journal article·2021-07-22Open access

Invisalign® vs. Spark™ Template: Which Is the Most Effective in the Attachment Bonding Procedure? A Randomized Controlled Trial

Giovanni Bruno, Antonio Gracco, Martina Barone, Sabrina Mutinelli, Alberto De Stefani

Applied Sciences· Volume 11· Issue 15

Abstract

Aim: The primary aim of this randomized clinical trial was to evaluate the percentage of attachments’ debonding at the template’s removal both in Invisalign® and Spark™ systems. The secondary aim was to define the percentage of patients who did not show attachments’ debonding at the template’s removal. Materials and methods: Eighty patients who needed an orthodontic treatment were included in the study and randomly assigned to a treatment to be performed with Spark™ or Invisalign® clear aligners system. The patients were equally divided into two groups: Spark group (n = 40) and Invisalign group (n = 40). At the template removal by the teeth surface after the attachment bonding procedure, in each patient of both groups, it was assessed if some attachment debonding occurred and the number of attachments detached. Results: The Spark group showed, in general, a lower frequency in debonding in comparison with the Invisalign group, as 87.5% of patients in the Spark group did not show any bonding failure versus 27.5% in those of the Invisalign group. Conclusions: At template removal, the Spark™ template showed less attachment debonding compared to the Invisalign® template. The Spark™ template can be considered more effective in attachments’ transferring to the tooth surface than the Invisalign® one.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders · dental development and anomalies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Dentistry, University of Padova, 35122 Padova, Italy

References (12)

Show source-provided references
1. Effects of variable attachment shapes and aligner material on aligner retention10.2319/091014-637.1 ↗
2. Efficacy of clear aligners in controlling orthodontic tooth movement: A systematic review10.2319/061614-436.1 ↗
3. Predictability of orthodontic movement with orthodontic aligners: A retrospective study10.1186/s40510-017-0190-0 ↗
4. Risk Factors of Composite Attachment Loss in Orthodontic Patients during Orthodontic Clear Aligner Therapy: A Prospective Study10.1155/2021/6620377 ↗
5. Scanning electron microscopy analysis of aligner fitting on anchorage attachments10.1007/s00056-018-00167-1 ↗
6. Surface wear of resin composites used for Invisalign® attachments
7. D’Antò, V., Muraglie, S., Castellano, B., Candida, E., Sfondrini, M.F., Scribante, A., and Grippaudo, C. (2019). Influence of Dental Composite Viscosity in Attachment Reproduction: An Experimental In Vitro Study. Materials, 12.10.3390/ma12234001 ↗
8. Lin, S., Huang, L., Li, J., Wen, J., Mei, L., Xu, H., Zhang, L., and Li, H. (2021). Assessment of preparation time and 1-year Invisalign aligner attachment survival using flowable and packable composites. Angle Orthod.10.2319/063020-598.1 ↗
9. MicroCT X-ray comparison of aligner gap and thickness of six brands of aligners: An In-Vitro study10.1186/s40510-020-00312-w ↗
10. A comparative study of two different clear aligner systems10.1186/s40510-014-0031-3 ↗
11. The 50 most-cited articles on clear aligner treatment: A bibliometric and visualized analysis10.1016/j.ajodo.2020.11.029 ↗
12. Efficiency, effectiveness and treatment stability of clear aligners: A systematic review and meta-analysis10.1111/ocr.12177 ↗