New Optical Design Method of Floating Type Collimator for Microscopic Camera Inspection
Source abstract
Abstract
Recently released mobile phone cameras are capable of photographing objects at a fairly close distance. In addition, the field angle from the camera has increased. To measure the resolution of a mobile phone camera, the target must be photographed. To measure the resolution according to the object distance change from a mobile phone camera with a wide field angle, the target size must be large, whereas the target position must be moved. However, the target size cannot be changed. A virtual object for the target was created using a collimator. Moving a part of the lens group constituting the collimator also changes the virtual object distance. If the amount of change in the virtual object distance is large, the resolution of the collimator may also change. Therefore, a collimator that maintains the resolution even when the distance of the virtual object changes is designed as a floating type in which two lens groups move. Therefore, we propose a new floating collimator optical system that can inspect the resolution of mobile phone cameras from infinity to a close range to compensate for aberrations caused by object distance changes.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Image Processing Techniques and Applications · Photoacoustic and Ultrasonic Imaging · Optical measurement and interference techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of IT Convergence, Kumoh National Institute of Technology, Daehakro-61, Gumi 39177, Korea
Department of Optical Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea
Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea
Funding
National Research Foundation of Korea · Grand Information Technology Research Center support program · Business for Cooperative R&D between Industry, Academy, and Research Institute
References (57)
Show source-provided references
1. Optical distance control for a multi focus image in camera phone module assembly10.1007/s12541-011-0107-7 ↗
2. ISO 15529:2010 (2021, July 02). ISO, Optics and Photonics—Optical Transfer Function—Principles of Measurement of Modulation Transfer Function (MTF) of Sampled Imaging System. Available online: https://www.iso.org/standard/56069.html.
3. Mahajan, V.N. (1998). Optical Imaging and Aberrations: Part I: Ray Geometrical Optics, SPIE Press.10.1117/3.265735 ↗
4. Zappe, H. (2010). Fundamentals of Micro-Optics, Cambridge University Press.10.1017/CBO9780511781797 ↗
5. ISO 12233:2017 (2021, July 02). ISO, Photography—Electronic Still Picture Imaging—Resolution and Spatial Frequency Responses. Available online: https://www.iso.org/standard/71696.html.
6. Oh, N.H. (2017). Tele-Convertor Lens System and Apparatus for Evaluating Resolution Using the Same. (No. 10-1776707 B1), KR Patent.
7. Canon Global (2021, June 25). Canon Technology. Available online: https://global.canon/en/technology/rf-2020.html.
8. Osten, W. (2019). Optical Inspection of Microsystems, CRC Press.10.1201/9780429186738 ↗
9. Klingshirn, C.F. (2012). Semiconductor Optics, Springer Science & Business Media.10.1007/978-3-642-28362-8 ↗
10. Pitte, E., Petit, V., and Lecoq, P. (2017). Optical Device, Optical Test Bench and Optical Test Method. (No. 9,719,882B2), U.S. Patent.
11. Park, H.-J., Lee, S.-W., Kang, G.-M., and Moon, H.-G. (1998). Automatic Inspection System for Camera Lenses and Method thereof Using a Line Charge Coupled Device. (Application No. 5,726,746A), U.S. Patent.
12. Rhu, J.-H., and Lee, Y.-H. (2000). Measuring Method of Optics Ability and Apparatus Thereof. (No. 10-0243171B1), KR Patent.
13. Ken, U. (1997). Method and Apparatus for Measuring Diopter of Viewing Lens. (No. 9-243514A), JP Patent.
14. Zawawi, R.B.A., Choi, H., and Kim, J. (2020). High-PSRR Wide-Range Supply-Independent CMOS Voltage Reference for Retinal Prosthetic Systems. Electronics, 9.10.3390/electronics9122028 ↗
15. Development of an Omnidirectional Optical System Based Photoacoustic Instrumentation10.1166/jmihi.2018.2226 ↗
16. Murata, Y. (2007). Eccentricity Measuring Method and Eccentricity Measuring Apparatus. (Application No. 7,307,708B2), U.S. Patent.
17. Wu, C.-L., Angot, L., and Luo, A.-C. (2017). Optical Inspection System and Optical Inspection Method thereof. (Application No. 2017/0177964A1), U.S. Patent.
18. Takeshi, T., and Nobuhiro, M. (1994). Auto-Collimator Device. (No. 6-273267A), JP Patent.
19. Bass, M., Van Stryland, E.W., Williams, D.R., and Wolfe, W.L. (2001). Handbook of Optics, McGraw-Hill Education.
20. Sharma, K.K. (2006). Optics: Principles and Applications, Academic Press.
21. Ray, S. (2002). Applied Photographic Optics, Routledge.10.4324/9780080499253 ↗
22. Hiromitsu, M. (2010). Optical Pickup, Optical Information Reproducing Device and Optically Recorded Information Reproducing Device. (No. 2010-211842A), JP Patent.
23. Lee, C.-W. (1998). Lens Device with Constant Magnification and Variable Focal Length, and Optical Pickup Device Using It. (No. 10-186224A), JP Patent.
