journal article·2021-10-28Open access

Design of a Remote Monitoring System Based on Optical Sensors to Prevent Medical Accidents during Fluid Treatment

Jae-Kyeong Lee, Ki-Cheol Yoon, Kwang Gi Kim

Applied Sciences· Volume 11· Issue 21

Abstract

It is essential to measure and monitor the intravenous (IV) infusion rate of inpatients. Medical staff monitor the IV infusion rate continually to ensure that a constant value is maintained. Developing an IV infusion monitoring system can help alleviate the workload of medical staff. Therefore, this paper proposes a method based on optical sensors, in conjunction with the Internet of Things, to overcome the challenges of IV therapy. To increase the sensitivity of the system, both optical sensors and load cells are used to compensate for their disadvantages. Our system yielded accuracies of 87.9% and 89.9% under horizontal and vertical motion conditions, respectively. The proposed system can send notifications to nursing stations regarding the residual IV fluid, current infusion rate, and expected end time, which can be monitored remotely by medical staff. Furthermore, this system can help prevent possible medical accidents during fluid treatment.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Intravenous Infusion Technology and Safety · IoT and Edge/Fog Computing · Non-Invasive Vital Sign Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biomedical Engineering, College of Health Science, Gachon University, 191 Hambakmoero, Yeonsu-gu, Incheon 21936, Korea

Medical Devices R&D Center, Gachon University Gil Hospital, 21, 774 Beon-gil, Namdong-daero Namdong-gu, Incheon 21565, Korea

Department of Biomedical Engineering, College of Medicine, Gachon University, 38-13, Dokjom-ro 3, Namdong-gu, Incheon 21565, Korea

Department of Health Sciences and Technology, Gachon Advanced Institute for Health Sciences and Technology (GAIHST), Gachon University, 38-13, 3 Dokjom-ro, Namdong-gu, Incheon 21565, Korea

Funding

Gil Medical Center, Gachon University · GRRC program of Gyeonggi province

References (28)

Show source-provided references
1. COVID-19 and telemedicine: Immediate action required for maintaining healthcare providers well-being10.1016/j.jcv.2020.104345 ↗
2. Design and development of a monitoring and controlling system for multi-intravenous infusion10.1088/1742-6596/1367/1/012075 ↗
3. Guidelines on the insertion and management of central venous access devices in adults10.1111/j.1751-553X.2007.00931.x ↗
4. Errors in the administration of intravenous medications in hospital and the role of correct procedures and nurse experience10.1136/bmjqs-2011-000089 ↗
5. NICE Guideline Draft for Consultation (2013). Intravenous Fluid Therapy in Adults in Hospital—Consultation Document, National Institute for Health and Care Excellence (NICE).
6. The clinical utility of the Fluid Intravenous Alert monitor10.1016/j.jclinane.2016.09.008 ↗
7. Short Text Message Based Infusion Fluid Level Monitoring System
8. Transit Time Difference Flowmeter for Intravenous Flow Rate Measurement Using 1–3 Piezoelectric Composite Transducers10.1109/JSEN.2017.2727340 ↗
9. Bhavasaar, M.K., Nithya, M., Praveena, R., Bhuvaneswari, N.S., and Kalaiselvi, T. (2016, January 15–16). Automated intravenous fluid monitoring and alerting system. Proceedings of the 2016 IEEE Technological Innovations in ICT for Agriculture and Rural Development (TIAR) 2016, Chennai, India.10.1109/TIAR.2016.7801217 ↗
10. Arabelli, R., Rajababu, D., Anuradha, P., and Bernatin, T. (2021). Smart intravenous infusion monitoring and controlling system using Internet of Things. Mater. Today Proc., 1–5.10.1016/j.matpr.2021.01.613 ↗
11. The Internet of Things (IoT): Applications, investments, and challenges for enterprises10.1016/j.bushor.2015.03.008 ↗
12. Wireless sensor network-enabled intravenous infusion monitoring10.1049/iet-wss.2011.0031 ↗
13. Enhanced UHF RFID sensor-tag10.1109/LMWC.2012.2234092 ↗
14. Amano, H., Ogawa, H., Maki, H., Tsukamoto, S., Yonezawa, Y., and Caldwell, W.M. (September, January 28). A remote drip infusion monitoring system employing Bluetooth. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Diego, CA, USA.10.1109/EMBC.2012.6346356 ↗
15. Bluetooth—A new low-power radio interface providing short-range connectivity10.1109/5.889005 ↗
16. Wi-Fi enabled sensors for internet of things: A practical approach10.1109/MCOM.2012.6211498 ↗
17. Setiawan, A.W., Yenas, N., and Welsan, D. (2018, January 21–22). Design and Realization of Low-Cost Wireless Remote Infusion Monitoring System. Proceedings of the 2018 International Seminar on Application for Technology of Information and Communication, Semarang, Indonesia.10.1109/ISEMANTIC.2018.8549820 ↗
18. Center for Devices and Radiological Health, Laser Products and Instruments (2017). U S Food and Drug Administration Home Page, FDA.
19. Elsevier (2021, June 03). Intravenous Therapy: Dose and Flow Rate Calculation—CE Intravenous Therapy: Dose and Flow Rate Calculation—CE. No Box 1. Available online: http://repository.phb.ac.id/770/1/Intravenous-Therapy-Dose-and-Flow-Rate-Calculation-Skill_080520.pdf.
20. Meyer-Arendt, J.R., and Blaker, J.W. (1973). Introduction to Classical and Modern Optics, Pearson Education.10.1119/1.1987159 ↗
21. Optical properties of sodium chloride solution within the spectral range from 300 to 2500 nm at room temperature10.1366/14-07769R ↗
22. Calculate IV Drip Rates—With Ease
23. Hecht, E., and Zajac, A.H. (2003). Optics, Pearson Higher Education, Addison-Wesley. [4th ed.].
24. CROW (2021, February 01). Refractive Index Of Amorphous Polymers. Polymer Properties Database, Available online: https://polymerdatabase.com/polymerphysics/RefIndexTable2.html.
25. Serway, R. (2003). College Physics, Thomson. [6th ed.].
26. Born, M., and Wolf, E. (1999). Principles of Optics, 7th Expand., Cambridge University Press.
27. Dougherty, L., and Lamb, J. (2009). Intravenous Therapy in Nursing Practice, John Wiley & Sons. [2nd ed.].
28. Ubiquitous healthcare monitoring10.1007/s13534-019-00099-8 ↗