Occupational Radiation Dose, Especially for Eye Lens: Hp(3), in Medical Staff Members Involved in Computed Tomography Examinations
Source abstract
Abstract
Radiation dose management of medical staff has become increasingly important. Particularly, based on the statement by the International Commission on Radiological Protection (ICRP) in 2011, a new lower equivalent dose limit for the eye lens is being established in each country. Although many reports have discussed the occupational radiation dose in interventional radiology (IR), few studies have examined the dose during computed tomography (CT) examinations. This study investigated the radiation dose exposure to medical staff present in the CT room during irradiation, with particular focus on the exposure to eye lens. The radiation dose exposure to those who assist patients during head, chest and upper abdomen CT examination was measured in a phantom study. The radiation dose exposure with scattered radiation was never negligible (i.e., high); Hp(3) was the highest in head CT examination, at 0.44 mSv per examination. Furthermore, the shielding effect of radiation protection glasses was large, and radiation protection glasses are useful tools for the medical staff who are involved in CT examinations. The justification and optimisation should be carefully considered in assistant actions.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Radiation Dose and Imaging · Radiology practices and education · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate School of Health Sciences, Hirosaki, University Hirosaki, Aomori 036-8564, Japan
Saisekai Yokohamashi Tobu Hospital, Tsurumi, Yokohama, Kanagawa 230-0012, Japan
Towada City Hospital, Towada, Aomori 034-0093, Japan
Narumi Hospital, Hirosaki, Aomori 036-8183, Japan
Funding
JSPS KAKENHI
References (30)
Show source-provided references
1. Radiation doses delivered to radiologists during contrast-enhanced helical-CT examinations10.1007/s003300050949 ↗
2. Occupational doses during the injection of contrast media in paediatric CT procedures10.1093/oxfordjournals.rpd.a006129 ↗
3. Investigation of qualitative and quantitative factors related to radiological exposure to nursing staff during computed tomography examinations10.1097/HP.0000000000000186 ↗
4. Improving radiation awareness and feeling of personal security of non-radiological medical staff by implementing a traffic light system in computed tomography10.1055/s-0041-110450 ↗
5. Effective techniques to reduce radiation exposure to medical staff during assist of X-ray computed tomography examination10.6009/jjrt.2018_JSRT_74.4.326 ↗
6. Radiation Council (2021, March 19). Secretariat of Nuclear Regulation Authority of Japan, Available online: https://www.nsr.go.jp/data/000209654.pdf.
7. Estimation of the number of CT procedures based on a nationwide survey in Japan10.1097/HP.0b013e3181f497ef ↗
8. Estimates of the number of patients with high cumulative doses through recurrent CT exams in 35 OECD countries10.1016/j.ejmp.2020.07.014 ↗
9. (2021, March 19). 2-3 Patient Assistance in X-ray Examination Room. Guideline for Radiation Safety of Medical Staff (Provisional Translation). Available online: https://www.jsrt.or.jp/data/wp-content/uploads/2020/10/suisyoutai_pdf2020.10.1.pdf.
10. International Commission on Radiological Protection (2011). Statement on Tissue Reactions, ICRP Ref 4825-3093-1464.
11. International Commission on Radiological Protection (2012). Publication 118: ICRP Statement on Tissue Reactions/Early and Late Effects of Radiation in Normal Tissues and Organs-Threshold Doses for Tissue Reactions in a RADIATION Protection Context, Elsevier Ltd. Annual of ICRP.
12. Evaluation of patient dose and operator dose in swallowing CT studies performed with a 320-detector-row multislice CT scanner10.1007/s12194-012-0148-3 ↗
13. Occupational eye dose in interventional cardiology procedures10.1038/s41598-017-00556-3 ↗
14. Occupational radiation exposure of the eye in neurovascular interventional physician10.1093/rpd/ncy285 ↗
15. Evaluation of eye lens doses of interventional cardiologists10.1093/rpd/ncw321 ↗
16. Image quality and radiation dose with low tube voltage in coronary CT angiography: An experimental study with normal type and soft plaque phantom
17. A phantom study to determine the optimal placement of eye dosemeters on interventional cardiology staff
18. The impact on the eye lens of radiation emitted by natural radionuclides (lead-210) present in radiation protection glasses10.1093/rpd/ncz252 ↗
19. Development of the new glass badge
20. (2021, April 30). Japan Accreditation Board. Available online: https://www.jab.or.jp/system/service/upload/RTL04590/RTL04590-en.pdf.
21. (2021, April 09). Chiyoda Technol Corporation. Available online: https://www.c-technol.co.jp/eng/e-reason.
22. Performance of the DOSIRIS™ eye lens dosimeter10.1088/1361-6498/ab2729 ↗
23. Japan Network for Research and Information on Medical Exposure (2021, March 19). National Diagnostic Reference Levels in Japan (2020)—Japan DRLs 2020. Available online: http://www.radher.jp/J-RIME/report/DRL2020_Engver.pdf.
24. Ministry of Health, Labour and Welfare (2021, March 19). Notice No 254, Available online: https://www.mhlw.go.jp/content/11300000/000689300.pdf.
25. Funao, H., Ishii, K., Momoshima, S., Iwanami, A., Hosogane, N., Watanabe, K., Nakamura, M., Toyama, Y., and Matsumoto, M. (2014). Surgeons’ exposure to radiation in single-and multi-level minimally invasive transforaminal lumbar interbody fusion; a prospective study. PLoS ONE, 9.10.1371/journal.pone.0095233 ↗
26. Radiation dose of nurses during IR procedures: A controlled trial evaluating operator alerts before nursing tasks10.1016/j.jvir.2014.03.021 ↗
27. Effect of protective lead curtains on scattered radiation exposure to the operator during ureteroscopy for stone disease: A controlled trial10.1016/j.urology.2017.07.036 ↗
28. International Commission on Radiological Protection (2000). ICRP Publication 87: Managing Patient Dose in Computed Tomography, Pergamon Press. Annual of ICRP.
29. International Commission on Radiological Protection (1987). ICRP Publication 51: Data for Use in Protection against External Radiation, Pergamon Press. Annual of ICRP.
30. Measuring scatter radiation in diagnostic X rays for radiation protection purposes10.1093/rpd/ncv093 ↗