineering Department, École de Technologie Supérieure, Montreal, QC H3C 1K3, Canada

Funding

Eusko Jaurlaritza

References (44)

Show source-provided references
1. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants
2. Bickford, J.H. (2008). Introduction to the Design and Behavior of Bolted Joints. Introduction to the Design and Behavior of Bolted Joints, CRC Press.10.1201/9780849381874 ↗
3. Evaluation of screw loosening on new abutment screws and after successive tightening10.1590/S0103-64402011000100009 ↗
4. Abutment screw loosening in single-implant restorations: A systematic review
5. Comparison of screw loosening, rotation, and deflection among three implant designs10.1016/S0022-3913(05)80134-9 ↗
6. Three-dimensional force measurements on mandibular implants supporting overdentures
7. Preload and torque removal evaluation of three different abutment screws for single standing implant restorations10.1590/S1678-77572008000100011 ↗
8. The Effect of Tissue Entrapment on Screw Loosening at the Implant/Abutment Interface of External- and Internal-Connection Implants: An In Vitro Study10.1111/jopr.12329 ↗
9. Removal torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loading
10. Mechanical complications of dental implants10.1034/j.1600-0501.2000.011S1156.x ↗
11. Jeng, M.-D., Lin, Y.-S., and Lin, C.-L. (2020). Biomechanical Evaluation of the Effects of Implant Neck Wall Thickness and Abutment Screw Size: A 3D Nonlinear Finite Element Analysis. Appl. Sci., 10.10.3390/app10103471 ↗
12. Abutment screw loosening and bending resistance of external hexagon implant system after lateral cyclic loading10.1111/j.1708-8208.2004.tb00223.x ↗
13. Prosthetic outcome of cement-retained implant-supported fixed dental restorations: A systematic review10.1111/j.1365-2842.2011.02209.x ↗
14. A systematic review of the 5-year survival and complication rates of implant-supported single crowns10.1111/j.1600-0501.2007.01453.x ↗
15. Single implant-supported molar and premolar crowns: A ten-year retrospective clinical report10.1016/j.prosdent.2003.08.025 ↗
16. Effect of an antirotation resistance form on screw loosening for single implant-supported crowns10.1016/S0022-3913(00)70040-0 ↗
17. Preventing loosening of implant abutment screws10.1016/S0022-3913(96)90464-3 ↗
18. Factors affecting the abutment screw loosening
19. Comparative study of abutment screw loosening with or without adhesive material10.4047/jap.2017.9.2.99 ↗
20. The Effect of Abutment Screw Length on Screw Loosening in Dental Implants with External Abutment Connections After Thermocycling10.11607/jomi.3125 ↗
21. Effect of lubricant on the reliability of dental implant abutment screw joint: An in vitro laboratory and three-dimension finite element analysis10.1016/j.msec.2016.11.041 ↗
22. Influence of the coating material on the loosing of dental implant abutment screw joints10.1016/j.msec.2005.08.011 ↗
23. Effects of surface coating on the screw loosening of dental abutment screws10.1007/BF03027417 ↗
24. The effect of clockwise and counterclockwise twisting moments on abutment screw loosening10.1111/j.1600-0501.2011.02282.x ↗
25. The relationship between implant preload and screw loosening on implant-supported prostheses10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2 ↗
26. Finite element analysis to determine implant preload10.1016/j.prosdent.2003.09.012 ↗
27. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems10.1016/S0022-3913(99)70243-X ↗
28. New criteria for self-loosening of fasteners under vibration
29. Criteria for Self Loosening of Fasteners Under Vibration10.1108/eb034949 ↗
30. Haviland, G.S. (1981). Unraveling the Myths of Fastener World, SAE Technical Papers; SAE International.10.4271/810509 ↗
31. A mathematical model for vibration-induced loosening of preloaded threaded fasteners10.1115/1.2981165 ↗
32. Novel formulation of the tightening and breakaway torque components in threaded fasteners10.1115/1.2767354 ↗
33. Analytical Modeling of Self-Loosening of Bolted Joints Subjected to Transverse Loading10.1115/1.4042798 ↗
34. Development of design charts for bolts preloaded up to the plastic range10.1115/1.3439041 ↗
35. Juvinall, R.C., and Saunders, H. (2012). Fundamentals of Machine Component Design, John Wiley & Sons, INC. [5th ed.]. Chapter 10.
36. Armentia, M., Abasolo, M., Coria, I., and Albizuri, J. (2020). Fatigue Design of Dental Implant Assemblies: A Nominal Stress Approach. Metals, 10.10.3390/met10060744 ↗
37. ISO 14801:2007 Dentistry (2007). Dynamic Fatigue Test for Endosseous Dental Implants, ISO.
38. Nondestructive Bolt Preload Measurement10.30958/ajte.5-2-1 ↗
39. Little, R. (1975). Manual on Statistical Planning and Analysis, ASTM International. [17th ed.].10.1520/STP588-EB ↗
40. Probabilistic analysis of preload in the abutment screw of a dental implant complex10.1016/S0022-3913(08)60177-8 ↗
41. An abutment screw loosening study of a Diamond Like Carbon-coated CP titanium implant10.1111/j.1365-2842.2004.01475.x ↗
42. Effect of surface modification on the long-term stability of dental implant abutment screws by plasma nitriding treatment10.1016/j.surfcoat.2020.126089 ↗
43. Effect of the coefficient of friction and tightening speed on the preload induced at the dental implant complex with the finite element method10.1016/j.prosdent.2014.09.021 ↗
44. Criterion for preventing self-loosening of preloaded cap screws under transverse cyclic excitation10.1115/1.4003596 ↗