24. Mouroulis, P., and Macdonald, J. (1997). Geometrical Optics and Optical Design, Oxford University Press.
25. Iga, K., and Kokubun, Y. (2005). Encyclopedic Handbook of Integrated Optics, CRC Press.10.1201/9781420027815 ↗
26. Statistical Analysis of Focus Adjustment Method for a Floating Imaging System with Symmetric Error Factors10.3807/KJOP.2012.23.5.189 ↗
27. Gross, H., Blechinger, F., and Achtner, B. (2005). Handbook of Optical Systems, Wily-VCH Verlag GmbH & Co.
28. Choi, H., Choe, S.-W., and Ryu, J.-M. (2019). A Macro Lens-Based Optical System Design for Phototherapeutic Instrumentation. Sensors, 19.10.3390/s19245427 ↗
29. Ko, J.H. (2018). Converter Lens System. (No. 10-1862451), KR Patent.
30. Wavelength discrimination (WLD) TOF-PET detector with DOI information10.1088/1361-6560/ab6579 ↗
31. A new positron-gamma discriminating phoswich detector based on wavelength discrimination (WLD)10.1016/j.nima.2019.162631 ↗
32. Seo, S.H., Ryu, J.M., and Choi, H. (2020). Focus-Adjustable Head Mounted Display with Off-Axis System. Appl. Sci., 10.10.3390/app10217931 ↗
33. Photo-Acoustic Applications Using a Highly Focused Macro Lens10.1166/jmihi.2017.1981 ↗
34. Combinational light emitting diode-high frequency focused ultrasound treatment for HeLa cell10.1080/24699322.2017.1379158 ↗
35. Jung, J. (1994). Paraxial Design and Locus Analysis of Zoom Lens System. [Ph. D. Thesis, Kyungnam University].
36. Development of novel adjustable focus head mount display for concurrent image-guided treatment applications10.1080/24699322.2017.1389394 ↗
37. Pedrotti, F.L., and Pedrotti, L.S. (1993). Introduction to Optics, Prentice-Hall Englewood Cliffs.
38. A Cost-effective Light Emitting Diode-acoustic System for Preclinical Ocular Applications
39. Tolerance Analysis of Focus-adjustable Head-mounted Displays
40. Choi, H., Yeom, J.-Y., and Ryu, J.-M. (2018). Development of a Multiwavelength Visible-Range-Supported Opto–Ultrasound Instrument Using a Light-Emitting Diode and Ultrasound Transducer. Sensors, 18.10.3390/s18103324 ↗
41. A Study for an Analytic Conversion between Equivalent Lenses10.3807/KJOP.2012.23.1.017 ↗
42. Choi, H., Ryu, J., and Kim, J. (2016). A Novel Fisheye-Lens-Based Photoacoustic System. Sensors, 16.10.3390/s16122185 ↗
43. Optical Design and Fabrication of a Large Telephoto Zoom Lens with Fixed f/2.8 and Light Autofocus Lens10.3807/JOSK.2015.19.6.629 ↗
44. Choi, H., Jo, J.-Y., and Ryu, J.-M. (2019). A Novel Focal Length Measurement Method for Center-Obstructed Omni-Directional Reflective Optical Systems. Appl. Sci., 9.10.3390/app9112350 ↗
45. Ultrawide-angle optical system design for light-emitting-diode-based ophthalmology and dermatology applications10.3233/THC-199013 ↗
46. Choi, H., Ryu, J.-M., and Yeom, J.-Y. (2017). Development of a Double-Gauss Lens Based Setup for Optoacoustic Applications. Sensors, 17.10.3390/s17030496 ↗
47. Chromatic aberration free reflective mirror-based optical system design for multispectral photoacoustic instruments10.3233/THC-199036 ↗
48. Ullah, M.N., Park, Y., Kim, G.B., Kim, C., Park, C., Choi, H., and Yeom, J.-Y. (2021). Simultaneous Acquisition of Ultrasound and Gamma Signals with a Single-Channel Readout. Sensors, 21.10.3390/s21041048 ↗
49. Development of a low-cost six-axis alignment instrument for flexible 2D and 3D ultrasonic probes10.3233/THC-218008 ↗
50. Choi, H., and Ryu, J. (2019). Design of Wide Angle and Large Aperture Optical System with Inner Focus for Compact System Camera Applications. Appl. Sci., 10.10.3390/app10010179 ↗
51. Choi, H., Choe, S.-w., and Ryu, J. (2021). Optical Design of a Novel Collimator System with a Variable Virtual-Object Distance for an Inspection Instrument of Mobile Phone Camera Optics. Appl. Sci., 11.10.3390/app11083350 ↗
52. Active-beacon-based driver sound separation system for autonomous vehicle applications10.1016/j.apacoust.2020.107549 ↗
53. Shin, S.-H., Yoo, W.-S., and Choi, H. (2019). Development of Public Key Cryptographic Algorithm Using Matrix Pattern for Tele-Ultrasound Applications. Mathematics, 7.10.3390/math7080752 ↗
54. Chaves, J. (2008). Introduction to Nonimaging Optics, CRC press.10.1201/9781420054323 ↗
55. Kim, K.M., Choe, S.-H., Ryu, J.-M., and Choi, H. (2020). Computation of Analytical Zoom Locus Using Padé Approximation. Mathematics, 8.10.3390/math8040581 ↗
56. Yamaji, K. (1967). Progress in Optics, Elsevier.
57. A novel therapeutic instrument using an ultrasound-light-emitting diode with an adjustable telephoto lens for suppression of tumor cell proliferation10.1016/j.measurement.2019.106865 ↗