Design and Performance of Photon Imaging Detector Based on Cross-Strip Anode with Charge Induction
Source abstract
Abstract
Imaging detectors based on a microchannel plate (MCP) and charge division anode with charge induction have broad applications in particles (photons, neutrons, ions, and electrons) detection. However, the application of a charge induction readout mode is mostly focused on planar anodes, and there are few reports on double-layer cross-strip (XS) anodes with high spatial resolution and low gain requirements. In this paper, we design the parameters of the resistive layer and XS anode by theoretical derivation and the three-dimensional finite element method, including the sheet resistance, substrate thickness, strip width, and insulation thickness. The performance of the XS detector is characterized with the help of a resolution target and full field illumination using three different centroid algorithms. We conclude that the modified center of gravity (MCoG) has best imaging performance, which achieves a spatial resolution of 44.2 μm with a periodic distortion about 25.8%.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Photocathodes and Microchannel Plates · Radiation Therapy and Dosimetry · Radiation Detection and Scintillator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
University of Chinese Academy of Sciences, Beijing 100049, China
Funding
National Natural Science Foundation of China
References (17)
Show source-provided references
1. Montcel, B., Torregrossa, M., and Poulet, P. (2004, January 14–17). Optode Positioning in Time-Resolved Neurological Nearinfrared Imaging. Proceedings of the Biomedical Topical Meeting, OSA Technical Digest, Miami Beach, FL, USA.10.1364/BIO.2004.WF11 ↗
2. Rueck, A., Dolp, F., and Scalfi-Happ, C. (2003, January 22). Time-Resolved Microspectrofluorometry and Fluorescence Lifetime Imaging Using Ps Pulsed Diode Lasers in Laser Scanning Microscopes. Proceedings of the European Conference on Biomedical Optics, Munich, Germany.10.1117/12.500456 ↗
3. Linearly excited indium fluorescence imaging for temporally resolved high-precision flame thermometry10.1364/OL.381552 ↗
4. Tremsin, A.S., Siegmund, O., and Hull, J.S. (2007, January 16). High Resolution Photon Counting Detection System for Advanced Inelastic X-ray Scattering Studies. Proceedings of the 2006 IEEE Nuclear Science Symposium Conference Record, San Diego, CA, USA.10.1109/NSSMIC.2006.355959 ↗
5. Wide-field auroral imager onboard the Fengyun satellite
6. UV MCP Detectors for WSO-UV: Cross Strip Anode and Readout Electronics10.1109/TNS.2013.2248096 ↗
7. Position sensitive anodes for MCP read-out using induced charge measurement10.1016/S0168-9002(01)01843-5 ↗
8. A position sensitive detector for SPIDR-a mission to map the cosmic web10.1016/j.nima.2003.08.023 ↗
9. Jagutzki, O., Czasch, A., and Schössler, S. (May, January 29). Performance of a Compact Position-Sensitive Photon Counting Detector with Image Charge Coupling to an Air-Side Anode. Proceedings of the SPIE Defense, Security, and Sensing, Baltimore, MD, USA.
10. Curved focal plane extreme ultraviolet detector array for a EUV camera on CHANG E lander10.1364/OE.23.030755 ↗
11. Han, Z.W., Song, K.F., Zhang, H.J., Yu, M., He, L.P., Guo, Q.F., Wang, X., Liu, Y., and Chen, B. (2020). Photon Counting Imaging with Low Noise and a Wide Dynamic Range for Aurora Observations. Sensors, 20.10.3390/s20205958 ↗
12. Cross-strip anodes for microchannel plate detectors10.1117/12.450071 ↗
13. Overview of spatial and timing resolution of event counting detectors with MicroChannel Plates10.1016/j.nima.2019.162768 ↗
14. Lei, F. (2019). Research on the Key Technology of Single Photon Imaging Based on Position Sensitive Anode. [Ph.D. Dissertation, Xi’an Institute of Optics and Precision Mechanics, University of Chinese Academy Sciences].
15. The quasi-static electromagnetic approximation for weakly conducting media10.1016/S0168-9002(01)01799-5 ↗
16. Calculating and optimizing inter-electrode capacitances of charge division microchannel plate detectors10.1016/j.nima.2016.01.041 ↗
17. Error analysis of CCD-based point source centroid computation under the background light10.1364/OE.17.008525 ↗