Fault Investigation of Circulation Pumps to Detect Impeller Clogging
Source abstract
Abstract
Pumps have a wide range of applications. Methods for fault detection of motors are increasingly being used for pumps. In the context of this paper, a test bench is built to investigate circulation pumps for faults. As a use case, the fault of impeller clogging was first measured and then examined with the help of motor current signature analysis. It can be seen that there are four frequencies at which there is an increase in amplitude in case of a fault. The sidebands around the supply frequency are in particular focus. The clogging of three and four of a total of seven channels leads to the highest amplitudes at the fault frequencies. The efficiency is reduced by 9 to 15% in case of faulty operation. These results indicate that the implementation of fault detection algorithms on the pump electronics represents added value for the pump operator. Furthermore, the results can be transferred to other applications.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Machine Fault Diagnosis Techniques · Power Transformer Diagnostics and Insulation · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
University of Applied Sciences Kaiserslautern, Schoenstraße 11, 67659 Kaiserslautern, Germany
Instituto Tecnológico de la Energía, Universitat Politècnica de València (UPV), Camino de Vera s/n, 46022 Valencia, Spain
References (24)
Show source-provided references
1. Thomas, S., and Barthel, C. (2009). Technology Procurement for very Energy Efficient Circulation Pumps, Wuppertal Institut für Klima, Umwelt und Energie GmbH. Energy+ Pumps Project.
2. Rasmussen, K.F., and Thorup, N. (2002, January 18–20). Permanent magnet motors find their way to circulator pumps. Proceedings of the 3rd International Conference EEMODS’02 Energy Efficiency in Motor Driven Systems, Treviso, Italy.
3. Vairamohan, B., Rajagopalan, S., Samotyj, M., and Ammi, A. (2011, January 12–14). New circulator pump design shows higher energy savings opportunity. Proceedings of the Seventh International Conference EEMODS 11: Energy Efficiency in Motor Driven Systems, Alexandria, FL, USA.
4. Eser, M., Kasnakoglu, C., and Benli, B.B. (2019, January 28–30). Vector Control of PMSM in Circulation Pump Application and an Adaptive Approach for EEI Optimization. Proceedings of the 2019 11th International Conference on Electrical and Electronics Engineering (ELECO), Bursa, Turkey.10.23919/ELECO47770.2019.8990438 ↗
5. Eckl, M., Wurm, F., Liu, S., Urschel, S., Schullerer, J., Schaab, J., and Kowalski, K. (2019, January 24–25). New control mode to decrease energy consumption of circulator pumps. Proceedings of the 4th International Rotating Equipment Conference, Wiesbaden, Germany.
6. Eckl, M., and Schullerer, J. (2020, September 24). Method for the Self-Diagnosis of the Mechanical and/or Hydraulic State of a Centrifugal Pump. WO2019141658A1. Available online: https://patents.google.com/patent/WO2019141658A1/en.
7. Wilo-Stratos PICO (2020, September 24). Installation and Operating Instructions. Available online: https://cms.media.wilo.com/dcidocpfinder/wilo108421/1270563/wilo108421.pdf.
8. Grundfos MAGNA3 (2020, September 24). Installation and Operating Instructions. Available online: https://us.grundfos.com/content/dam/NAMREG/Literature/TechnicalLiterature/I&O-Magna3-Model-D.pdf.
9. Herrera-Guachamin, J., and Antonino-Daviu, J. (2019, January 14–17). Laboratory experiments for the evaluation of the efficiency of induction motors operating under different electrical and mechanical faults. Proceedings of the IECON 2019—45th Annual Conference of the IEEE Industrial Electronics Society, Lisbon, Portugal.10.1109/IECON.2019.8927328 ↗
10. Thomson, W.T., and Gilmore, R.J. (2003, January 11). Motor current signature analysis to detect faults in induction motor drive—Fundamentals, data interpretation, and industrial case histories. Proceedings of the Thirty-Second Turbomachinery Symposium, Huston, TX, USA.
11. Fault diagnosis techniques for permanent magnet ac machine and drives—A review of current state of the art10.1109/TTE.2018.2819627 ↗
12. Kostic-Perovic, D., Arkan, M., and Unsworth, P. (2000, January 8–12). Induction motor fault detection by space vector angular fluctuation. Proceedings of the Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129), Rome, Italy.
13. Irfan, M., and Glowacz, A. (2019). Design of a novel electric diagnostic technique for fault analysis of centrifugal pumps. Appl. Sci., 9.10.3390/app9235093 ↗
14. Tiana, X., Fenga, G., Chenb, Z., Albraika, A., Guab, F., and Balla, A.D. (2014, January 16–18). The investigation of motor current signals from a centrifugal pump for fault diagnosis. Proceedings of the 27th International Congress of Condition Monitoring and Diagnostic Engineering, Brisbane, Australia.
15. Clogged impeller diagnosis in the centrifugal pump using the vibration and motor current analysis
16. Incipient detection of cavitation phenomenon in centrifugal Pumps10.1109/TIA.2013.2267709 ↗
17. Becker, V., Schwamm, T., Urschel, S., and Antonino-Daviu, J.A. (2020, January 23–26). Detection of rotor and impeller faults in wet rotor pumps. Proceedings of the 24th International Conference on Electrical Machines (ICEM), Gothenburg, Sweden.10.1109/ICEM49940.2020.9270767 ↗
18. A compact error management algorithm to minimize false-alarm rate of motor/generator faults in (hybrid) electric vehicles10.1109/JESTPE.2014.2302902 ↗
19. A simple real-time fault signature monitoring tool for motor-drive-embedded fault diagnosis systems10.1109/TIE.2010.2051936 ↗
20. Choi, S., Akin, B., Rahimian, M.M., and Toliyat, H.A. (2009, January 15–19). Fault Diagnosis Implementation of Induction Machines based on Advanced Digital Signal Processing Techniques. Proceedings of the 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition, Washington, DC, USA.10.1109/APEC.2009.4802778 ↗
21. Dynamic Eccentricity and Demagnetized Rotor Magnet Detection in Trapezoidal Flux (Brushless DC) Motors Operating Under Different Load Conditions10.1109/TPEL.2007.904183 ↗
22. Influence of Blade Pass Frequency Vibrations on MCSA-Based Rotor Fault Detection of Induction Motors10.1109/TIA.2017.2672526 ↗
23. Bonaldi, E.L., da Silva, J.G.B., Oliveira, L.L., and Lambert-Torres, G. (2012). Predictive maintenance by electrical signature analysis to induction motors. Induction Motors—Modelling and Control, InTech. [1st ed.].
24. Gülich, J.F. (2014). Centrifugal Pumps, Springer. [3rd ed.].10.1007/978-3-642-40114-5 ↗