journal article·2023-01-24Open access

Factors Affecting Implementation of Radiological Protection Aspects of Imaging in Radiotherapy

Colin John Martin, Sebastien Gros, Tomas Kron, Tim J. Wood, Jenia Vassileva, William Small, Ung Ngie Min

Applied Sciences· Volume 13· Issue 3

Abstract

Dramatic improvements in radiotherapy equipment have allowed radiation fields to be conformed to tumours for more accurate treatment. Successful delivery often requires imaging at every treatment fraction, a method known as image guided radiation therapy (IGRT). But increased X-ray imaging exposes patients to doses that carry risks of inducing second cancers in normal tissues. Therefore, reductions in high-dose treatment margins achieved with IGRT must be balanced against detriments from greater imaging doses. ICRP Task Group 116 has been set up to prepare guidance on radiological protection aspects of IGRT. Factors affecting the optimization of radiological protection are the modalities used, the frequency of imaging, the image acquisition parameters influencing image quality and radiation dose, and the volume of normal tissue included in the images. The Task Group has undertaken two projects: (1) a snapshot survey of radiotherapy imaging practices across six continents, which has shown that use of kV cone beam CT (CBCT) increases with Human Development Index for the country; and (2) a project looking at ways for measuring CBCT doses that could be applied more widely. The results highlight the need for raising awareness of imaging doses, and development of the dose quantities displayed on imaging equipment used in radiotherapy.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Dose and Imaging · Digital Radiography and Breast Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Clinical Physics and Bio-Engineering, Gartnavel Royal Hospital, University of Glasgow, Glasgow G12 0XH, UK

Department of Radiation Oncology, Cardinal Bernardin Cancer Center, Stritch School of Medicine, Loyola University Chicago, Maywood, IL 60153, USA

Department of Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan Street, Melbourne, VIC 3000, Australia

Faculty of Science and Engineering, University of Hull, Cottingham Road, Hull HU6 7RX, UK

Medical Physics Service, Queen’s Centre, Castle Hill Hospital, Hull University Teaching Hospitals NHS Trust, Castle Road, Hull HU16 5JQ, UK

Radiation Protection of Patients Unit, International Atomic Energy Agency, Vienna International Centre, 1400 Vienna, Austria

Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia

References (35)

Show source-provided references
1. Evidence-based estimates of the demand for radiotherapy10.1016/j.clon.2014.10.005 ↗
2. The evolution of radiation therapy in treating cancer Semin10.1016/j.soncn.2018.03.006 ↗
3. International Commission on Radiation Units and Measurements (2021, October 07). Prescribing, Recording and Reporting photon Beam Therapy, ICRU Report 50, ICRU, 1993. Available online: https://journals.sagepub.com/toc/crub/os-26/1.
4. International Commission on Radiation Units and Measurements (2021, August 09). Prescribing, Recording, and Reporting Intensity-Modulated Photon-Beam Therapy (IMRT), ICRU Report 83, ICRU, 2010, Bethesda, USA. Available online: https://journals.sagepub.com/toc/crua/10/1.10.1093/jicru/ndq002 ↗
5. Joiner, M.C., and van der Kogel, A.J. (2019). Basic Clinical Radiobiology, CRC Press. [5th ed.].10.1201/9780429490606 ↗
6. Faculty of Radiation Oncology Position Paper on the use of Image-Guided Radiation Therapy10.1111/1754-9485.12463 ↗
7. Image-guided radiotherapy for pelvic cancers: A review of current evidence and clinical utilization10.1016/j.clon.2020.09.010 ↗
8. Abdominal imaging dose in radiology and radiotherapy—Phantom point dose measurements, effective dose and secondary cancer risk10.1016/j.ejmp.2017.10.019 ↗
9. Imaging dose and secondary cancer risk in image-guided radiotherapy of pediatric patients10.1186/s13014-018-1109-8 ↗
10. Imaging doses and secondary cancer risk from kilovoltage cone-beam CT in radiation therapy10.1097/HP.0b013e318285c685 ↗
11. Imaging practices and radiation doses from imaging in radiotherapy10.1016/j.ejmp.2017.03.012 ↗
12. Imaging Dose, Cancer Risk and Cost Analysis in Image-guided Radiotherapy of Cancers10.1038/s41598-018-28431-9 ↗
13. Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 18010.1002/mp.12824 ↗
14. An international survey of imaging practices in radiotherapy10.1016/j.ejmp.2021.09.004 ↗
15. United Nations, United Nations Development Programme (2022, December 29). Human Development Index (HDI). Available online: http://hdr.undp.org/en/content/human-development-index-hdi.
16. International Commission on Radiological Protection (2016). Radiological Protection in Cone Beam Computed Tomography (CBCT). ICRP Publication 129. Ann. ICRP, 44, 9–127.10.1177/0146645315575485 ↗
17. ACR–ASTRO Practice Parameter for Image-guided Radiation Therapy (IGRT)10.1097/COC.0000000000000697 ↗
18. A survey on table tolerances and couch overrides in radiotherapy10.1120/jacmp.v17i6.6261 ↗
19. IGRT induced dose burden for a variety of imaging protocols at two different anatomical sites10.1016/j.radonc.2011.10.005 ↗
20. Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging dose10.1016/j.radonc.2013.05.034 ↗
21. Comparison of daily versus nondaily image-guided radiotherapy protocols for patients treated with intensity-modulated radiotherapy for head and neck cancer10.1002/hed.23401 ↗
22. Imaging dose from cone beam computed tomography in radiation therapy10.1016/j.ejmp.2015.06.003 ↗
23. The trouble with CTD10010.1118/1.2713240 ↗
24. Concepts for dose determination in flat-detector CT10.1088/0031-9155/53/13/011 ↗
25. Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner10.1088/0031-9155/54/10/012 ↗
26. International Atomic Energy Agency (2011). Status of Computed Tomography Dosimetry for Wide Cone Beam Scanners, IAEA. IAEA Human Health Reports 5.
27. Radiation dosimetry for wide-beam CT scanners: Recommendations of a working party of the Institute of Physics and Engineering in Medicine10.1259/bjr.20130089 ↗
28. International Electrotechnical Commission (2009). Medical Electrical Equipment—Part 2–44: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Computed Tomography, IEC, International Electrotechnical Commission.
29. An assessment of the efficiency of methods for measurement of the computed tomography dose index (CTDI) for cone beam (CBCT) dosimetry by Monte Carlo simulation10.1088/0031-9155/59/21/6307 ↗
30. American Association of Physicists in Medicine (2022, December 29). Comprehensive Methodology for the Evaluation of Radiation Dose in X-ray Computed Tomography. Report of AAPM Task Group 111, 2010. Available online: www.aapm.org/pubs/reports/RPT_111.pdf.
31. American Association of Physicists in Medicine (2022, December 29). The Design and Use of the ICRU/AAPM CT Radiation Dosimetry Phantom: An Implementation of AAPM Report 111. The Report of AAPM Task Group 200, 2014. Available online: www.aapm.org/pubs/reports/RPT_200.pdf.
32. A Monte Carlo investigation of cumulative dose measurements for cone beam computed tomography (CBCT) dosimetry10.1088/0031-9155/60/4/1519 ↗
33. AAPM task group report 302: Surface-guided radiotherapy
34. Variations in size-specific effective dose with patient stature and beam width for kV cone beam CT imaging in radiotherapy10.1088/1361-6498/ac85fa ↗
35. A Monte Carlo study of organ and effective doses of cone beam computed tomography (CBCT) scans in radiotherapy10.1088/1361-6498/aa8f61 ↗